Bureau Veritas Asset Integrity and Reliability Services Pty Limited

Site

Adelaide Inspection

Accreditation No.

1267

Site No.

20035

Date of Accreditation

Address

22A Taminga Street
Regency Park, SA 5010
Australia

bureauveritas.com.au

Contact

Mr R Kot

Availability

Type A Inspection Body

Scope of Accreditation

Withdrawn

ISO/IEC 17020 (2012)

Infrastructure and Asset Integrity

Withdrawn
Service Product Determinant Procedure Limitations
Evaluation of load generating lifting appliances Crane components; Cranes Design verification AS 1418.1 - Sections 5 and 7 and AS 1418.3 - Sections 3 and 5 Limited to structural and mechanical elements only (i.e. excluding hydraulic, electrical and pneumatic components)
Pressure plant, pipelines and equipment - Design verification Boilers; Fired pressure vessels; Gas cylinders; Pressure piping; Unfired pressure vessels Design verification AS/NZS 1200, AS 1210, AS 1228, AS 2030.1 Section 4, AS 3920.1, AS 4041, AS 4343
ASME B31.3, ASME BPVC Section I and Section VIII, Division 1 and 2
EN 286.1, .2, .3, .4,EN 12953 (excluding CE mark provisions), EN 13445 (excluding CE mark provisions), and
NZ Code of Practice - Approved Code of Practice for Pressure Equipment (Excluding Boilers)
PD 5500

Hazard levels: A, B, C, D, E

Pressure plant, pipelines and equipment - In-service inspection Auxiliary vessels; Boilers; Compressed air containing vessels; Fired heaters or convection banks; Pressure piping; Pressure relief devices; Process vessels; Refrigeration and air conditioning vessels; Static low temperature vessels - Below -10 ?C; Static storage vessels; Steam pressure vessels; Storage tanks; Transportable vessels; Vessels with quick actuating closures; Water heaters In-service inspection

AS/NZS 3788
and in-house procedures:
P-3000-IN-0001,
P-3000-IN-0010,
P-3000-IN-0016

Pressure plant, pipelines and equipment - Inspection Pressure relief valves; Storage tanks Witnessing of hydrostatic tests

AS 1180.5,
AS 1210,
AS 1228,
AS 1271,
AS/NZS 3788,
AS 4037 Section 17,
AS 4041
ASME B31.1,
ASME B31.3,
ASME VIII (Division I)
ISO 1402
in-house procedure P-3000-IN-0003

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.