Scope of Accreditation
Withdrawn
ISO/IEC 17025 (2005)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Characterisation of gasesIn-house calibration | Gas blends | Concentration | Comparison measurement by instrumentation | In-house method 05/007 |
Carbon dioxide; carbon monoxide; methane; oxygen by dynamic blending (using a mass flow controller) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of-3% relative |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Concentration | Comparison measurement by instrumentation | In-house method 08/001 |
Carbon dioxide; carbonmonoxide; methane; oxygen by wosthoff gas mixing pump |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of-3% relative |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chemical metrology - Gas analysersincluding on-site calibrations (at customer site - above surface) | Gas analysers; Mine safety and confined space equipment | Concentration | Direct measurement by certified reference material | In-house method 05/006 |
CH4 (Catalytic combustion): 0-100% LEL CH4 (NDIR): 0-5%; 0-100% LEL CO (Electrochemical): 0-1000ppm CO2 (NDIR): 0-5%; 0-100% O2 (Electrochemical): 0-25% O2 (Paramagnetic): 0-100% NO2 (Electrochemical): 0-20ppm H2S (Electrochemical): 0-50ppm |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of-CH4 (Catalytic combustion): 3% relative in the range 0-100% LEL CH4 (NDIR): 3% relative in the ranges 0-5%; and 0-100% LEL CO (Electrochemical): 3% relative in the range 0-1000ppm CO2 (NDIR): 3% relative in the range 0-5%; and 0-100% O2 (Electrochemical): 3% relative in the range 0-25% O2 (Paramagnetic): 3% relative in the range 0-100% NO2 (Electrochemical): 3% relative in the range 0-20ppm H2S (Electrochemical): 3% relative in the range 0-50ppm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mine safety and confined space equipment | Concentration | Direct measurement by certified reference material |
In-house method 05/006 |
CH4 (Catalytic combustion): 0-100% LEL |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of-CH4 (Catalytic combustion): 3%relative in the range 0-100% LEL CH4 (NDIR): 3% relative in therange 0-100% LEL CO (Electrochemical): 3% relative in therange 0-100ppm CO2 (NDIR): 3% relative in therange 0-10% O2 (Electrochemical): 3% relative in the range 0-25% O2 (Paramagnetic): 3% relative in the range 0-100% |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.