Monadelphous Electrical & Instrumentation Pty Ltd

Site

Gladstone Calibration Facility

Accreditation No.

19028

Site No.

21402

Date of Accreditation

Address

47 Benaraby Rd
Gladstone, QLD 4680
Australia

monadelphous.com.au

Contact

Mr Simon Moore P: +61 (07) 48377515

Availability

Services available to external clients

Scope of Accreditation

Withdrawn

Gladstone Calibration Facility

ISO/IEC 17025 (2005)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Vacuum gauges Gauge pressure By pressure calibrator

MSA Test Method 1 - 2008

MSA Test Method 2 - 2008

Capability

With Calibration and Measurement Capability of -

0.06% of reading or 0.012 kPa (whichever is the greater) from -95 kPa to -1.21 kPa
0.03% of reading or 0.012 kPa (whichever is the greater) from 1.21 kPa to 300 kPa
0.06% of reading from 300 kPa to 100 MPa

Mechanical pressure gauges Gauge pressure By pressure calibrator

AS 1349 

MSA Test Method 2 - 2008

From - 95 kPa to 100 MPa

Capability

With Calibration and Measurement Capability of-

0.06% reading or 0.012 kPa (whichever is the greater) from -95 kPa to -1.21 kPa
0.03% reading or 0.012 kPa (whichever is the greater) from 1.21 kPA to 300 kPA
0.06% reading from 300 kPA to 100 MPa

Pressure recorders Gauge pressure By pressure calibrator

MSA Test Method 1 - 2008

From - 95 kPA to 100 MPa

Capability

0.06% reading or 0.012 kPa (whichever is the greater) from -95 kPa to -1.21 kPa
0.03% reading or 0.012 kPa (whichever is the greater) from 1.21 kPA to 300 kPA
0.06% reading from 300 kPA to 100 MPa

Vacuum gauges Gauge pressure By pressure calibrator

AS 1349 

MSA Test Method 2 - 2008

From - 95 to 100 MPa

Capability

With Calibration and Measurement Capability of-

0.06% reading or 0.012 kPa (whichever is the greater) from -95 kPa to -1.21 kPa
0.03% reading or 0.012 kPa (whichever is the greater) from 1.21 kPA to 300 kPA
0.06% reading from 300 kPA to 100 MPa