National Association of Testing Authorities, Australia
Scope of Accreditation
Hi-Quality Quarry Products Pty Ltd
Site
Hi-Quality Quarries Laboratory
Accreditation No.
20641
Site No.
24746
Date of Accreditation
14 Jan 2020
Contact
Mr Craig Evans
P: +61 0467777160
Availability
Services conditionally available to external clients
Scope of Accreditation
Hi-Quality Quarries Laboratory
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of geotechnical and civil construction material - Aggregate contaminants | Aggregates | Organic impurities | Colour test | AS 1141.34; RMS (NSW) Method T260 | |
Clay and fine silt | Settling | AS 1141.33; RMS (NSW) Method T268 | |||
Foreign material in recycled aggregate | Manual classification |
RMS (NSW) Method T276 |
|||
Evaluation of geotechnical and civil construction material - Aggregate properties | Aggregates | Shape | Proportional calliper |
AS 1141.14; RMS (NSW) Method T213 |
|
Bulk density | Compacted | AS 1141.4; RMS (NSW) Method T212 | |||
Particle size distribution | Sieve analysis of material finer than 75 µm |
AS 1141.12; RMS (NSW) Method T203 |
|||
Particle density of coarse aggregate | Weighing-in-water |
AS 1141.6.1 |
|||
Particle density of fine aggregate | Weighing-in-water |
AS 1141.5; RMS (NSW) Method T210 |
|||
Particle size distribution | Sieve analysis | AS 1141.11.1 | |||
Bulk density | Uncompacted |
AS 1141.4; RMS (NSW) Method T211 |
|||
Evaluation of geotechnical and civil construction material - Soil classification | Soils | Plastic limit | Not applicable | AS 1289.3.2.1; RMS (NSW) Method T109;TfNSW T109;TfNSW T105; | |
Liquid limit | Casagrande four point; Casagrande one point | AS 1289.3.1.1, AS 1289.3.1.2; RMS (NSW) Method T108;TfNSW T108;TfNSW T105; | |||
Fine particles in road materials | Not applicable |
AS 1141.19; RMS (NSW) Method T107;TfNSW T107; |
|||
Linear shrinkage | Not applicable | AS 1289.3.4.1; RMS (NSW) Method T113;TfNSW T113; | |||
Sieve analysis | Not applicable |
AS 1289.3.6.1 |
|||
Moisture content | Hot plate | AS 1289.2.1.6; RMS (NSW) Method T121 | |||
Moisture content | Drying oven | AS 1289.2.1.1; RMS (NSW) Method T120 | |||
Plasticity index | Cone |
AS 1289.3.3.1 |
|||
Evaluation of geotechnical and civil construction material - Soil compaction characteristics | Soils | Dry density/moisture content relationship | Standard compactive effort |
AS 1289.5.1.1; RMS (NSW) Method T111, RMS (NSW) Method T130 |
|
Dry density/moisture content relationship | Modified compactive effort | AS 1289.5.2.1; RMS (NSW) Method T112 | |||
Assignment of optimum moisture content/maximum dry density (OMC/MDD) | Not applicable |
AS 1289.5.4.2 |
|||
Evaluation of geotechnical and civil construction material - Soil natural contaminants | Soils | Acidity | pH | AS 1289.4.3.1; RMS (NSW) Method T123 | |
Evaluation of geotechnical and civil construction material - Soil pre-treatment | Soils | Soil pre-treatment | Accelerated weathering pre-treatment |
RMS (NSW) Method T103;TfNSW T103;TfNSW T105; |
|
Soil pre-treatment | Not applicable |
AS 1289.1.1; RMS (NSW) Method T102;TfNSW T102;TfNSW T105;, RMS (NSW) Method T105 |
|||
Sample collection | Aggregates | Not applicable | Aggregate from a stockpile | AS 1141.3.1 | |
Soils | Not applicable | Disturbed soil sampling from a stockpile | AS 1289.1.2.1 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20641
Site No.
24746
Print date
19 Aug 2022
END OF SCOPE