National Association of Testing Authorities, Australia
Scope of Accreditation
Instrulabs Pty Ltd
Site
Instrulabs Pty Ltd
Accreditation No.
1943
Site No.
1936
Date of Accreditation
Contact
Availability
Services available to external clients
Scope of Accreditation
Withdrawn
ISO/IEC 17025 (2005)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Acoustical metrology - Acoustic equipment | Band pass filters | Frequency response | By methods of AS/NZS 4476 |
for relative attenuation up to 80 dB |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.7 dB for relative attenuation up to 80 dB |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dose meters for sound | Electrical response; Frequency response; Noise exposure/dose | By methods of AS 2399 |
63 Hz to 8 kHz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Periodic calibration of Cirrus Research dosebadge Noise dosimeters and personal sound exposure meters With Calibration and Measurement Capability of - 0.11 dB from 63 Hz to 125 Hz 0.09 dB from above 250 Hz to 2 kHz 0.12 dB from above 4 kHz to 8 kHz 0.12 dB for electrical tests 5% for noise dose |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sound level meters | Frequency response | By methods of AS 1259.1; By methods of AS 1259.2; By methods of IEC 61672-3 |
31.5 Hz to 12.5 kHz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.13 dB from 31.5 Hz to below 8 kHz 0.15 dB at 8 kHz 0.19 dB at 12.5 kHz (AS 1259) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electrical response | By methods of AS 1259.1; By methods of AS 1259.2; By methods of IEC 61672-3 |
AS 1259.1: 1990 AS 1259.2: 1990 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.1 dB |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electrical response | By methods of IEC 61672-3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.12 dB |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Acoustical metrology - Acoustic equipmentincluding on site calibrations | Audiometers | Sound pressure level | By methods of AS/IEC 60645.1 | AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. |
Type 4 Screening Audiometers only (including calibration in the field) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.23 dB or sound pressure level between 500 Hz and 8 kHz |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Total harmonic distortion | By methods of AS/IEC 60645.1 | AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. | Type 4 Screening Audiometers only (including calibration in the field) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 0.7% for THD+Noise |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency response | By methods of AS/IEC 60645.1 | AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. | Type 4 Screening Audiometers only (including calibration in the field) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.11% for Frequency |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Acoustical metrology - Acoustic standards and reference equipment | Acoustic calibrators - Multi frequency; Acoustic calibrators - Single frequency | Frequency | By methods of AS/IEC 60942 | AS/IEC 60942 Annex B - Periodic Tests | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.05% for frequency |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Distortion | By methods of AS/IEC 60942 | AS/IEC 60942 Annex B - Periodic Tests | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.8% for total harmonic distortion |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure sensitivity | By methods of AS/IEC 60942 | AS/IEC 60942 Annex B - Periodic Tests |
for sound pressure level at nominal 1 kHz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.2 dB for sound pressure level at nominal 1 kHz |
ISO/IEC 17025 (2005)
Manufactured Goods
|
|||||
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Acoustic performance evaluation of products | Acoustic enclosures and booths | Sound absorption; Sound insulation; Sound pressure level; Sound transmission |
WorkCover WA Acoustical Environment for Audiometry |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
1943
Site No.
1936
Print date
03 Dec 2023