Keysight Technologies Australia Pty Ltd

Site

Keysight Technologies Australia Pty Ltd

Accreditation No.

1135

Site No.

22533

Date of Accreditation

Address

745 Springvale Rd
Mulgrave, VIC 3170
Australia

keysight.com

Contact

Mr Keith Baucke P: +61 1800225574

Availability

Services available to external clients

Scope of Accreditation

Withdrawn

Keysight Technologies Australia Pty Ltd

ISO/IEC 17025 (2005)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators AC current; AC voltage; DC current; DC voltage; Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

D.C voltage

5 μV/V + 0.2 μV up to 1 V
3 μV/V from 1 V to 1000 V
7 μV/V from 1000 V to 1020 V

A.C. voltage

From 1 mV to 10 mV
380 μV/V at 10 Hz to 20 kHz
450 μV/V at 30 kHz to 50 kHz
720 μV/V at 100 kHz
950 μV/V at 300 kHz to 500 kHz
From 10 mV to 0.1 V
200 μV/V at 10 Hz to 20 kHz
300 μV/V at 30 kHz to 50 kHz
500 μV/V at 100 kHz
700 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 0.1 V to 1 V
140 μV/V at 10 Hz to 20 kHz
220 μV/V at 30 kHz to 50 kHz
420 μV/V at 100 kHz
710 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 1 V to 10 V
42 μV/V at 10 Hz to 30 Hz
28 μV/V at 40 Hz to 30 kHz
43 μV/V at 50 kHz to 100 kHz
120 μV/V at 300 kHz
240 μV/V at 500 kHz
650 μV/V at 1MHz
From 10 V to 100 V
420 μV/V at 10 Hz to 30 Hz
300 μV/V at 40 Hz to 30 kHz
600 μV/V at 50 kHz
300 μV/V at 100 kHz
950 μV/V at 300 kHz
2.2 mV/V at 500 kHz
6.2 mV/V at 1 MHz
From 100 V to 700 V
48 μV/V at 10 Hz to 55 Hz
34 μV/V at 300 Hz to 30 kHz
41 μV/V at 50 kHz
77 μV/V at 100 kHz
280 μV/V at 200 kHz
From 700 V to 1000 V
43 μV/V at 40 Hz to 1 kHz
54 μV/V at 5 kHz
45 μV/V at 8 kHz
46 μV/V at 10 kHz
54 μV/V at 20 kHz
86 μV/V at 30 kHz

D.C. current

24 μA/A from 1 μA to 1 mA
13 μA/A from 1 mA to 0.1 A
17 μA/A from 0.1 A to 1 A
29 μA/A from 1 A to 10 A
67 μA/A from 10 A to 20 A
220 μA/A at 20 A

A.C. current

From 0.1 mA to 1 mA
150 μA/A at 10 Hz to 30 Hz
110 μA/A at 40 Hz to 1 kHz
560 μA/A at 5 kHz
2200 μA/A at 10 kHz
From 1 mA to 10 mA
140 μA/A at 10 Hz to 30 Hz
95 μA/A at 40 Hz to 1 kHz
150 μA/A at 5 kHz
310 μA/A at 10 kHz
From 10 mA to 100 mA
130 μA/A at 10 Hz to 30 Hz
88 μA/A at 40 Hz to 1 kHz
130 μA/A at 5 kHz
300 μA/A at 10 kHz
From 0.1 A to 1 A
140 μA/A at 10 Hz to 30 Hz
89 μA/A at 40 Hz to 1 kHz
140 μA/A at 5 kHz
410 μA/A at 10 kHz
From 1 A to 10 A
200 μA/A at 10 Hz to 30 Hz
130 μA/A at 40 Hz to 1 kHz
250 μA/A at 5 kHz
300 μA/A at 10 kHz
From 10 A to 20 A
280 μA/A at 10 Hz to 30 Hz
230 μA/A at 40 Hz to 1 kHz
300 μA/A at 5 kHz
390 μA/A at 10 kHz
 At 20 A
310 μA/A at 20 A at 45 Hz to 1 kHz
1000 μA/A at 20 A at 5 kHz

Resistance

15 μΩ/Ω + 20 μΩ up to 1.9 Ω
9 μΩ/Ω from 1.9 Ω to19 Ω
7 μΩ/Ω from 19 Ω to 190 Ω
4 μΩ/Ω from 190 Ω to 19 kΩ
7 μΩ/Ω from 19 kΩ to 190 kΩ
13 μΩ/Ω from 190 kΩ to 1.9 MΩ
24 μΩ/Ω from 1.9 MΩ to 19 MΩ
95 μΩ/Ω from 19 MΩ to 100 MΩ
630 μΩ/Ω from 100 MΩ to 290 MΩ
1.2 mΩ/Ω from 400 MΩ to 640 MΩ
1.8 mΩ/Ω from 640 MΩ to 1100 M Ω

DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters AC current Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
Multiple turn clamp on meters
0.5% from 20 A to 1 000 A

Ammeters; Appliance testers DC current Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
Multiple turn clamp on meters
0.2% from 20 A to 1000 A
Ground bond current testers
1.73% + 0.35 A up to 25 A
1.73% + 0.7 A from 25 A to 30 A

Ammeters; Appliance testers; Data recorders; Insulation resistance test equipment; Phase angle meters; Power analysers; Power supplies; Residual current circuit breaker testers; Residual current devices (RCD) testers AC current; DC current Comparison with a reference standard

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

D.C.

24 μA/A from 1 μA to 220 μA
13 μA/A from 220 μA to 22 mA
18 μA/A from 22 mA to 220 mA
30 μA/A from 220 mA to 2.2 A
78 μA/A from 2.2 A to 11 A
220 μA/A from 11 A to 20 A

A.C.

From 1 μA to 220 μA
400 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
400 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz
From 220 μA to 220 mA
300 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
300 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz


From 220 mA to 2.2 A
300 μA/A at 20 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
7100 μA/A from 5 kHz to 10 kHz
From 2.2 A to 11 A
400 μA/A at 40 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
3700 μA/A from 5 kHz to 10 kHz
From 11 A to 20 A
500 μA/A at 45 Hz to 1 kHz
1500 μA/A from 1 kHz to 5 kHz

Appliance testers; Data recorders; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Phase angle meters; Power analysers; Power supplies; Residual current circuit breaker testers; Residual current devices (RCD) testers Resistance Comparison with a reference standard

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

77 μΩ/Ω + 20 μΩ up to 1 Ω
50 μΩ/Ω from 1 Ω to 1.9 Ω
25 μΩ/Ω from 1.9 Ω to 10 Ω
45 μΩ/Ω from 10 Ω to 19 Ω
21 μΩ/Ω from 19 Ω to 100 Ω
15 μΩ/Ω from 100 Ω to 100 kΩ
19 μΩ/Ω from 100 kΩ to 190 kΩ
24 μΩ/Ω from 190 kΩ to 1 MΩ
120 μΩ/Ω from 1 MΩ to 1.9 MΩ
74 μΩ/Ω from 1.9 MΩ to 10 MΩ
640 μΩ/Ω from 10 MΩ to 19 MΩ
600 μΩ/Ω from 19 MΩ to 100 MΩ
6.1 mΩ/Ω from 100 MΩ to 1 GΩ

Appliance testers; Data recorders; Digital multimeters (DMM); Insulation resistance test equipment; Phase angle meters; Power analysers; Power supplies; Residual current circuit breaker testers; Residual current devices (RCD) testers; Voltmeters AC voltage; DC voltage Comparison with a reference standard

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

D.C.

10 μV/V + 0.4 μV from 1 μV to 0.22 V
6 μV/V from 0.22 V to 2.2 V
5 μV/V from 2.2 V to 22 V
8 μV/V from 22 V to 1000 V

A.C.

From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz

Appliance testers; Insulation resistance test equipment AC voltage; Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
Insulation resistance testers up to 1 kV
0.60% up to 100 kΩ
0.12% from 100 kΩ to 100 MΩ
0.51% from 100 MΩ to 1GΩ
0.77% from 1 GΩ to 10 GΩ
Insulation resistance testers from 1 kV to 5 kV
0.77% up to 10 GΩ
3.0% from 10 GΩ to 100 GΩ
4.7% from 100 GΩ to 9 TΩ
Insulation resistance testers from 5 kV to 10 kV
1.9% up to 10 GΩ
3.0% from 10 GΩ to 100 GΩ
4.7% from 100 GΩ to 9 TΩ
Output voltage for insulation resistance up to 10 kV
0.22% up to 1 kV
0.65% from 1 kV to 10 kV

Appliance testers; LCR meters; Ohm meters Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
0.01% from 1 mΩ to 100 mΩ

LCR meters Capacitance; Dissipation factor; Inductance; Resistance Comparison with a reference standard

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

Inductance

4.2 mH/H at 100 μH to 300 μH at 1 kHz
3.0 mH/H from 300 μH to 3 mH at 1 kHz
2.2 mH/H from 3 mH to 10 H at 1 kHz
Capacitance

0.7 fF/pF for 1 pF at 1 kHz
4.5 fF/pF for 1 pF from 1 kHz to 1 MHz
15.2 fF/pF for 1 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.4 fF/pF for 10 pF & 100 pF at 1 kHz
0.9 fF/pF for 10 pF & 100 pF from 1 kHz to 1 MHz
2.5 fF/pF for 10 pF & 100 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 1 nF at 1 kHz to 1 MHz
6.3 pF/nF for 1 nF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 10 nF at 20 Hz to 10 kHz
1.9 pF/nF for 10 nF from 10 kHz to 100 kHz
0.5 pF/nF for 100 nF at 20 Hz to 1 kHz
1.3 pF/nF for 100 nF from 1 kHz to 10 kHz
3.5 pF/nF for 100 nF from 10 kHz to 100 kHz
1.0 nF/μF for 1 μF from 20 Hz to 10 kHz
Dissipation Factor
0.0005 for 1 pF at 1.6 kHz to 1 MHz
0.0012 for 1 pF from 1 MHz to 13 MHz
0.0004 for 10 pF at 200 Hz to 1 MHz
0.0011 for 10 pF from 1 MHz to 13 MHz
0.0049 for 100 pF at 20 Hz to 1 kHz
0.0005 for 100 pF from 1 kHz to 1 MHz
0.0013 for 100 pF from 1 MHz to 13 MHz
0.0003 for 10 nF at 1 kHz
0.0004 for 100 nF at 1kHz
0.0005 for 1000 pF at 1kHz
A.C. Resistance
220 μΩ for 0.1 Ω at 1 kHz
2.9 mΩ for 1 Ω from 5 Hz to 1 MHz
2.2 mΩ for 10 Ω from 1 MHz to 13 MHz
190 mΩ for 100 Ω from 5 Hz to 1 MHz
510 mΩ for 100 Ω from 1 MHz to 13 MHz
2.8 Ω for 1 kΩ from 5 Hz to 1 MHz
4.2 Ω for 1 kΩ from 1 MHz to 13 MHz
28 Ω for 10 kΩ from 5 Hz to 1 MHz
550 Ω for 100 kΩ from 5 Hz to 1 MHz

Capacitance Direct measurement against a reference standard

0.001 μF to 10 μF

Capability

with Calibration and Measurement Capability of -
3% from 0.001 μF to 10 μF

Phase angle meters Phase angle Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
0.15º at 50 Hz up to 240 V and 3 A

Watt meters Active power; Power factor Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

DC power wattmeters 0.15%
AC power wattmeters 0.20%
up to 600 V and 20 A, DC to 50 Hz (to a maximum of 12 kW) at PF = 1 only

DC and low frequency electrical metrology - Electrical standards AC/DC transfer instruments Voltage AC-DC difference Direct measurement against a reference standard

Capability

Thermal converters with BNC input connectors
with Calibration and Measurement Capability of -

0.18 % from 0.5 V to 3.0 V and from 1 kHz to 1 MHz
0.26 % from 0.5 V to 3.0 V at 5, 10 & 30 MHz
0.42 % from 0.5 V to 3.0 V at 50 MHz
0.64 % from 0.5 V to 3.0 V at 70 MHz & 80 MHz

Conductance boxes; Current shunts; Precision resistors; Resistance boxes Resistance Direct measurement against a reference standard

Capability

Including DC shunts up to 100 A
with Calibration and Measurement Capability of -
0.01% from 1 mΩ to 100 mΩ

Conductance boxes; Precision resistors; Resistance boxes Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
at decade values of -

16 μΩ/Ω at 1 Ω
7 μΩ/Ω at 10 Ω
8 μΩ/Ω at 100 Ω
5 μΩ/Ω at 1 kΩ
3 μΩ/Ω at 10 kΩ
6 μΩ/Ω at 100 kΩ
9 μΩ/Ω at 1 MΩ
60 μΩ/Ω at 10 MΩ
230 μΩ/Ω at 100 MΩ
3.2 mΩ/Ω at 1 GΩ
within the ranges of -
77 μΩ/Ω + 5 μΩ up to 1 Ω
25 μΩ/Ω from 1 Ω to 10 Ω
22 μΩ/Ω from 10 Ω to 100 Ω
13 μΩ/Ω from 100 Ω to 100 kΩ
20 μΩ/Ω from 100 kΩ to 1 MΩ
62 μΩ/Ω from 1 MΩ to 10 MΩ
790 μΩ/Ω from 10 MΩ to 100 MΩ
5.2 mΩ/Ω from 100 MΩ to 1 GΩ
AC Resistance
220 μΩ for 0.1 Ω at 1 kHz
2.9 mΩ for 1 Ω at 1 kHz to 1 MHz
19 mΩ for 10 Ω at 1 kHz to 1 MHz
190 mΩ for 100 Ω at 1 kHz to 1 MHz
2.8 Ω for 1 kΩ at 1 kHz to 1 MHz
28 Ω for 10 kΩ at 1 kHz to 1 MHz
550 Ω for 100 kΩ at 1 kHz to 100 kHz

Inductors Inductance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

4.2 mH/H at 100 μH to 300 μH at 1 kHz
3.0 mH/H from 300 μH to 3 mH at 1 kHz
2.2 mH/H from 3 mH to 10 H at 1 kHz 

Precision capacitors Capacitance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

0.5fF for 1 pF at 1 kHz
5 fF for 10 pF, at 1 kHz
50 fF for 100 pF at 1 kHz
4.5 fF for 1 pF at 1 MHz
8 fF for 10 pF at 1 MHz
80 fF for 100 pF at 1 MHz
0.6 pF for 1000 pF at 1 kHz
0.9 pF for 1000 pF at 1 MHz
5 pF for 0.01 μF at 120 Hz to 1 kHz
50 pF for 0.1 μF at 120 Hz to 1 kHz
7 pF for 0.01 μF at 10 kHz
17 pF for 0.01 μF at 100 kHz
0.1 nF for 0.1 μF at 10 kHz
0.3 nF for 0.1 μF at 100 kHz
0.7 nF for 1 μF at 120 Hz
0.5 nF for 1 μF at 1 kHz
0.9 nF for 1 μF at 10 kHz

Voltage standards - E.M.F. reference devices Voltage Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

2.5 μV at 1 V nominal
25 μV at 10 V nominal

DC and low frequency electrical metrology - High-voltage/high-current standards and equipment High voltage test sets Current; Voltage Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
Output high voltage for DC test sets
0.68% from 1 kV to 40 kV
Output high voltage for AC test sets at 50 Hz
1.0% up to 2 kV
 0.8% from 2 kV to 28 kV

High frequency electrical metrology - Communications, electromagnetic field strength and EMC test equipment Amplifiers; Attenuators; Communications systems; Data transmission measuring equipment; Electrical noise and interference measuring equipment; Electromagnetic field hazard meters and warning indicators; Harmonic emission compliance test systems; Impedance and reflection measuring equipment; Line impedance stabilisation networks (LISN); Line transmission measuring equipment; Power measuring equipment; Radio transmission measuring equipment; Spectrum analysers; Waveguide and coaxial components Attenuation; Insertion loss; Internal reference impedance resistance Comparison with a reference standard

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

For attenuation above 40 dB using a network analyser, the
laboratory's capability is limited to step attenuators or similar devices,
such that individual elements can be selectively measured

Using measuring receiver systems

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

Using VNA systems

From 5 Hz to 45 MHz
0.14 dB from 0 dB to 10 dB
0.14 dB from 10 dB to 30 dB
0.14 dB from 30 dB to 40 dB
0.14 dB from 40 dB to 70 dB
0.14 dB from 70 dB to 90 dB
0.14 dB from 90 dB to 100 dB
0.14 dB from 100 dB to 120 dB
From 45 MHz to 2 GHz
0.04 dB from 0 dB to 10 dB
0.09 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.33 dB from 40 dB to 70 dB
0.40 dB from 70 dB to 90 dB
0.43 dB from 90 dB to 100 dB
0.63 dB from 100 dB to 120 dB
From 2 GHz to 18 GHz
0.08 dB from 0 dB to 10 dB
0.08 dB from 10 dB to 30 dB
0.10 dB from 30 dB to 40 dB
0.18 dB from 40 dB to 70 dB
0.26 dB from 70 dB to 90 dB
0.26 dB from 90 dB to 100 dB
0.35 dB from 100 dB to 120 dB
From 18 GHz to 26.5 GHz
0.17 dB from 0 dB to 10 dB
0.18 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.59 dB from 40 dB to 70 dB
0.76 dB from 70 dB to 90 dB
0.78 dB from 90 dB to 100 dB
1.0 dB from 100 dB to 120 dB
From 26.5 GHz to 40 GHz
0.17 dB from 0 dB to 10 dB
0.25 dB from 10 dB to 30 dB
0.48 dB from 30 dB to 40 dB
0.91 dB from 40 dB to 70 dB
1.09 dB from 70 dB to 90 dB
1.2 dB from 90 dB to 100 dB
1.6 dB from 100 dB to 120 dB
From 40 GHz to 50 GHz
0.29 dB from 0 dB to 10 dB
0.66 dB from 10 dB to 30 dB
1.8 dB from 30 dB to 40 dB
2.8 dB from 40 dB to 70 dB
3.2 dB from 70 dB to 90 dB
3.5 dB from 90 dB to 100 dB
5.0 dB from 100 dB to 120 dB

Internal reference impedance resistance; Reflection coefficient Comparison with a reference standard; Direct measurement by electrical input

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -

From 20 Hz to 45 MHz
(± 0.005 to ± 0.007) lin and (± 2.1 to ± 180) deg from (0.001 to 0.01) lin
(± 0.006 to ± 0.008) lin and (± 2.8 to ± 3.8) deg from (0.01 to 0.1) lin
(± 0.006 to ± 0.019) lin and (± 1.1 to ± 3.8) deg from (0.1 to 1.0) lin
From 45 MHz to 18 GHz
(± 0.005 to ± 0.029) lin and (± 24.0 to ± 180) deg from (0.001 to 0.01) lin
(± 0.005 to ± 0.029) lin and (± 7.3 to ± 29) deg from (0.01 to 0.1) lin
(± 0.005 to ± 0.029) lin and (± 1.1 to ± 9.9) deg from (0.1 to 1.0) lin
From 18 GHz to 26.5 GHz
(± 0.011 to ± 0.028) lin and (± 12.4 to ± 180) deg from (0.001 to 0.01) lin
(± 0.011 to ± 0.028) lin and (± 14.0 to ± 15.5) deg from (0.01 to 0.1) lin
(± 0.011 to ± 0.028) lin and (± 8.4 to ± 11.0) deg(0.1 to 1.0) lin
From 26.5 GHz to 50 GHz
(± 0.016 to ± 0.035) lin and (± 54 to ± 180) deg from (0.001 to 0.01) lin
(± 0.016 to ± 0.035) lin and (± 17.8 to ± 180) deg from (0.01 to 0.1) lin
(± 0.016 to ± 0.035) lin and (± 9.7 to ± 12.3) deg from (0.1 to 1.0) lin

Communications systems; Data transmission measuring equipment; Electrical noise and interference measuring equipment; Line transmission measuring equipment; Power measuring equipment; Radio transmission measuring equipment; Spectrum analysers Frequency Comparison with a reference standard; Comparison with a reference standard by differential measurement; Comparison with a reference standard by substitution measurement; Direct measurement by electrical input

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
Frequency characteristics

5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Frequency standards
5 parts in 1012 from 1 mHz to 10 MHz in main laboratory
7 parts in 1011 from 1 mHz to 10 MHz in VOSCAL laboratory

Data transmission measuring equipment Voltage deviation Comparison with a reference standard by differential measurement

Capability

Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of --
0.13 % from 1 mV to 4 V

Power measuring equipment Power Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

including calibrations at VOSCAL mobile facility

from +20 dBm to -30 dBm at the reference power level appropriate to the sensor
absolute power calibration factor 

0.37 % at 1 mW and 50 MHz
1.3 % from 9 kHz to 18 GHz
2.0 % from 18 GHz to 26.5 GHz
2.3 % from 26.5 GHz to 40 GHz
3.7 % from 40 GHz to 50 GHz

Spectrum analysers Frequency To be determined

Frequency characteristics

From 1 Hz to 50 GHz

Output characteristics

From 5 Hz to 50 GHZ

Capability

with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

In-situ calibration of communications, electromagnetic field strength and EMC test equipment Amplifiers; Attenuators; Waveguide and coaxial components Attenuation To be determined

From 5 Hz to 50 GHz

For attenuation above 40 dB using a network analyser, the
laboratory's capability is limited to step attenuators or similar devices,
such that individual elements can be selectively measured

Capability

with Calibration and Measurement Capability of -

Using measuring receiver systems

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

Using VNA systems

From 5 Hz to 45 MHz
0.14 dB from 0 dB to 10 dB
0.14 dB from 10 dB to 30 dB
0.14 dB from 30 dB to 40 dB
0.14 dB from 40 dB to 70 dB
0.14 dB from 70 dB to 90 dB
0.14 dB from 90 dB to 100 dB
0.14 dB from 100 dB to 120 dB
From 45 MHz to 2 GHz
0.04 dB from 0 dB to 10 dB
0.09 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.33 dB from 40 dB to 70 dB
0.40 dB from 70 dB to 90 dB
0.43 dB from 90 dB to 100 dB
0.63 dB from 100 dB to 120 dB
From 2 GHz to 18 GHz
0.08 dB from 0 dB to 10 dB
0.08 dB from 10 dB to 30 dB
0.10 dB from 30 dB to 40 dB
0.18 dB from 40 dB to 70 dB
0.26 dB from 70 dB to 90 dB
0.26 dB from 90 dB to 100 dB
0.35 dB from 100 dB to 120 dB
From 18 GHz to 26.5 GHz
0.17 dB from 0 dB to 10 dB
0.18 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.59 dB from 40 dB to 70 dB
0.76 dB from 70 dB to 90 dB
0.78 dB from 90 dB to 100 dB
1.0 dB from 100 dB to 120 dB
From 26.5 GHz to 40 GHz
0.17 dB from 0 dB to 10 dB
0.25 dB from 10 dB to 30 dB
0.48 dB from 30 dB to 40 dB
0.91 dB from 40 dB to 70 dB
1.09 dB from 70 dB to 90 dB
1.2 dB from 90 dB to 100 dB
1.6 dB from 100 dB to 120 dB
From 40 GHz to 50 GHz
0.29 dB from 0 dB to 10 dB
0.66 dB from 10 dB to 30 dB
1.8 dB from 30 dB to 40 dB
2.8 dB from 40 dB to 70 dB
3.2 dB from 70 dB to 90 dB
3.5 dB from 90 dB to 100 dB
5.0 dB from 100 dB to 120 dB

Communications systems Frequency

Frequency characteristics

From 1 Hz to 50 GHz

Capability

with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Data transmission measuring equipment Transmission coefficient; Voltage deviation

From 1 Hz to 50 GHz

From 1 mV to 4 V

Capability

with Calibration and Measurement Capability of -

5 parts in 10-12 from 1 Hz to 12.4 GHz
2 parts in 10-10 from 12.4 GHz to 46 GHz
8 parts in 10-8 from 46 GHz to 50 GHz
0.13 % from 1 mV to 4 V

Impedance and reflection measuring equipment; Waveguide and coaxial components Internal reference impedance resistance

From 20 Hz to 18 GHz and form (0.001 to 1.0) lin

Capability

with Calibration and Measurement Capability of -

From 20 Hz to 45 MHz
(0.001 to 0.01) lin
(± 0.005 to ± 0.007) lin and (± 2.1 to ± 180) deg
(0.01 to 0.1) lin
(± 0.006 to ± 0.008) lin and (± 2.8 to ± 3.8) deg
(0.1 to 1.0) lin
(± 0.006 to ± 0.019) lin and (± 1.1 to ± 3.8) deg
From 45 MHz to 18 GHz
(0.001 to 0.01) lin
(± 0.005 to ± 0.029) lin and (± 24.0 to ± 180) deg
(0.01 to 0.1) lin
(± 0.005 to ± 0.029) lin and (± 7.3 to ± 29) deg
(0.1 to 1.0) lin
with least uncertainties of measurement of:
(± 0.005 to ± 0.029) lin and (± 1.1 to ± 9.9) deg
From 18 GHz to 26.5 GHz
(0.001 to 0.01) lin
(± 0.011 to ± 0.028) lin and (± 12.4 to ± 180) deg
(0.01 to 0.1) lin
(± 0.011 to ± 0.028) lin and (± 14.0 to ± 15.5) deg
(0.1 to 1.0) lin
(± 0.011 to ± 0.028) lin and (± 8.4 to ± 11.0) deg
From 26.5 GHz to 50 GHz
(0.001 to 0.01) lin
(± 0.016 to ± 0.035) lin and (± 54 to ± 180) deg
(0.01 to 0.1) lin
(± 0.016 to ± 0.035) lin and (± 17.8 to ± 180) deg
(0.1 to 1.0) lin
(± 0.016 to ± 0.035) lin and (± 9.7 to ± 12.3) deg

Power measuring equipment Power

From +20 dBm to -30 dBm

At the reference power level appropriate to the sensor 

Capability

with Calibration and Measurement Capability of -

absolute power calibration factor
0.37 % at 1 mW and 50 MHz
1.3 % from 9 kHz to 18 GHz
2.0 % from 18 GHz to 26.5 GHz
2.3 % from 26.5 GHz to 40 GHz
3.7 % from 40 GHz to 50 GHz

Spectrum analysers Frequency To be determined

Frequency characteristics

From 1 Hz to 50 GHz

Output characteristics

From 5 Hz to 50 GHZ

Capability

with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

In-situ calibration of electrical instrument calibrators Instrument calibrators AC current; AC voltage; DC current; DC voltage; Resistance Direct measurement against a reference standard

D.C voltage

Up to 1 V and from 1 V to 1020 V

A.C. current

From 1 mV to 1000 V at 10 Hz to 1 MHz

D.C. current

From 1μA to 20 A

A.C. current

From 0.1 mA to 20 A and at 10 Hz to 10 kHz

Resistance

Up to 1.9 Ω and from 1.9 Ω to 1100 MΩ

Capability

with Calibration and Measurement Capability of -

D.C voltage

5 μV/V + 0.2 μV up to 1 V
3 μV/V from 1 V to 1000 V
7 μV/V from 1000 V to 1020 V

A.C. voltage

From 1 mV to 10 mV
380 μV/V at 10 Hz to 20 kHz
450 μV/V at 30 kHz to 50 kHz
720 μV/V at 100 kHz
950 μV/V at 300 kHz to 500 kHz
From 10 mV to 0.1 V
200 μV/V at 10 Hz to 20 kHz
300 μV/V at 30 kHz to 50 kHz
500 μV/V at 100 kHz
700 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 0.1 V to 1 V
140 μV/V at 10 Hz to 20 kHz
220 μV/V at 30 kHz to 50 kHz
420 μV/V at 100 kHz
710 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 1 V to 10 V
42 μV/V at 10 Hz to 30 Hz
28 μV/V at 40 Hz to 30 kHz
43 μV/V at 50 kHz to 100 kHz
120 μV/V at 300 kHz
240 μV/V at 500 kHz
650 μV/V at 1MHz
From 10 V to 100 V
420 μV/V at 10 Hz to 30 Hz
300 μV/V at 40 Hz to 30 kHz
600 μV/V at 50 kHz
300 μV/V at 100 kHz
950 μV/V at 300 kHz
2.2 mV/V at 500 kHz
6.2 mV/V at 1 MHz
From 100 V to 700 V
48 μV/V at 10 Hz to 55 Hz
34 μV/V at 300 Hz to 30 kHz
41 μV/V at 50 kHz
77 μV/V at 100 kHz
280 μV/V at 200 kHz
From 700 V to 1000 V
43 μV/V at 40 Hz to 1 kHz
54 μV/V at 5 kHz
45 μV/V at 8 kHz
46 μV/V at 10 kHz
54 μV/V at 20 kHz
86 μV/V at 30 kHz

D.C. current

24 μA/A from 1 μA to 1 mA
13 μA/A from 1 mA to 0.1 A
17 μA/A from 0.1 A to 1 A
29 μA/A from 1 A to 10 A
67 μA/A from 10 A to 20 A
220 μA/A at 20 A

A.C. current

From 0.1 mA to 1 mA
150 μA/A at 10 Hz to 30 Hz
110 μA/A at 40 Hz to 1 kHz
560 μA/A at 5 kHz
2200 μA/A at 10 kHz
From 1 mA to 10 mA
140 μA/A at 10 Hz to 30 Hz
95 μA/A at 40 Hz to 1 kHz
150 μA/A at 5 kHz
310 μA/A at 10 kHz
From 10 mA to 100 mA
130 μA/A at 10 Hz to 30 Hz
88 μA/A at 40 Hz to 1 kHz
130 μA/A at 5 kHz
300 μA/A at 10 kHz
From 0.1 A to 1 A
140 μA/A at 10 Hz to 30 Hz
89 μA/A at 40 Hz to 1 kHz
140 μA/A at 5 kHz
410 μA/A at 10 kHz
From 1 A to 10 A
200 μA/A at 10 Hz to 30 Hz
130 μA/A at 40 Hz to 1 kHz
250 μA/A at 5 kHz
300 μA/A at 10 kHz
From 10 A to 20 A
280 μA/A at 10 Hz to 30 Hz
230 μA/A at 40 Hz to 1 kHz
300 μA/A at 5 kHz
390 μA/A at 10 kHz
 At 20 A
310 μA/A at 20 A at 45 Hz to 1 kHz
1000 μA/A at 20 A at 5 kHz

Resistance

15 μΩ/Ω + 20 μΩ up to 1.9 Ω
9 μΩ/Ω from 1.9 Ω to19 Ω
7 μΩ/Ω from 19 Ω to 190 Ω
4 μΩ/Ω from 190 Ω to 19 kΩ
7 μΩ/Ω from 19 kΩ to 190 kΩ
13 μΩ/Ω from 190 kΩ to 1.9 MΩ
24 μΩ/Ω from 1.9 MΩ to 19 MΩ
95 μΩ/Ω from 19 MΩ to 100 MΩ
630 μΩ/Ω from 100 MΩ to 290 MΩ
1.2 mΩ/Ω from 400 MΩ to 640 MΩ
1.8 mΩ/Ω from 640 MΩ to 1100 M Ω

In-situ calibration of electrical measurement and test equipment Ammeters AC current; DC current Direct measurement against a reference standard

D.C. ammeters

From 1 μA to 20 A

A.C. ammeters

From 1 μA to 20 A and at 10 Hz to 10 kHz

Capability

with Calibration and Measurement Capability of -

D.C. ammeters

24 μA/A from 1 μA to 220 μA
13 μA/A from 220 μA to 22 mA
18 μA/A from 22 mA to 220 mA
30 μA/A from 220 mA to 2.2 A
78 μA/A from 2.2 A to 11 A
220 μA/A from 11 A to 20 A

A.C. ammeters

From 1 μA to 220 μA
400 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
400 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz
From 220 μA to 220 mA
300 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
300 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz
From 220 mA to 2.2 A
300 μA/A at 20 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
7100 μA/A from 5 kHz to 10 kHz
From 2.2 A to 11 A
400 μA/A at 40 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
3700 μA/A from 5 kHz to 10 kHz
From 11 A to 20 A
500 μA/A at 45 Hz to 1 kHz
1500 μA/A from 1 kHz to 5 kHz

LCR meters Capacitance; Dissipation factor; Inductance; Resistance Direct measurement against a reference standard

Inductance

From 100 μH to 10 H and at 1 kHz

Capacitance

For 1 pF at 1 kHz and from 1 kHz to 13 MHz

For 10 pF and 100 pF at 1 kHz and from 1 kHz to 13 MHz

For 1 nF at 1 kHz to 13 MHz

From 10 nF from 20 Hz to 100 kHz

For 100 nF from 20 Hz to 100 kHz

For 1μF form 20 Hz to 10 kHz 

Dissipation Factor

For 1 pF from 1.6 kHz to 13 MHz

For 10 pF from 200 Hz to 13 MHz

For 100 pF from 20 Hz to 13 MHz

For 10 nF, 100 nF and 1000 pF at 1 kHz

A.C. resistance

For 0.1 Ω at 1 kHz

For 1Ω from 5 Hz to 1 MHz

For 10 Ω from 5 Hz to 13 MHz

For 100 Ω from 5 Hz to 13 MHz

For 1 kΩ from 5 Hz to 13 MHz

For 10 kΩ from 5 Hz to 1 MHz

For 100 kΩ from 5 Hz to 1 MHz 

 

 

Capability

with Calibration and Measurement Capability of -

Inductance

4.2 mH/H at 100 μH to 300 μH at 1 kHz
3.0 mH/H from 300 μH to 3 mH at 1 kHz
2.2 mH/H from 3 mH to 10 H at 1 kHz
Capacitance


0.7 fF/pF for 1 pF at 1 kHz
4.5 fF/pF for 1 pF from 1 kHz to 1 MHz
15.2 fF/pF for 1 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.4 fF/pF for 10 pF & 100 pF at 1 kHz
0.9 fF/pF for 10 pF & 100 pF from 1 kHz to 1 MHz
2.5 fF/pF for 10 pF & 100 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 1 nF at 1 kHz to 1 MHz
6.3 pF/nF for 1 nF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 10 nF at 20 Hz to 10 kHz
1.9 pF/nF for 10 nF from 10 kHz to 100 kHz
0.5 pF/nF for 100 nF at 20 Hz to 1 kHz
1.3 pF/nF for 100 nF from 1 kHz to 10 kHz
3.5 pF/nF for 100 nF from 10 kHz to 100 kHz
1.0 nF/μF for 1 μF from 20 Hz to 10 kHz
Dissipation Factor
0.0005 for 1 pF at 1.6 kHz to 1 MHz
0.0012 for 1 pF from 1 MHz to 13 MHz
0.0004 for 10 pF at 200 Hz to 1 MHz
0.0011 for 10 pF from 1 MHz to 13 MHz
0.0049 for 100 pF at 20 Hz to 1 kHz
0.0005 for 100 pF from 1 kHz to 1 MHz
0.0013 for 100 pF from 1 MHz to 13 MHz
0.0003 for 10 nF at 1 kHz
0.0004 for 100 nF at 1kHz
0.0005 for 1000 pF at 1kHz
AC Resistance
220 μΩ for 0.1 Ω at 1 kHz
2.9 mΩ for 1 Ω from 5 Hz to 1 MHz
2.2 mΩ for 10 Ω from 1 MHz to 13 MHz
190 mΩ for 100 Ω from 5 Hz to 1 MHz
510 mΩ for 100 Ω from 1 MHz to 13 MHz
2.8 Ω for 1 kΩ from 5 Hz to 1 MHz
4.2 Ω for 1 kΩ from 1 MHz to 13 MHz
28 Ω for 10 kΩ from 5 Hz to 1 MHz
550 Ω for 100 kΩ from 5 Hz to 1 MHz

Ohm meters Resistance Direct measurement against a reference standard

Up to 1 Ω and from 1 Ω to 1 GΩ

Capability

with Calibration and Measurement Capability of -

77 μΩ/Ω + 20 μΩ up to 1 Ω
50 μΩ/Ω from 1 Ω to 1.9 Ω
25 μΩ/Ω from 1.9 Ω to 10 Ω
45 μΩ/Ω from 10 Ω to 19 Ω
21 μΩ/Ω from 19 Ω to 100 Ω
15 μΩ/Ω from 100 Ω to 100 kΩ
19 μΩ/Ω from 100 kΩ to 190 kΩ
24 μΩ/Ω from 190 kΩ to 1 MΩ
120 μΩ/Ω from 1 MΩ to 1.9 MΩ
74 μΩ/Ω from 1.9 MΩ to 10 MΩ
640 μΩ/Ω from 10 MΩ to 19 MΩ
600 μΩ/Ω from 19 MΩ to 100 MΩ
6.1 mΩ/Ω from 100 MΩ to 1 GΩ

Voltmeters AC voltage; DC voltage Direct measurement against a reference standard

D.C. voltmeters

From 1 μV to 1000 V

A.C. voltmeters

From 10 μV to 1000 V and at 10 Hz to 1 MHz

Capability

with Calibration and Measurement Capability of -

D.C. voltmeters

10 μV/V + 0.4 μV from 1 μV to 0.22 V
6 μV/V from 0.22 V to 2.2 V
5 μV/V from 2.2 V to 22 V
8 μV/V from 22 V to 1000 V

A.C. voltmetters

From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz

In-situ calibration of frequency and time standards Signal sources Frequency; Modulation; Sweep; Time interval To be determined

Frequency Characteristics

At 1 Hz to 50 GHz

Output characteristics

From 5 Hz to 50 GHz

Modulation characteristics

AM depth

From 20 Hz to 100 kHz

FM deviation

0.15 MHz to 26.5 GHz

Capability

with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

Modulation characteristics

AM Depth
Carrier 0.15 kHz to 26.5 GHz
10% to 90% Modulation
0.93% from 20 Hz to 400 Hz
0.49% from 400 Hz to 10 kHz
1.71% from 10 kHz to 100k Hz
FM Deviation
0.15 MHz to 26.5 GHz
1.2% Peak deviation 1 to 320 kHz,
Modulation frequencies 10 Hz to 100 kHz
1.2% from 150 kHz to 26.5 GHz
Other aspects as per 1.42

Sweep characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 d

In-situ calibration of frequency, time and waveform measuring equipment Counters; Frequency meters; Time interval meters Frequency; Time interval To be determined

Counters

From 1 Hz to 50 GHz

Time interval

From 10 ns to 105 seconds

Capability

with Calibration and Measurement Capability of-

Counters

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Time interval meters 

1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds.

Frequency standards 

7 parts in 1011 

Frequency analysers; Waveform measuring instruments Current; Distortion; Frequency; Time interval To be determined

Frequency characteristics

At 1 Hz to 50 GHz

Input characteristics

From 10 μV to 1000 V and at 10 Hz to 1 MHz

Timing characteristics

From 10 ns to 105 seconds

Distortion

Measurement of Total Harmonic Distortion (THD),
Input Voltage Range 50 mV to 300 V, Current Range 50 mA to 20 A

Capability

with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 at 1 Hz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Input characteristics

From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz

Timing characteristics

1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds

Distortion

0.007% absolute at < 0.05% at 20 Hz to 20 kHz
13.5% of reading at > 0.05% to < 10% at 20 Hz to 20 kHz
0.027% absolute at < 0.1% at 20 kHz to 50 kHz
26.8% of reading at > 0.1% to < 10% at 20 Hz to 20 kHz
0.05% absolute at < 0.18% at 50 kHz to 100 kHz
26.8% of reading at > 0.18% to < 10% at 50 Hz to 100 kHz

.

Time and frequency metrology - Frequency and time standards Signal sources Frequency; Modulation; Sweep Direct measurement

Capability

including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm

Modulation characteristics

AM Depth
Carrier 0.15 kHz to 26.5 GHz
10% to 90% Modulation
0.93% from 20 Hz to 400 Hz
0.49% from 400 Hz to 10 kHz
1.71% from 10 kHz to 100k Hz
FM Deviation
0.15 MHz to 26.5 GHz
1.2% Peak deviation 1 to 320 kHz,
Modulation frequencies 10 Hz to 100 kHz
1.2% from 150 kHz to 26.5 GHz

Sweep characteristics

5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Output characteristics

From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm

From 1.3 GHz to 18 GHz
 0.13 dB at +20 dBm to -10 dBm
 0.15 dB from -10 dBm to -20 dBm
 0.16 dB from -20 dBm to -30 dBm
 0.19 dB from -30 dBm to -40 dBm
 0.21 dB from -40 dBm to -50 dBm
 0.24 dB from -50 dBm to -60 dBm
 0.26 dB from -60 dBm to -70 dBm
 0.31 dB from -70 dBm to -80 dBm
 0.34 dB from -80 dBm to -90 dBm
 0.42 dB from -90 dBm to -100 dBm
 0.45 dB from -100 dBm to -110 dBm
 0.50 dB from -110 dBm to -120 dBm
 0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
 0.18 dB at +20 dBm to -10 dBm
 0.19 dB from -10 dBm to -20 dBm
 0.21 dB from -20 dBm to -30 dBm
 0.23 dB from -30 dBm to -40 dBm
 0.25 dB from -40 dBm to -50 dBm
 0.27 dB from -50 dBm to -60 dBm
 0.29 dB from -60 dBm to -70 dBm
 0.33 dB from -70 dBm to -80 dBm
 0.36 dB from -80 dBm to -90 dBm
 0.44 dB from -90 dBm to -100 dBm
 0.47 dB from -100 dBm to -110 dBm
 0.51 dB from -110 dBm to -120 dBm
 0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
 0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
 0.67 dB at -10 dBm to -60 dBm
 0.83 dB from -60 dBm to -90 dBm


Time and frequency metrology - Frequency, time and waveform measuring equipment Clocks and timers; Time interval meters Time interval Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
Time interval meters
1 in 109 + 100 ns from 1 μs to 1 000 s
Clocks and watches
0.04 s from 1 min to 24 h
RCD testers, trip time
0.40 ms up to 500 ms
0.75 ms from 500 ms to 2 s

Counters; Frequency meters; Time interval meters Frequency; Time interval Comparison with a reference standard

Capability

including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -

Counters

5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Time interval meters 

1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds.

Frequency standards 

5 parts in 1012 

Frequency analysers; Waveform measuring instruments Distortion; Frequency; Time interval; Voltage Comparison with a reference standard

Capability

including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -

Frequency characteristics

5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz

Input characteristics

From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz

Tming characteristics

1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds

Distortion

0.007% absolute at < 0.05% at 20 Hz to 20 kHz
13.5% of reading at > 0.05% to < 10% at 20 Hz to 20 kHz
0.027% absolute at < 0.1% at 20 kHz to 50 kHz
26.8% of reading at > 0.1% to < 10% at 20 Hz to 20 kHz
0.05% absolute at < 0.18% at 50 kHz to 100 kHz
26.8% of reading at > 0.18% to < 10% at 50 Hz to 100 kHz

.

Stroboscopes; Tachometers Rotational speed Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
Stroboscopes
 0.12 rpm from 6 rpm to 99 rpm
 1.2 rpm from 100 rpm to 999 rpm
 3.0 rpm from 1 000 rpm to 30 000 rpm
Tachometers
 0.02 rpm from 6 rpm to 99 rpm
 0.2 rpm from 100 rpm to 999 rpm
 2 rpm from 1 000 rpm to 99 000 rpm

ISO/IEC 17025 (2005)

Manufactured Goods

Withdrawn
Service Product Determinant Technique Procedure Limitations
Evaluation of electrical appliances and devices - Performance External power supplies, stabilisers and related items Current; Frequency and time interval; Voltage To be determined

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.