National Association of Testing Authorities, Australia
Scope of Accreditation
PLUS ES
Site
Lane Cove Testing Station
Accreditation No.
62
Site No.
15233
Date of Accreditation
14 Jul 1952
Contact
Availability
Services available to external clients
Scope of Accreditation
Withdrawn 01 Jul 2022
Voluntary
ISO/IEC 17025 (2005)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical standards | Current shunts | Current AC-DC difference; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with a Calibration and Measurement Capability of - |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC and low frequency electrical metrology - High-voltage/high-current standards and equipment | High voltage dividers | Current; Current ratio; Voltage; Voltage ratio | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with a Calibration and Measurement Capability of - |
ISO/IEC 17025 (2005)
Infrastructure and Asset Integrity
|
|||||
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of high voltage/power equipment and components - Performance | Clothing materials, gloves and tools for use in high voltage/power applications | Power arc | Not applicable | IEC 61482 | |
Measurement of sound levels in workplaces and the environment | Electrical machinery | Community noise assessments |
by the methods of |
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
|
|||||
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of high voltage/power equipment and components - Energy efficiency classification | Transformers and inductors | Energy labelling and minimum energy performance standards (MEPS) evaluation | Calculations for energy labelling | AS 2374.1.2 | |
Evaluation of high voltage/power equipment and components - Performance | Bushings | AC voltage; DC voltage; Electric strength; Impulse voltage; Power arc | Not applicable |
Electric strength by the methods of AS/NZS 60137; IEC 60137 Direct voltage tests, Alternating voltage tests and Impulse voltage tests |
excluding H.V. wet and RIV tests Direct voltage tests up to 40 kVAlternating voltage tests up to 150 kV at 50 Hz Impulse voltage tests up to 500 kVp Power arc tests up to 70 kV |
Cable feeders; Cables | Heat cycling; Temperature rise; Thermal rating | Not applicable |
AS 1154.1; AS 1154.3 AS 1299AS 1300 AS 1660.1, AS 1660.2.1; AS 1660.2.2; AS 1660.2.3; AS 1660.2.4; AS 1660.3; AS 1660.5.1 AS/NZS 4325.1 |
||
Electrical performance of cables and components | Capacitance; Conductor resistance; High voltage; Impulse voltage withstand; Insulation resistance; Volume resistivity |
Alternating voltage tests by the methods of - IEC 60060-1 Conductor resistance tests by the methods of - AS 1154.1; AS 1154.3 Direct voltage tests by the methods of - IEC 60060-1 Impulse voltage tests by the methods of - IEC 60060-1 Insulation resistance tests by the methods of - AS 1255.2; IEC 60167 Overload performance by the methods of - AS/NZS 4325.1 Short time withstand and peak withstand current tests by the methods of - AS 1154.1; AS 1154.3; AS 1299; AS 1300; AS 1660.1; AS 1660.2.1; AS 1660.2.2; AS 1660.2.3; AS 1660.2.4; AS 1660.3; AS 1660.5.1; AS/NZS 4325.1; IEC 61138; IEC 61230 |
Maximum currents at nominal test voltages: For example 24 kV - 14 kA, 12 kV - 26 kA, 7.2 kV - 36 kA, 1000 V - 50 kA, 690 V - 65 kA, 440 V - 150 kA, 415 V - 150 kA, 230 V - 85 kA. Measurement of capacitance up to 50 mF Measurement of HV power frequency test supply up to 70 kV Impulse voltage tests - Full (1.2/50μ sec) waves, controlled chopped(on the tail) waves by sphere gaps |
||
Clothing materials, gloves and tools for use in high voltage/power applications | Power arc | Not applicable | IEC 61482 | Power arc tests on clothing | |
Insulated systems; Insulation products; Insulators | AC voltage; DC voltage; Impulse voltage; Insulation resistance; Power arc; Power frequency withstand; Surface and volume resistivity | Not applicable |
Insulation resistance tests by the methods of IEC 60167 Direct voltage tests, Alternating voltage tests and Impulse voltage testsby the methods of IEC60060-1 Surface and volume resistivity by the methods of IEC60502-1 Power arc tests by the methods of AS4435.1; IEC 1109 Power frequency withstand tests by the methods of IEC 62475 |
Alternating Voltage tests up to 150 kV at 50 Hz Direct Voltage tests up to 40 kV Impulse Voltage tests peak voltages up to 500 kVpInsulation Resistance tests up to 100 GΩ with measurements at applied voltages up to 5000 V Power frequency withstand testsup to 70 kV |
|
Overhead lines; Three phase cable installations | Sequence impedance | Not applicable |
AS/NZS 61439.6 IEC 61439-6 |
||
Switching control and protective equipment for power systems | Arcing fault due to internal fault; Cut-off current characteristics; Dielectric dissipation; Dimensions; Electrical endurance; Electrical resistance; High voltage withstand; Impulse voltage; Joule integral characteristics; Making and breaking capacities; Overload; Routine load; Short circuit making and breaking capacities; Short time withstand and peak withstand current; Temperature rise; Visual examination | Not applicable |
Circuit breakers and controllers by the methods of - AS 60947.1, AS 60947.2, AS 60947.4; AS 62271.1; AS 62271.100 BS EN and IEC 60947-1, IEC 60947-2, IEC 60947 -4; IEC 62271-1; IEC 62271-100 Switches and isolators by the methods of - AS 1306, AS 2024, AS 2650, AS 3947.3, AS 60265.1, AS 60265.2, AS 62271.1; AS 62271.102, AS 62271.201 IEC 60694, IEC 62271-1, IEC 61439, IEC 62271-1; IEC 62271-102, IEC 62271-105, IEC 62271-201 Switchgear and controlgear assemblies by the methods of - AS 3439.1; AS 61439.1; AS 61439.2; AS 62277.1; AS 62277.200; AS 62277.201; AS 62277.202; AS 62277.203 IEC 60439-1, IEC 60439-2; IEC 61439-1; IEC 61439-2; IEC TR 61641; IEC 62271-1; IEC 62271-200; IEC 62271-201; IEC 62271-202; IEC 62271-203; Fuses and fuse links by the methods of - AS 1033.1, AS 1033.2, AS 60269 BS 60269 IEC 60269, IEC 60282-1, IEC 60282-2 Surge diverters by the methods of - AS 1307.1; AS 1307.2 (pressure relief) IEC 61643-1; IEC 60099-4Cut-off characteristics by the methods of - AS 1033.1; AS 1033.2 IEC 60269; IEC 60282-1; IEC 60282-2 Joule integral characteristics by the methods of - IEC 62475 Temperature rise tests by the methods of - AS 1306; AS 2024; AS 2650; AS 3947.3; AS 60265.1; AS 60265.2; AS 62271.1; AS 62271.100; AS 62271.102; AS 62271.103; AS 62271.104; AS 62271.105; AS 62271.110; AS 62271.111; AS 62271.200; AS 62271.201; AS 62271.202; AS 62271.203; AS/NZS 61439.1; AS/NZS 61439.2 IEC 60265-1; IEC 60265-2; IEC 60694; IEC 62271-1; IEC 62271-100; IEC 62271-102; IEC 62271-103; IEC 62271-104; IEC 62271-105; IEC 62271-110; IEC 62271-111; IEC 62271-200; IEC 62271-201; IEC 62271-202; IEC 62271-203; IEC 60439-1; IEC 60439-2; IEC 61439-1; IEC 61439-2 Mechanical endurance tests by the methods of - AS 3439.1; AS/NZS 61439.1; AS/NZS 61439.2; AS 62271.1; AS 62271.102; AS 62271.103; AS 62271.104; AS 62271.105; AS 62271.110; AS 62271.111 IEC 60439-1; IEC 60439-2; IEC 61439-1, IEC 61439-2; IEC 62271-1; IEC 62271-102; IEC 62271-103; IEC 62271-104; IEC 62271-105; IEC 62271-110; IEC 62271-111 Switch endurance tests by the methods of - AS 62271.1; AS 62271.200; AS 62271.201; AS 62271.202; AS 62271.203 IEC 62271-1; IEC 62271-200; IEC 62271-201; IEC 62271-202; IEC 62271-203 Breaking capacity tests on miniature overcurrent circuit breakers, residual current devices and semi-enclosed fuses by the methods of - AS/NZS 61008.1; AS/NZS 61008.2; AS 61009.1; AS 3190; AS/NZS 60898.1; AS/NZS 60898.2
IEC 61008, IEC 61009, IEC 60898 High power tests by the methods of -IEC 62475 |
Circuit breakers and controllers Tests on low voltage and high voltage circuit breakers, switchgear assemblies, control gear assemblies and busbar trunking systems excluding switching impulse, radio interference voltage, RIV and H.V. wet testsSwitches and isolators Tests on switches, switch-disconnectors, disconnectors, isolators, earthing switches, fuse/switches, fuse/circuits-breakers, switch gear and control gear assemblies, busbar trunking systems, motor starters, contactors excluding switching impulse, RIV and H.V. wet testsFuses and fuse links Tests on low voltage cartridge fuses, semi-enclosed fuses, high voltage expulsion and similar fuses, high voltage current limiting fusesSurge diverters Tests on gap type diverters for high voltage and impulse voltage tests (excluding switching impulse, RIV and H.V. wet tests) and pressure relief testsHigh voltage and low voltage fuse links and current limiting circuit breakers Three phase and single phase tests at various currents and nominal voltages at nominated power factor and TRV capability. For example 24 kV - 14 kA, 12 kV - 26 kA, 7.2 kV - 36 kA, 1000 V - 50 kA, 690 V - 65 kA, 440 V - 150 kA, 415 V - 150 kA, 230 V - 85 kA. Temperature rise tests Three phase and single phase up to 10 000 A ac. test current and 2000 A dc test current |
|
Transformers and inductors | Accuracy tests | Not applicable |
Current transformers and protective current transformers by the methods of - IEC 60044-1 ; IEC 61869-1 BS EN 60044-1:1999 Voltage transformers and protective voltage transformers by the methods of - AS 60044.2, AS 60044.3; AS 60044.5 |
Current transformers and protective current transformers at 50 Hz with test primary currents up to 8 000 A and secondary currents of up to 10 A at unity and 0.8 power factor burdens Voltage transformers and protective voltage transformers at 50 Hz |
|
AC voltage; Impulse voltage; Insulation resistance; Overload; Power frequency withstand; Sequence impedance; Short circuit making and breaking capacities; Temperature rise; Verification of terminal markings; Visual examination | Not applicable |
Combined transformers by the methods of - IEC 60044-3:2002 IEC 61869-1, IEC 61869-4 Current transformers and protective current transformers by the methods of - AS 60044.1 BS EN 60044-1:1999 IEC 61869-1, IEC 60044-1:1996 Neutral earthing transformers by the methods of - AS 1028-1999 IEC 60289:1998 Power transformers and reactors by the methods of - AS 1028-1999, AS 2374.1, AS 2374.2, AS 2374.5 AS 60076.1, AS 60076.11 AS/NZS 60076.3 AS/NZS 60076.6 BS EN 60076-11 IEC 60076-1, IEC 60076-2, IEC 60076-3, IEC 60076-4, IEC 60076-5, IEC 60076-6, IEC 60076-10, IEC 0076-11, IEC 60076-15; IEC 60289:1998 Voltage transformers and protective voltage transformers by the methods of - AS 60044.2, AS 60044.3, AS 60044.5 IEC 60044-2:1997, IEC 60044-5:2004, IEC 60044-7:1999 IEC 61869-1,IEC 61869-2, IEC 61869-3, IEC 61869-5 |
Power transformers, earthing transformers and reactors up to 132 kV at 50 Hz (excluding RIV and H.V wet tests) Current and voltage transformers up to 250 kV at 50 Hz (excluding RIV and H.V wet tests) |
ISO/IEC 17025 (2005)
Manufactured Goods
|
|||||
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electrical equipment approval and safety evaluation | Electrical equipment for explosive environments | Electrical safety | Insulation and electrical protection measurement | Short-circuit tests on electrical equipment for mines - cable coupling devices and restrained plugs and receptacles | |
Electrical machines and auxiliary apparatus | Electrical safety | Fire hazard assessment; Insulation and electrical protection measurement; Visual examination | Glow wire tests |
ISO/IEC 17025 (2017)
Manufactured Goods
|
|||||
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Acoustic performance evaluation of products | Transformers | Sound insulation | Not applicable |
AS/NZS 60076.10, AS 2374.6-1994 IEC 60076-10 |
|
Electrical equipment approval and safety evaluation | Electrical equipment for explosive environments | Degree of protection - IP rating | Not applicable |
AS 60529 IEC 60529 |
up to IP47 for testing - Switching control and protective equipment for power systems Electricity grid and industrial power supply equipment and systems |
Electrical machines and auxiliary apparatus | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS 60470 AS/NZS IEC 60947.4.1, AS/NZS IEC 60947.4.2, AS/NZS IEC 60947.4.3 IEC 60470:1999 |
including glow wire tests | |
Evaluation of fire risk (excluding electrical products) and fire mitigation performance | Fire extinguishers | Electrical non-conductivity | Not applicable | AS 1850 Section 7 Class E (flash over test) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
62
Site No.
15233
Print date
10 Dec 2023