Scope of Accreditation

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure
Electrical equipment approval and safety evaluation Electrical equipment for explosive environments Ignition source risk Optical radiation; Type of protection 'e' increased safety apparatus; Type of protection 'i' intrinsic safety; Type of protection 'm' encapsulated apparatus; Type of protection 'n' non-sparking apparatus; Type of protection 's' special protection; Type of protection 't' dust ignition protection; Type of protection - (EPL) Ga; Type of protection - Fieldbus intrinsically safe concept (FISCO); Type of protection - Intrinsically safe systems

AS2380.1; AS/NZS 60079.0; IEC 60079.0; IEC 61241-0; 

AS/NZS 60079.1:2015
IEC 60079.1 Ed 7.0 (2014)
Ex da Only;

IEC 60079-11; AS/NZS 60079.11; AS 2380.7; AS/NZS 61241.11; IEC 61241-11; 

AS/NZS 60079.25; IEC 60079-25; 

AS/NZS 60079.27; IEC 60079-27;

AS 1826; AS/NZS 1826 (combustible sensor heads only);

AS/NZS 60079.7; IEC 60079-7 (excluding clauses 5.2.7, 6.2.3.1.4, 6.3.3, 6.6.3 and 7.3, vibration test to clause 6.3.4 is limited to an upper limit of 8 kg, measurements under clauses 6.4 and 6.5 are limited to a maximum dynamic current of 10 kA; clauses 6.2 and 6.8 excluding rotating machines rated at more than 400 V and /or 1kW); 

IEC 60079-15; AS/NZS 60079.15 (excluding clause 22.9; clauses 8.10 and 22.13 excluding rotating machines rated at more than 400 V and /or 1kW); 

IEC 60079-18; AS/NZS 60079.18; AS/NZS 61241-18; 

IEC 60079-26; 

AS/NZS 60079.28: 2016
IEC 60079.28 Ed 2.0 (2015) excluding clause 6;

IEC 60079-31;

AS/NZS 62013.1; AS/NZS 62013.2; IEC 62013-1; IEC 60079-2; IEC 60079-35-1; IEC 60079-35-2;

AS/NZS 2229 excluding clause 2.3 and  8.5
Enclosures for electrical equipment Degree of protection - IP rating Not applicable

IEC 60529; AS 60529 (first numeral 4, 5 and 6 plus second numeral 3 and 4 for products whose standards specify the use of the spray nozzle and second numeral 5, 6, 7 and 8); 

Evaluation of fire risk (excluding electrical products) and fire mitigation performance Belting Flame propagation; Ignitability Not applicable

AS 1334.10; 

for compliance with-

MDG 3608 clauses 3.2.2.3, 3.2.4.1; 3.3.1.1, 3.4.4.3, 7.2.1.1; 

AS 4606:2012 clauses 6.1.4, 6.2.2, 6.3.1, 6.3.2

Material performance evaluation of elastomers, plastics and composite products Belting Electrical resistance Not applicable

AS 1334.9; 

for compliance with-

MDG3608 clauses 3.2.2.5, 3.2.4.3, 3.3.1.3; 

AS 4606:2012 clauses 6.1.6, 6.2.4.1, 6.3.1, 6.3.2 

Performance evaluation of personnel protection equipment and general ballistic measurements Flammable gas monitors Performance tests Accuracy testing; Climate; Durability; Functionality

AS/NZS 60079.29.1; IEC 60079-29-1 excluding clause 5.4.21 other than IEC 61000-4-4;

AS/NZS 60079.29.1 (2008); IEC 60079-29-1 (2016) excluding clause 5.4.25

Registration of design of plant used to determine or monitor the presence of gas order 2015 sections 6 & 7
Oxygen monitors; Toxic gas monitors Performance tests Accuracy testing; Climate; Durability; Functionality

 AS 4641 excluding clauses 4.23 and 5.23;

AS/NZS 4641:2007 excluding clauses 3.25 and 4.25

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.