SLR Consulting Australia Pty Ltd

Site

Perth Stack Laboratory

Accreditation No.

3130

Site No.

15027

Date of Accreditation

Address

Unit 5/31 Century Road
Malaga, WA 6090
Australia

slrconsulting.com

Contact

Miss Sandra Lonergan P: +61 (08) 94225900

Availability

Services available to external clients

Scope of Accreditation

Withdrawn

Perth Stack Laboratory

ISO/IEC 17025 (2005)

Environment

Withdrawn
Service Product Determinant Technique Procedure
Analysis for physical and chemical characteristics Air - Ambient Carbon monoxide Direct reading instrument

AS 3580.7.1

Particulate matter - PM10 Tapered element oscillating microbalance (TEOM)

AS 3580.9.8

Suspended particulate matter - PM2.5continuous direct mass Tapered element oscillating microbalance (TEOM)

AS 3580.9.13

Sulfur dioxide Direct reading instrument

AS 3580.4.1

Suspended particulate matter - PM2.5 Beta attenuation monitors

AS 3580.9.12

Nitrogen - Oxidised Direct reading instrument

AS 3580.5.1

Suspended particulate matter - PM10 Beta attenuation monitors

AS 3580.9.11

Emissions - Industrial Particulate matter - PM10 Classical

USEPA 201A

Sulfur dioxide Autoanalyser (AA)

USEPA 6C

Carbon monoxide Gas analyser

USEPA 10

Particulate matter

USEPA 5

Moisture Classical

USEPA 4

Sulfur dioxide Classical

USEPA 6

Emissions - Industrial; Emissions - Stack Flow rate; Velocity Classical

USEPA 2

Sulfur dioxide Autoanalyser (AA)

USEPA 6C

Carbon monoxide; Nitrogen - Oxidised; Oxygen Electrochemical gas analyser

USEPA CTM-034, ASTM D6522-00

Particulate matter Classical

USEPA 17

Nitrogen - Oxidised; Nitrogen dioxide Gas analyser

USEPA 7E

Carbon dioxide (CO2); Nitrogen - Oxidised; Oxygen; Sulfur dioxide Gas analyser

USEPA 20

Carbon dioxide (CO2); Oxygen Classical

USEPA 3A

Sample collection Air - Ambient; Emissions - Industrial Not applicable

AS 3580.9.3 - Total suspended particulates (TSP)
AS 3580.9.6 - PM10 
AS 3580.9.9 - Particulates - PM10(suspended) low volume sampler (LVAS) by gravimetric
AS 3580.9.10 - Particulates - PM2.5 (suspended) low volume sampler (LVAS) by gravimetric
AS 3580.9.14 - Particulates - PM2.5 (suspended) high volume sampler with size selective inlet (HVAS) by gravimetric
AS 3580.10.1 - Particulate matter - deposited matter
AS 3580.10.2 - Impinged matter by gravimetric
AS 4323.1 - selection of sampling positions for stationary sources
AS 4323.2 - Total particulate matter (Isokinetic)
AS 4323.3 - Odour
AS 4323.4 - Area source sampling (flux chamber)
California EPA Air Resource Board (Carb) 429 - Polycyclic aromatic hydrocarbons
USEPA method 1 - sample and velocity traverse for stationary sources
USEPA method 1A - sample and velocity traverse for stationary sources with
small stacks or ducts
USEPA method 2 - flow rate and velocity by classical
USEPA method 2C - Determination of gas velocity and volumetric flow rate in small stacks or ducts (standard pitot tube)
USEPA method 3 - Dry gas density
USEPA method 3A - oxygen and carbon monoxide concentrations in emissions
from stationary sources
USEPA method 4 - moisture content
USEPA method 5 - particulate matter emissions from stationary sources
USEPA method 6 - sulfur dioxide emissions from stationary sources by impinger
USEPA method 6C - sulfur dioxide emissions from stationary sources (instrument)
USEPA Method 7A - nitrogen oxide emissions from stationary sources
USEPA Method 7C - nitrogen Oxide emissions from stationary sources
USEPA method 7E - oxides of nitrogen from stationary sources (instrumental analyser)
USEPA method 8 - Sulfuric acid mist and sulfur trioxide
USEPA method 10 - carbon monoxide emissions from stationary sources
USEPA method 11 - Hydrogen sulfide
USEPA method 12 - Lead
USEPA method 13B - Fluorides
USEPA method 17 - particulate emissions from stationary sources (in-stack filtration method)
USEPA method 18 - gaseous organic compound emissions by GC
USEPA method 20 - nitrogen oxides, sulfur dioxide and diluent emissions from stationary gas turbines
USEPA 23 - Dioxins and furans
USEPA method 25A and method 25B - Volatile organic compounds
USEPA method 26 - hydrogen chloride emissions from stationary sources
USEPA method 26A - Hydrogen halide; halogens by isokinetic
USEPA method 29 - Metals
USEPA method 201A - Particulate matter - PM2.5 , PM10
USEPA method SW 846 M0030 - volatile organic sampling train (VOST)
USEPA method SW 846 M0031 - volatile organic compounds (large tube)
USEPA method SW 846 M0040 - principal organic hazardous constituents from tedlar bags
USEPA method 201A - PM10 in stationary sources
USEPA Method TO-17 - volatile organic compounds in ambient air using active sampling onto sorbent tubes
ISO 10780 Velocity and volumetric flow rate
CARB 425 - total chromium and hexavalent chromium
USEPA CTM-034 and ASTM D6522-00 - carbon monoxide, oxygen and nitrogen oxide emissions from stationary industrial processes
USEPA CTM-036 - measurement of isocyanate compounds in stack emissions
Stack-Air H2S:1 - hydrogen sulfide in stack emissions
SA EPA 03.01 - Sulfuric acid mist and sulfur trioxide
SA EPA 03.03 - Fluorine by impinger
SA EPA 03.04 - Chlorine by impinger
SA EPA 03.05 - Hydrogen sulfide
SA EPA 03.07 - Metals

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.