Port Macquarie Hastings Council

Site

Port Macquarie Hastings Environmental Laboratory

Accreditation No.

15581

Site No.

17096

Date of Accreditation

21 Apr 2009

Address

7 Major Innes Road
Port Macquarie , NSW 2444
Australia

hastings.nsw.gov.au

Contact

Dr Maree Smith P: +61 (02) 65818810

Availability

Services available to external clients

Scope of Accreditation

Port Macquarie Hastings Environmental Laboratory

ISO/IEC 17025 (2017)

Environment

Service Product Determinant Technique Procedure
Analysis for nutrients Bore waters; Industrial waters - Treated; Sewage; Steam-raising waters; Surface waters; Trade wastes; Treated effluent Nitrogen - Nitrite; Nitrogen - Oxidised Flow injection analyser (FIA)

APHA 4500-NO3-I (in-house method MET053)

Nitrogen - Total Flow injection analyser (FIA)

APHA 4500 N-C (in-house method MET035)

Nitrogen - Nitrate Calculation

APHA 4500-NO3-I (in-house method MET053)

Nitrogen - Organic; Nitrogen - Total Kjeldahl (TKN) Calculation

APHA 4500-Norg-B (in-house method MET035)

Phosphorus - Total Flow injection analyser (FIA)

APHA 4500 P-J (in-house method MET035)

Phosphorus - Ortho; Phosphorus - Soluble reactive Flow injection analyser (FIA)

APHA 4500 P-G (in-house method MET053)

Nitrogen - Ammonia Flow injection analyser (FIA)

APHA 4500-NH3-H (in-house  method MET053)

Analysis for physical and chemical characteristics Ground waters; Industrial waters - Treated; Saline waters; Sewage; Steam-raising waters; Surface waters; Trade wastes; Treated effluent pH Electrometric

APHA 4500-H+ (in-house method MET014)

Chlorophyll a UV-vis spectrophotometry

APHA 10200-H (in-house method  MET008)

Conductivity Electrometric

APHA 2510 (in-house method MET009)

Solids - Suspended; Solids - Total Gravimetric

APHA 2540-D (in-house method MET017)

Biochemical oxygen demand (BOD) Dissolved oxygen (DO) analyser

APHA 5210B, 4500-O-G (in-house method  MET005)

Ground waters; Industrial waters - Treated; Steam-raising waters; Surface waters; Trade wastes; Treated effluent Fluoride Ion selective electrode (ISE)

in-house method  MET049

Ground waters; Saline waters; Sewage; Surface waters; Trade wastes; Treated effluent Turbidity Nephelometry

APHA 2130 (in-house method MET018)

Colour - Apparent; Colour - True UV-vis spectrophotometry

APHA 2120-C (in-house method MET036)

Ground waters; Sewage; Surface waters; Trade wastes; Treated effluent Alkalinity Titration

APHA 2320 (in-house method MET042)

ISO/IEC 17025 (2017)

Food and Beverage

Service Product Determinant Technique Procedure
Analysis of physical and nutritional characteristics Waters for potable and domestic purposes Biochemical oxygen demand (BOD) Dissolved oxygen (DO) analyser

APHA 5210B, 4500-O-G (in-house method MET005)

Solids - Suspended; Solids - Total Gravimetric

APHA 2540-D (in-house method MET017)

Colour - Apparent UV-vis spectrophotometry

APHA 2120-C (in-house method MET036)

Alkalinity Titration

APHA 2320 (in-house method MET042)

Nitrogen - Nitrate Calculation

APHA 4500-NO3-I (in-house method MET053)

Chlorophyll a UV-vis spectrophotometry

APHA 10200-H (in-house method MET008)

pH Electrometric

APHA 4500-H+ (in-house method MET014)

Turbidity Nephelometry

APHA 2130 (in-house method MET018)

Phosphorus - Total Flow injection analyser (FIA)

APHA 4500 P-J (in-house method MET035)

Nitrogen - Total Kjeldahl (TKN) Calculation

APHA 4500-Norg-B (in-house method MET035)

Nitrogen - Total Flow injection analyser (FIA)

APHA 4500 N-C (in-house method MET035)

Fluoride Ion selective electrode (ISE)

in-house method  MET049

Conductivity Electrometric

APHA 2510 (in-house method MET009)

Phosphorus - Ortho; Phosphorus - Soluble reactive Flow injection analyser (FIA)

APHA 4500 P-G (in-house method MET053)

Nitrogen - Nitrite Flow injection analyser (FIA)

APHA 4500-NO3-I (in-house method MET053)

Nitrogen - Ammonia Flow injection analyser (FIA)

APHA 4500-NH3-H (in-house method MET053)

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.