ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators AC voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.05% reading + 20 μV from 0.01 V to 0.25 V at 50 Hz to 20 kHz
0.08% reading + 30 μV from 0.01 V to 0.25 V at 20 kHz to 50 kHz
0.1% reading + 30 μV from 0.01 t V to 0.25 V at 50 kHz to 100 kHz
0.02% reading from 0.25 V to 300 V at 50 Hz to 20 kHz
0.02% reading above 300 V to 1 000 V at 50 Hz to 200 Hz
0.04% reading above 300 V to 1 000 V at 200 Hz to 20 kHz
0.04% reading above 0.25 V to 300 V at 20 kHz to 50 kHz
0.08% reading above 300 V to 1 000 V at 20 kHz to 50 kHz
0.2% reading above 0.25 V to 10 V at 10 Hz
0.08% reading above 0.25 V to 1 000 V at 20 Hz to 50 Hz
0.08% reading above 0.25 V to 50 V at 50 kHz to 100 kHz
0.2% reading above 50 V to 300 V at 50 kHz to 100 kHz
0.4% reading above 300 V to 1 000 V at 50 kHz to 100 kHz
0.2% reading above 0.25 V to 50 V at 100 kHz to 1 MHz
0.1% reading from 2.5 mA to 20 A at 50 Hz to 1 kHz
Resistance Comparison with a reference standard

0 Ω to 100 MΩ

Capability

with a Calibration and Measurement Capability of -
27 μΩ at 0 Ω
0.01% reading + 10 μΩ from 1 mΩ to 1 MΩ
0.1% reading from 1 MΩ to 100 MΩ
DC voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.7 μV at 0 V
10 μV/V or 1.5 μV whichever is the greater in the range 1 mV to 1.1 kV

AC current Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.1% reading from 2.5 mA to 20 A at 50 Hz to 1 kHz

DC current Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
1.3 nA at 0 A
0.02% reading + 0.02 μA up to 2 A
0.02% reading from 2 to 20 A
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Current clamps DC current Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
1.3 nA at 0 A
0.02% reading + 0.02 μA up to 2 A
0.02% reading from 2 to 20 A
1% reading from 20 A  to 1 000 A for clamp-on ammeters using multiple turns
AC current Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.1% reading above from 2.5 mA to 20 A at 50 Hz to 1 kHz
1.0% reading from 20 A to 900 A at 50 Hz for clamp-on ammeters using multiple turns

Ohm meters Resistance Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
27 μΩ at 0 Ω
0.01% reading + 10 μΩ from 1 mΩ to 1 MΩ
0.1% reading from 1 MΩ to 100 MΩ
Voltmeters DC voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.7 μV at 0 V
10 μV/V or 1.5 μV whichever is the greater in the range 1 mV to 1.1 kV

AC voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.05% reading + 20 μV from 0.01 V to 0.25 V at 50 Hz to 20 kHz
0.08% reading + 30 μV from 0.01 V to 0.25 V at 20 kHz to 50 kHz
0.1% reading + 30 μV from 0.01 t V to 0.25 V at 50 kHz to 100 kHz
0.02% reading from 0.25 V to 300 V at 50 Hz to 20 kHz
0.02% reading above 300 V to 1 000 V at 50 Hz to 200 Hz
0.04% reading above 300 V to 1 000 V at 200 Hz to 20 kHz
0.04% reading above 0.25 V to 300 V at 20 kHz to 50 kHz
0.08% reading above 300 V to 1 000 V at 20 kHz to 50 kHz
0.2% reading above 0.25 V to 10 V at 10 Hz
0.08% reading above 0.25 V to 1 000 V at 20 Hz to 50 Hz
0.08% reading above 0.25 V to 50 V at 50 kHz to 100 kHz
0.2% reading above 50 V to 300 V at 50 kHz to 100 kHz
0.4% reading above 300 V to 1 000 V at 50 kHz to 100 kHz
0.2% reading above 0.25 V to 50 V at 100 kHz to 1 MHz
0.1% reading from 2.5 mA to 20 A at 50 Hz to 1 kHz
DC and low frequency electrical metrology - Electrical standards AC/DC transfer instruments Current; Voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.02% reading from 0.25 V to 300 V at 50 Hz to 20 kHz
0.02% reading above 300 V to 1 000 V at 50 Hz to 200 Hz
0.04% reading above 300 V to 1 000 V at 200 Hz to 20 kHz
0.04% reading above 0.25 V to 300 V at 20 kHz to 50 kHz
0.08% reading above 300 V to 1 000 V at 20 kHz to 50 kHz
0.2% reading above 0.25 V to 10 V at 10 Hz
0.08% reading above 0.25 V to 1 000 V at 20 Hz to 50 Hz
0.08% reading above 0.25 V to 50 V at 50 kHz to 100 kHz
0.2% reading above 50 V to 300 V at 50 kHz to 100 kHz
0.4% reading above 300 V to 1 000 V at 50 kHz to 100 kHz
0.2% reading above 0.25 V to 50 V at 100 kHz to 1 MHz
0.1% reading from 2.5 mA to 20 A at 50 Hz to 1 kHz
Conductance boxes; Precision resistors; Resistance boxes Resistance Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
0.01% reading + 10 μΩ from 1 mΩ to 1 MΩ
0.1% reading from 1 MΩ to 100 MΩ
Voltage standards - E.M.F. reference devices Voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
5 μV/V at 1 V to 10 V

Voltage standards - Standard cells Voltage Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
5 μV at 1 V, 1.018 V and 10 V

Temperature metrology - Ancillary temperature measuring equipment Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators Volt to temperature conversion Direct measurement by electrical input

Capability

Including portable temperature measuring instruments by electrical simulation
with Calibration and Measurement Capability of -
Type K Thermocouples
0.10 °C from -200 °C to 0 °C
0.04 °C above 0 °C to 1000 °C
0.05 °C above  1000 °C to 1372 °C
Type T Thermocouples
0.07 °C from -200 °C to 0 °C
0.04 °C above  0 °C to 400 °C
Type B Thermocouples
0.12 °C from 800 °C to 1820 °C
Type E Thermocouples
0.07 °C from -200 °C to 0 °C
0.04 °C above  0 °C to 1000 °C
Type J Thermocouples
0.08 °C from -200 °C to 0 °C
0.04°C from 0°C to 1200°C
Type N Thermocouples
0.07 °C from -100 °C to 0 °C
0.06 °C above  0 °C to 800 °C
0.04 °C above  800 °C to 1300 °C
Type R Thermocouples
0.10 °C from 400 °C to 1768 °C
Type S Thermocouples
0.11 °C from 300 °C to 1768 °C
Cold Junction
0.13 °C at 0 °C
0.11 °C at 21 °C
Resistance to temperature conversion Direct measurement by electrical input

Capability

Including portable temperature measuring instruments by electrical simulation
with Calibration and Measurement Capability of -
RDT Indicators
0.008 °C from -200 °C to 800 °C
Time and frequency metrology - Frequency, time and waveform measuring equipment Counters Time interval Comparison with a reference standard

Capability

with a Calibration and Measurement Capability of -
3 parts in 109 time base only

Frequency analysers Time interval Measurement against reference standard

Capability

with a Calibration and Measurement Capability of -
3 parts in 10for time base measurements

Frequency meters Current; Voltage Measurement against reference standard

Capability

Amplitude Measurements
with a Calibration and Measurement Capability of -
D.C.voltage
 0.7 μV at 0 V
 10 μV/V or 1.5 μV whichever is the greater in the range 1 mV to 1.1 kV
 A.C. voltage
 0.05% reading + 20 μV from 0.01 V to 0.25 V at 50 Hz to 20 kHz
 0.08% reading + 30 μV from 0.01 V to 0.25 V at 20 kHz to 50 kHz
 0.1% reading + 30 μV from 0.01 t V to 0.25 V at 50 kHz to 100 kHz
 0.02% reading from 0.25 V to 300 V at 50 Hz to 20 kHz
 0.02% reading above 300 V to 1 000 V at 50 Hz to 200 Hz
 0.04% reading above 300 V to 1 000 V at 200 Hz to 20 kHz
 0.04% reading above 0.25 V to 300 V at 20 kHz to 50 kHz
 0.08% reading above 300 V to 1 000 V at 20 kHz to 50 kHz
 0.2% reading above 0.25 V to 10 V at 10 Hz
 0.08% reading above 0.25 V to 1 000 V at 20 Hz to 50 Hz
 0.08% reading above 0.25 V to 50 V at 50 kHz to 100 kHz
 0.2% reading above 50 V to 300 V at 50 kHz to 100 kHz
 0.4% reading above 300 V to 1 000 V at 50 kHz to 100 kHz
 0.2% reading above 0.25 V to 50 V at 100 kHz to 1 MHz
 0.1% reading from 2.5 mA to 20 A at 50 Hz to 1 kHz

Stroboscopes Time interval Measurement against reference standard

Capability

with a Calibration and Measurement Capability of -
0.1% reading from 2 pulses per sec to 1000 pulses per sec

Tachometers Rotational speed Measurement against reference standard

Capability

with a Calibration and Measurement Capability of -
0.1% reading for
Hand held tachometers from 100 r/min to 15000 r/min
Optically coupled tachometers from  1000 r/min to 60,000 r/min

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.