Qenos Pty Ltd

Site

Qenos Technical Centre

Accreditation No.

2649

Site No.

2642

Date of Accreditation

20 Jun 1989

Address

Gate 13/ 611 Kororoit Creek Road
Altona, VIC 3018
Australia

qenos.com

Contact

Mr Kim Fairhall P: +61 (03) 99313811

Availability

Services conditionally available to external clients

Scope of Accreditation

Qenos Technical Centre

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Material performance evaluation of elastomers, plastics and composite products Moulding and extrusion plastics Tensile properties Not applicable

In-house method - LTMM 2.1.3 and  ASTM D638

0.1 N to 10 kN

Specific gravity Not applicable

In-house method - LTMM 2.3.3; ASTM D1505 and ASTM D2839

Gradient tube method
Melt-mass flow rate (MFR) Not applicable

In-house method - LTMM 2.4.1; ISO 1133.1 Procedure A; ISO 1133.1 Procedure B and ASTM D1238 Procedure A 

Including Melt Flow Index
Oxidation induction time (OIT) Differential scanning calorimetry (DSC) ISO 11357-6 and In-house method -LTMM 2.3.1

Stress crack resistance; Tensile properties Not applicable

In-house method - LTMM 2.1.6 and ASTM D638;

AS 1049; ASTM D1693 and In-house method - LTMM 2.3.7

Secant modulus of elasticity;
Environmental stress crack resistance
Accelerated ageing; Accelerated weathering; Thermal analysis Not applicable

In-house method - LTMM 2.7.4, ISO 4892.1, ISO 4892.2; ASTM D2565, ASTM G151 and ASTM G155

Including Thermal stability
Bending properties Not applicable

In-house method - LTMM 2.1.4 and ASTM D790 Procedure B

Including Flexural modulus of elasticity
Pipe material and related products Hydrostatic pressure Classical

AS/NZS 1462.6

In-house method - LTMM 2.1.16

ISO 13479
ISO 9080
ISO 1167-1, ISO 1167-2, ISO 1167-3, ISO 1167-4

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.