Queensland University of Technology - School of Chemistry, Physics and Mechanical Engineering

Site

QUT Photometric Laboratory – Performance & Approval Testing – School of Chemistry, Physics and Mechanical Engineering – Gardens Point Campus

Accreditation No.

4819

Site No.

22882

Date of Accreditation

Address

M Block, Level 2, 2 George Street
Brisbane City, QLD 4000
Australia

lighting.qut.edu.au

Contact

Mr Ian Rolfe Cowling P: +61 0421334393

Availability

Services available to external clients

Scope of Accreditation

Withdrawn

QUT Photometric Laboratory – Performance & Approval Testing – School of Chemistry, Physics and Mechanical Engineering – Gardens Point Campus

ISO/IEC 17025 (2005)

Manufactured Goods

Withdrawn
Service Product Determinant Technique Procedure Limitations
Evaluation of consumer and industrial lighting, optical systems and eyewear Advertising and information display lighting LuminanceField measurement of luminance Direct measurement using a reference meter AS 1428, AS 1680, ASTM E2073-10, DIN 67510-01 Field measurements in the range from 0 cd/m-2 to 5000 cd/m-2
Automotive lightsIlluminated registration plates; Reversing lamps, turn signal lamps, side and position markers and outline lamps, fog lamps, headlamps, stop lamps (including high mounted) and tail lamps, including Chromaticity; Distribution of luminous intensity; Endurance; Illuminance; Luminance Direct comparison against a reference meter; Direct comparison against a reference standard; Direct measurement by goniophotometer; Direct measurement using a reference colorimeter; Direct measurement using a reference meter; Direct measurement using a reference spectrophotometer; Direct measurement using a reference standard ADR 48/00, 53/00;
ADR 1/00, 6/00, 45/01, 46/00, 49/00, 50/00, 52/00, 53/00, 54/00, 55/00, 60/00,
74/00, 75/00, 76/00, 77/00,  other standards listed under these ADRs, JIS D5500;

Calculation of chromaticity coordinates ofincandescent lamps, LED
and other light sources from spectral irradiance data;

Measurement of luminance of illuminated registration plates in the range from 1 mcd m-2 to 1500 cd m-2;
ADR 75/00 Intensity measurements only before and after soiling or lifetime testing;
Aviation signallingObstacle lighting Distribution of luminous intensity; Illuminance; Power AC and DC Direct measurement by goniophotometer; Direct measurement using a reference meter CASA Manual of Standards Part 139 Obstacle Lighting
Emergency evacuation lighting and exit luminaires; LED and other solid state lighting sources Chromaticity; Classification of emergency luminaires; Distribution of luminous intensity; Illuminance; Power AC and DC Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference colorimeter; Direct measurement using a reference meter; Direct measurement using a reference spectrophotometer; Direct measurement using a reference standardTo be determined AS 2293 and AS/NZS 2293 Emergency evacuation and escape lighting and exit signs
General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sources Chromaticity; Correlated colour temperature; Illuminance; Luminous flux; Power AC and DC Direct measurement by goniophotometer; Direct measurement by integrating sphere; Direct measurement using a reference colorimeter; Direct measurement using a reference meter; Direct measurement using a reference spectrophotometer

Chromaticity - measurement of CIE 1931 coordinates (x, y) for incandescent and non-incandescent lamps
 from 2000 to 8000 K;

Chromaticity - calculation from spectral irradiance data - CIE 15.2;
Correlated Colour Temperature - calculation from spectral irradiance data - CIE 15.2, CIE S025, IES LM-79;
Illuminance - AS 1158, AS 1680, CIE 121, CIE  24; 

Luminous flux - AS/NZS 1158, AS 1680, AS/NZS 1680, AS/NZS 4782, AS/NZS 4847, AS/NZS 4934, CIE 24, CIE 84, CIE 121,  IES LM-35, IES LM-41, IES LM-79, IES LM-84;

Power -  AS/NZS 1158, AS 1680, AS/NZS 1680, AS/NZS 2080, AS 2144, AS 2293, AS/NZS 2293, AS/NZS 4192, AS/NZS 4782, AS/NZS 4847, AS/NZS 4934, Australian Design Rules, CASA MOS Part 139, CIE 15.2, CIE 24, CIE 84, CIE 121, IES LM-35, IES LM-41, IES LM-79, IES LM-84;

Spectral irradiance - IES LM 79-08;

Chromaticity - measurement of CIE 1931 coordinates (x, y) in the range 2000 to 8000 K;

Correlated colour temperature in the range 2000 to 6000 K ;

Illuminance from lamps approximating Source A conditions in the range 0.1 - 5000 lux;

Luminous flux - incandescent flux lamp for lamps of approximately 2856 K from 700 - 2000 lm;

Luminous flux - non-incandescent lamps from 50 - 25 000 lm ;
Spectral irradiance  - in the range 380 nm to 780nm;
Distribution of luminous intensity; Illuminance; Power AC and DCMeasurement of illuminance in the laboratory and in the field Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference meter; Direct measurement using a reference standard AS 1680, AS/NZS 1680, CIE 121, IES LM79 Luminaires for interior lighting, including LED-based lamps;
with maximum light emitting dimensions not exceeding 1.25 m;
Measurement of illuminance in the laboratory and in the field
High intensity discharge lamps Distribution of luminous intensity; Illuminance; Power AC and DC Direct measurement by goniophotometer; Direct measurement using a reference meter CIE 24:1973; IES LM 41; Luminaires for flood lighting, including LED-based lamps;
with maximum light emitting dimensions not exceeding 1.25 m

Lighting for roads and public spaces Distribution of luminous intensity; Illuminance; Power AC and DCMeasurement of illuminance in the laboratory and in the field Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference device; Direct measurement using a reference standard AS/NZS 1158 Lighting for roads and public places;
CIE 15 Lighting of Roads for Motor and Pedestrian Traffic, and
Roadway Lighting ANSI/IES RP-8-14
Luminaires for road lighting, including LED-based lamps with maximum light emitting dimensions not exceeding 1.00 m;
Measurement of illuminance from lamps approximating Source A conditions in the range 0.1 - 5000 lux;
Measurement of illuminance in the laboratory and in the field
Luminance Direct measurement using a reference meter; Direct measurement using a reference standard AS/NZS 1158 Lighting for roads and public places;
CIE 115 Lighting of Roads for Motor and Pedestrian Traffic, and 
Roadway Lighting ANSI/IES RP-8-14
Measurement in the range from 1 mcd m-2 to1500 cd m-2
Parallel plate samples and filters Spectral transmittance Direct measurement using a reference meter; Indirect measurement using a spectrophotometer and software integration in-house procedure 3.52.01 Spectrophotometry - Spectral Transmittance  Measurements of spectral transmission of filters
with total broadband visible transmission above 10%
In the range from 380 nm to 780 nm
Tactile ground surface indicators (TGSI)Tactile ground surface indicators (TGSI) Luminance contrastLuminous contrast Direct measurement using a reference meter AS/NZS 1428.4.1  in the range from 1 mcd m-2 to 1500 cd m-2
Traffic signalling and warning signs Chromaticity; Distribution of luminous intensity; Illuminance; Luminance; Power AC and DC Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference colorimeter; Direct measurement using a reference meter; Direct measurement using a reference spectrophotometer; Direct measurement using a reference standard AS/NZS 2144; Appendix D Traffic signal lanterns;
AS/NZS 2144, AS/NZS 4192 Illuminating Flashing Arrow Signs,

Windows, windscreens and other safety glazing products Luminous transmittance Direct measurement using a reference meter; Indirect measurement using a spectrophotometer and software integration ADR 8/01, AS 2080
Material performance evaluation of paint and related products Architectural coatings; Automotive coatings; Decorative coatings; Industrial coatings; Marine coatings; Road marking paintPhotoluminescent materials Surface luminance Measurement using a reference meter AS 1428
ASTM E2073-10;
DIN 67510-01
Laboratory measurements in the range from 1 mcd/m-2 to 1500 cd/m-2
Field measurements in the range from 0 cd/m-2 to 5000 cd/m-2

ISO/IEC 17025 (2017)

Manufactured Goods

Withdrawn
Service Product Determinant Technique Procedure Limitations
Evaluation of consumer and industrial lighting, optical systems and eyewear LED and other solid state lighting sources Median lifetime testing Calculation AS/NZS 4934.1 Incandescent lamps
Evaluation of electrical appliances and devices - Energy efficiency classification Lamps Energy labelling and minimum energy performance standards (MEPS) evaluation Calculations for energy labelling; Evaluation of test results against stated performance criteria; Visual assessment of marking and other attributes against stated criteria

AS 4934.2 Minimum Energy Performance Standards (MEPS)

Greenhouse and Energy Minimum Standards Act 2012, 

Greenhouse and Energy Minimum Standards (Incandescent Lamps for General Lighting Services) Determination 2015, 

Greenhouse and Energy Minimum Standards (Incandescent Lamps for General Lighting Services) Determination 2016

Incandescent lamps only

ISO/IEC 17025 (2005)

Materials

Withdrawn
Service Product Determinant Technique Procedure Limitations
Material performance evaluation of refractories, ceramics and related materials CeramicsPhotoluminescent materials Surface luminance Measurement using a reference meter AS 1428;
ASTM E2073-10;
DIN 67510-01

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.