APR Laboratory Pty Ltd

Site

Australian Photometry and Radiometry Laboratory

Accreditation No.

15508

Site No.

22937

Date of Accreditation

25 Jun 2007

Address

Factory 2, 21-29 Railway Avenue
Huntingdale, VIC 3166
Australia

aprlab.com.au

Contact

Mr Anthony (Tony) Bergen P: +61 (03) 95681879

Availability

Services available to external clients

Scope of Accreditation

Australian Photometry and Radiometry Laboratory

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Evaluation of consumer and industrial lighting, optical systems and eyewear Advertising and information display lighting; Aviation signalling; General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sources; Lighting for roads and public spaces; Monitors; Sky and sunlight; Traffic signalling and warning signs; Transient light sources including warning lights, beacons and variable message signs Luminance Not applicable

SJ&A 3.1.4;

Field measurement of luminance in the range 0 to 150 000 cd/m2;

Automotive lights; Aviation signalling; General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; High intensity discharge lamps; LED and other solid state lighting sources; Lighting for roads and public spaces; Maritime signalling; Railway signalling; Surgical and diagnostic lighting; Traffic signalling and warning signs Chromaticity Not applicable

SJ&A 4.2;

SJ&A 10.2;

IES LM-79;

Automotive lights; Aviation signalling; General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; High intensity discharge lamps; LED and other solid state lighting sources; Lighting for roads and public spaces; Maritime signalling; Railway signalling; Surgical and diagnostic lighting; Traffic signalling and warning signs; UVA lamps and UVC lamps Current; Power; Power AC and DC; Power factor; Voltage Not applicable

SJ&A 9; IES LM-79;

Automotive lights; LED and other solid state lighting sourcesincluding stop lamps; tail lamps; reversing lamps; indicator lamps; side and position markers; outline markers headlamps, motorcycle headlamps and gas discharge headlamps Chromaticity; Distribution of luminous intensity Not applicable

ADR 1/00, 6/00, 45/01, 46/00, 48/00, 49/00, 50/00, 52/00, 53/00, 54/00, 55/00, 60/00,
 74/00, 75/00, 76/00, 77/00, and standards stated to be equivalent within these ADRs;

Aviation signalling Chromaticity; Distribution of luminous intensity Not applicable

ICAO Annex 14 Aerodromes Vol 1 - Design andOperations, 2013;
Section 5 (signals), Section 6 (obstacle lights), Appendix 1 and Appendix 2;
CASA Manual of Standards Part 139 - Aerodromes Chapter 9; Division 1 Sections 9.14 and 9.15, Division 4, Division 9, Division 10, Division 10 Section 1.75, Division 11, Division 11 Section 9.111.
Photometric and colorimetric requirements of Section 8.6.6 (movement area guidance signs);
SJ&A 7.6;

Eye protectors, filters and related eyewear for industrial applications; Sunglasses and related eyewear; Windows, windscreens and other safety glazing products Spectral transmittance Not applicable

SJ&A 4.4;

Eye protectors, filters and related eyewear for industrial applicationsfilters and surfaces Chromaticity Not applicable
General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; High intensity discharge lamps; LED and other solid state lighting sources; Lighting for roads and public spaces; Surgical and diagnostic lighting Distribution of luminous intensity Not applicable

IES LM-79;

CIE 121 ;

CIE S 025;

Luminaires with maximum light emitting dimension not exceeding 800 mm;

Excluding luminaires with discharge lamps;

Correlated colour temperature Not applicable

SJ&A 4.2;

SJ&A 10.2;

IES LM-79;

General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; High intensity discharge lamps; LED and other solid state lighting sources; Lighting for roads and public spaces; Surgical and diagnostic lighting; UVA lamps and UVC lamps Spectral irradiance Not applicable

SJ&A 4.2;

SJ&A 10.2;

IES LM-79

280nm to 830nm
General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sources; Lighting booths and lighting sources; Lighting for roads and public spaces Daylight simulators; Illuminance Not applicable

SJ&A 3.2.3

Field measurement of Illuminance in the range 0.5 to 3000 lux;

General lighting - LED and other solid state lamps; LED and other solid state lighting sources Luminous flux Direct measurement by goniophotometer; Direct measurement by integrating sphere by the methods of; SJ&A 7.5; SJ&A 10; IES LM-79; by the method of goniophotometry with physical dimensions no greater than 0.5 m x 0.5 m x 0.4 m (LxWxH) and by the method using an integrating sphere with luminous dimension no greater than 150 mm
Sunglasses and related eyewear Blue light transmittance; Bridge strength; Dimensions; Haze; Lens retention; Luminous transmittance; Prismatic power; Refractive power; Resistance to ignition; Robustness; Solar transmittance; Spectral transmittance; Spectral transmittance in the UV-vis spectrum; Ultraviolet transmittance Indirect measurement using a spectrophotometer and software integration; Measurement using a reference standard; Physical handling test; Visual examination AS/NZS 1067.1;
AS/NZS 1067.2;
Consumer Product Safety GN 37 - Sunglasses and fashion spectacles : 2017;

Not including photochromic sunglasses
Traffic signalling and warning signsincluding arrowboard lamps Chromaticity; Distribution of luminous intensity; Luminance Not applicable

AS/NZS 2144;

AS 4852.1;

 AS 4852.2;

 AS 4192;

 EN 12966-1;

AS 5156;

SJ&A 3.1.4; 

EN 12066-1;

Windows, windscreens and other safety glazing productsflat non-fluorescent materials Spectral reflectancediffuse reflectance Not applicable

by the methods of SJ&A 4.1.1;

Evaluation of consumer and industrial lighting, optical systems and eyewearField testing Distribution photometer mirrors Flatness; Relative luminous intensity; Spectral reflectance Not applicable

EN 13032-1 Annex C

Material performance evaluation of leather, textiles and related products Sun protective textiles and clothing; Synthetic shade cloth Spectral transmittance Visual comparison

SJ&A 4.4;

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.