National Measurement Institute (NMI)

Site

Trade Measurement Laboratory, Hobart

Accreditation No.

1

Site No.

14817

Date of Accreditation

Address

15A Lampton Avenue
Derwent Park, TAS 7009
Australia

measurement.gov.au

Contact

Availability

Services conditionally available to external clients

Scope of Accreditation

Withdrawn

Trade Measurement Laboratory, Hobart

ISO/IEC 17025 (2005)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
Flow metrology - Flow measuring devices and systems Liquid meters Flow rate

Master meters for water
for flow rates from 50 L/min up to and including 1000 L/min

Capability

with Calibration and Measurement Capability of-

0.05% of volume with a minimum 500 L test volume

Mass - Determination of mass and calibration of weighing devices Industrial mass standards Mass Gravimetric measurement against reference mass

From 100 g to 1200 kg


Capability

with Calibration and Measurement Capability of-

1 in 105 from 100 g up to 1200 kg

Mass

2 in 105 from 1 g up to 1200 kg

 
Industrial weighing devices Mass Gravimetric measurement against reference mass; Substitution gravimetric measurement

by the method and specification of National Instrument Test Procedures (NITP) 6.1–6.4

Capability

with Calibration and Measurement Capability of-

1 in 104 from 1 kg up to and including 30 t for direct loading and 150 t using the substitution method


Laboratory weighing devices; Precision laboratory balances Mass Gravimetric measurement against reference mass

From 1 mg to 1500 kg

Capability

with Calibration and Measurement Capability of-

Precision balances and laboratory weighing devices

3 μg from 1 mg up to 50 mg;
4 μg above 50 mg up to and including 0.2 g;
8 μg above 0.2 g up to and including 2 g;
15 μg above 2 g up to and including 10 g;
30 μg above 10 g up to and including 100 g;
4 in 107 above 100 g up to and including 40 kg

4 in 106 above 40 kg up to and including 500 kg

1 in 105 above 500 kg up to and including 1500 kg 


 

Mass standards Mass Gravimetric measurement against reference mass

From 1 mg to 50 kg

Capability

with Calibation and Measurement Capability of -

3 μg from 1 mg up to and including 10 mg;
5 μg above 10 mg up to and including 200 mg;
10 μg above 200 mg up to and including 2 g;
2 in 106 above 2 g up to and including 50 g;
1 in 106 above 50 g up to and including 25 kg;
6 in 106 above 25 kg up to and including 50 kg

Volume and density - Determination of density Density of liquids kg/m3 To be determined

500 kg/m3 to 1200 kg/m3

Capability

with Calibration and Measurement Capability of-

0.1%

Volume and density - Industrial volumetric equipment and bulk storage Bulk storage tanks; Industrial volumetric proving measures; Standard measures - > 25 L Volume

Proving tanks by standard measures
Proving tanks by gravimetric methods
From 1 L up to 1000 L

Standard measures 

From 2 L to 1000L

Industrial storage tanks of capacity greater than 500 L

 

Capability

with Calibration and Measurement Capability of-

Proving tanks by standard measures
1 in 104 from 1 L up to 5000 L


Proving tanks by gravimetric methods
10 in 104 from 1 L up to 1000 L

Standard Measures

7.5 in 105 from 2 L up to 1000 L

Industrial storage tanks
0.1%

Volume and density - Laboratory volumetric glassware and measures Standard measures - < 50 L; Volumetric glassware and measures Volume Gravimetric

Volumetric glassware and standard measures

From 0.1 mL to 2 L

Capability

with Calibration and Measurement Capability 0f-

2 in 103 or 0.001 mL (whichever is greater) from 0.1 mL up to 1 mL;
1 in 104 or 0.004 mL (whichever is greater) above 1 mL up to 2 L


The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.