TUV Rheinland Japan Ltd

Site

Yokohama Laboratory

Accreditation No.

14357

Site No.

21807

Date of Accreditation

Address

Global Technology Assessment Center, 4-25-2 Kita Yamata, Tsuzuki-ku, YOKOHAMA 224-0021
0
Japan

jpn.tuv.com

Contact

Mr John Ologbosere P: 81 459140223

Availability

Services available to external clients

Scope of Accreditation

Withdrawn

Yokohama Laboratory

ISO/IEC 17025 (2005)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators DC voltage Comparison with a reference standard in-house method MS-0020875

Capability

with Calibration and Measurement Capability of -
2.3 μV from 0 to 200 mV
2.6 μV from 0.2 V to 2 V
12 μV from 2 V to 20 V
0.15 mV from 20 V to 200 V
1.6 mV from 200 V to 1000 V

DC current Comparison with a reference standard in-house method MS-0020878

Capability

with Calibration and Measurement Capability of -

0.41 nA from 0 to 200 μA

6.5 nA from 0.2 to 2 mA

69 nA from 2 to 20 mA

1.8 μA from 20 to 200 mA

54 μA from 200 mA to 2 A

1.2 mA from 2 to 20 A
Resistance Comparison with a reference standard in-house method MS-0020976

Capability

with Calibration and Measurement Capability of -

4.1 μμ from 0 to 2 μ

34 μμ from 2 Ω to 20 μ

0.21 mμ from 20 Ω to 200 μ

2.1 mμ from 0.2 Ω to 2 kμ

21 mμ from 2 Ω to 20 kμ

0.21 μ from 20 Ω to 200 kμ

2.9 μ from 0.2 Ω to 2 Mμ

0.14 kμ from 2 MΩ to 20 Mμ 

13 kμ from 20 MΩ to 200 Mμ

1.3 Mμ from 0.2 GΩ to 2 Gμ 

13 Mμ from 2 GΩ to 20 Gμ

AC voltage Comparison with a reference standard in-house method MS-0020875

Capability

with Calibration and Measurement Capability of -

2 μV from 0.01 mV to 200 mV and 1 Hz to 100 kHz

26 μV from 0.2 V to 2 V and 1 Hz to 1 MHz

0.36 mV from 2 V to 20 V and 1 Hz to 1 MHz

3.6 mV from 20 V to 200 V and 1 Hz to 1 MHz

44 mV from 200 V to 1000 V and 1 Hz to 100 kHz
AC current Comparison with a reference standard in-house method MS-0020878

Capability

with Calibration and Measurement Capability of -

21 nA from 0 to 200 μA and 1 Hz to 100 kHz

0.27 μA from 0.2 mA to 2 mA and 1 Hz to 100 kHz

2.7 μA from 2 mA to 20 mA and 1 Hz to 100 kHz

26 μA from 20 mA to 200 mA and 1 Hz to 30 kHz

0.33 mA from 200 mA to 2 A and 10 Hz to 30 kHz

3.7 mA from 2 A to 20 A and 10 Hz to 10 kHz
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM) AC current Comparison with a reference standard in-house method MS-0020879

Capability

with Calibration and Measurement Capability of -

41 nA from 29 μA to 200 μA and 10 Hz to 30 kHz

0.34 μA from 0.2 mA to 2 mA and 10 Hz to 30 kHz

3.4 μA from 2 mA to 20 mA and 10 Hz to 30 kHz

34 μA from 20 mA to 200 mA and 10 Hz to 30 kHz

0.39 mA from 200 mA to 2 A and 10 Hz to 10 kHz

4.2 mA from 2 A to 3 A and 45 Hz to 10 kHz
5 mA from 3 A to 20 A and 45 Hz to 5 kHz
AC current Comparison with a reference standard 29 µA to 20 A and from 10 Hz to 30 kHz

Capability

with Calibration and Measurement Capability of -

1.6 mA/A + 76 nA from 29 µA to 200 µA and from 10 Hz to 20 Hz 

1.2 mA/A + 76 nA from 29 µA to 200 µA and from 20 Hz to 45 Hz

983 uA/A + 76 nA from 29 µA to 200 µA and from 45 Hz to 55 Hz

558 uA/A + 32 nA from 29 µA to 200 µA and from 55 Hz to 10  kHz 

745 uA/A + 32 nA from 29 µA to 200 µA and from 10 kHz to 30 kHz

1.6 mA/A + 76 nA from 200 µA to 330 µA and from 10 Hz to 20 Hz 

1.2 mA/A + 76 nA from 200 µA to 330 µA and from 20 Hz to 45 Hz

983 uA/A + 76 nA from 200 µA to 330 µA and from 45 Hz to 55 Hz

329 uA/A + 312 nA from 200 µA to 330 µA and from 55 Hz to 10 kHz 

711 uA/A + 312 nA from 200 µA to 330 µA and from 10 kHz to 30 kHz

1.1 mA/A + 1.7 uA from 330 µA to 2 mA and from 10 Hz to 20 Hz

568 uA/A + 1.7 uA from 330 µA to 2 mA and from 20 Hz to 45 Hz

410 uA/A + 1.7 uA from 330 µA to 2 mA and from 45 Hz to 55 Hz

329 uA/A + 312 nA from 330 µA to 2 mA and from 55 Hz to 10 kHz

711 uA/A + 312 nA from 330 µA to 2 mA and from 10 kHz to 30 kHz

1.1 mA/A + 1.7 uA from 2 mA to 3.3 mA and from 10 Hz to 20 Hz

568 uA/A + 1.7 uA from 2 mA to 3.3 mA and from 20 Hz to 45 Hz

410 uA/A + 1.7 uA from 2 mA to 3.3 mA and from 45 Hz to 1 kHz

414 uA /A + 3.2 uA from 2 mA to 3.3 mA and from 1 kHz to 10 kHz

745 uA /A + 3.2 uA from 2 mA to 3.3 mA and from 10 kHz to 30 kHz

1.4 mA/A + 1.8 uA from 3.3 mA to 20 mA and from 10 Hz to 20 Hz

722 uA/A + 1.8 uA from 3.3 mA to 20 mA and from 20 Hz to 45 Hz

382 uA/A + 1.8 uA from 3.3 mA to 20 mA and from 45 Hz to 55 Hz

414 uA/A + 3.2 uA from 3.3 mA to 20 mA and from 55 Hz to 10 kHz

745 uA/A + 3.2 uA from 3.3 mA to 20 mA and from 10 kHz to 30 kHz

1.4 mA/A + 1.8 uA from 20 mA to 33 mA and from 10 Hz to 20 Hz

722 uA/A + 1.8 uA from 20 mA to 33 mA and from 20 Hz to 45 Hz

382 uA/A + 1.8 uA from 20 mA to 33 mA and from 45 Hz to 1 kHz

649 uA/A + 1.8 uA from 20 mA to 33 mA and from 1 kHz to 5 kHz

321 uA/A + 31 uA from 20 mA to 33 mA and from 5 kHz to 10 kHz

628 mA/A + 31 uA from 20 mA to 33 mA and from 10 kHz to 30 kHz

1.4 mA/A + 16 uA from 33 mA to 200 mA and from 10 Hz to 20 Hz

723 uA/A + 16 uA from 33 mA to 200 mA and from 20 Hz to 45 Hz

371 uA/A + 16 uA from 33 mA to 200 mA and from 45 Hz to 55 Hz

321 uA/A + 31 uA from 33 mA to 200 mA and from 55 Hz to 10 kHz

628 uA/A + 31 uA from 33 mA to 200 mA and from 10 kHz to 30 kHz

1.4 mA/A + 16 uA from 200 mA to 330 mA and from 10 Hz to 20 Hz

723 uA/A + 16 uA from 200 mA to 330 mA and from 20 Hz to 45 Hz

371 uA/A + 16 uA from 200 mA to 330 mA and from 45 Hz to 1 kHz

796 uA/A + 39 uA from 200 mA to 330 mA and from 1 kHz to 5 kHz

1.6 mA/A + 76 uA from 200 mA to 330 mA and from 5 kHz to 10 kHz

3.1 mA/A + 155 uA from 200 mA to 330 mA and from 10 kHz to 30 kHz

231 uA/A + 1.7 mA from 330 mA to 1.1 A and from 10 Hz to 45 Hz

73 uA/A + 1.7 mA from 330 mA to 1.1 A and from 45 Hz to 55 Hz

624 uA/A + 312 uA from 330 mA to 1.1 A and from 55 Hz to 2 kHz

735 uA/A + 312 uA from 330 mA to 1.1 A and from 2 kHz to 10 kHz

731 uA/A + 2.6 mA from 1.1 A to 2 A and from 10 Hz to 45 Hz

402 uA/A + 2.3 mA from 1.1 A to 2 A and from 45 Hz to 55 Hz

624 uA/A + 312 uA from 1.1 A to 2 A and from 55 Hz to 2 kHz

735 uA/A + 312 uA from 1.1 A to 2 A and from 2 kHz to 10 kHz

731 uA/A + 2.6 mA from 2 A to 3 A and from 10 Hz to 45 Hz

402 uA/A + 2.3 mA from 2 A to 3 A and from 45 Hz to 55 Hz

849 uA/A + 3.2 mA from 2 A to 3 A and from 55 Hz to 2 kHz

2.5 mA/A + 3.2 mA from 2 A to 3 A and from 2 kHz to 10 kHz

975 uA/A + 4.1 mA from 3 A to 20 A and from 45 Hz to 55 Hz

849 uA/A + 3.2 mA from 3 A to 20 A and from 55 Hz to 2 kHz

 2.5 mA/A + 3.2 mA from 3 A  to 20 A and from 2 kHz to 10 kHz
DC current Comparison with a reference standard 0 to 20 A

Capability

with Calibration and Measurement Capability of -

140 µA/A + 7 nA from 0 A to 200 µA

140 µA/A + 14 nA from 0 .2 mA to 2  mA

140 µA/A + 0.6 µA from 2 mA to 20 mA

130 µA/A + 2.8 µA from 20 mA to 200 mA

186 µA/A + 31 µA from 200 mA to 1.1 A

208 µA/A + 29 µA from 1.1 A to 2 A

 348 μA/A + 2.9 mA from 2 A to 20 A
Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard 0 Ω to 1 GΩ

Capability

with Calibration and Measurement Capability of -

27 µμ/μ + 29 µμ from 0 μ to 2 μ

27 µμ/μ + 35 µμ from 2 μ to 20 μ

25 µμ/μ + 0.33 mμ from 20 μ to 200 μ

21 µμ/μ + 2.9 mμ from 200 μ to 2 kμ

21 µμ/μ + 29 mμ from 2 kμ to 20 kμ

32 µμ/μ + 0.29 μ from 20 kμ to 200 kμ

34 µμ/μ + 2.8 μ from 200 kμ to 2 Mμ

105 µμ/μ + 280 μ from 2 Mμ to 20 Mμ

2.1  mμ/μ + 28 kμ from 20 Mμ to 200 Mμ
5 mμ/μ + 100 kμ from 200 Mμ to 1 Gμ
Digital multimeters (DMM); Voltmeters AC voltage Comparison with a reference standard 10mV to 1000 V and from 20 Hz to 100 kHz

Capability

with Calibration and Measurement Capability of -

186 uV/V + 11 uV from 10 mV to 200 mV and 20 Hz to 40 Hz

174 uV/V + 11 uV from 10 mV to 200 mV and 40 Hz to 100 Hz

170 uV/V + 11 uV from 10 mV to 200 mV and 100 Hz to 2 kHz

184 uV/V + 11 uV from 10 mV to 200 mV and 2 kHz to 10 kHz

358 uV/V + 12 uV from 10 mV to 200 mV and 10 kHz to 30 kHz

787 uV/V + 22 uV from 10 mV to 200 mV and 30 kHz to 100 kHz

 

174 uV/V + 85 uV from 200 mV to 200 V and 20 Hz to 40 Hz

167 uV/V + 85 uV from 200 mV to 200 V and 40 Hz to 100 Hz

163 uV/V + 85 uV from 200 mV to 200 V and 100 Hz to 2 kHz

171 uV/V + 85 uV from 200 mV to 200 V and 2 kHz to 10 kHz

247 uV/V + 85 uV from 200 mV to 200 V and 10 kHz to 30 kHz

593 uV/V + 214 uV from 200 mV to 200 V and 30 kHz to 100 kHz

 

193 uV/V + 10 mV from 200 V to 330 V and 45 Hz to 55 Hz

263 uV/V + 10 mV from 330 V to 1000 V and 45 Hz to 55 Hz

175 uV/V + 63 mV from 200 V to 1000 V and 55 Hz to 10 kHz

251 uV/V + 68 mV from 200 V to 1000 V and 10 kHz to 30 kHz

DC voltage Comparison with a reference standard 0 V to 1000 V

Capability

with Calibration and Measurement Capability of -

5.4 µV/V + 2.4 µV from 0 mV to 200 mV

6.2 µV/V + 3.5 µV from 0.2 V to 2 V

6.1 µV/V + 28 µV from 2 V to 20 V

10 µV/V + 290 µV from 20 V to 200 V

 11  μV/V + 3.3 mV from 200 V to 1000 V
LCR meters Capacitance Comparison with a reference standard in-house method MS-0025852

Capability

with Calibration and Measurement Capability of -

8.6 pF from 220 pF to 400 pF

9.3 pF from 0.4 nF to 1.1 nF

12 pF from 1.1 nF to 3.3 nF

14 pF from 3.3 nF to 11 nF

97 pF from 11 nF to 33 nF

0.14 nF from 33 nF to 110 nF

0.44 nF from 110 nF to 330 nF

1.4 nF from 0.33 μF to 1.1 μF

4.4 nF from 1.1 μF to 3.3 μF

14 nF from 3.3 μF to 11 μF

57 nF from 11 μF to 33 μF

0.19 μF from 33 μF to 110 μF

0.62 μF from 110 μF to 330 μF

1.9 μF from 0.33 mF to 1.1 mF

6.2 μF from 1.1 mF to 3.3 mF

19 μF from 3.3 mF to 11 mF

87 μF from 11 mF to 33 mF

0.36 mF from 33 mF to 110 mF
In-situ verification of controlled enclosures Environmental chambers - Humidity Humidity By temperature and humidity measurement in-house method MS-0021069

Capability

2.02%RH from ???? °C to ???? °C and in the range 20%RH to 80%RH
2.88%RH from ???? °C to ???? °C and in the range 80%RH to 95%RH
Environmental chambers - Temperature Temperature Direct temperature measurement in-house method MS-0021069

Capability

with Calibration and Measurement Capability of -
0.62 ºC from -40.0 ºC to 0 ºC
0.4 ºC above 0.0 ºC to 300 ºC
Temperature metrology - Ancillary temperature measuring equipment Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders Resistance to temperature conversion; Volt to temperature conversion Direct measurement by electrical input

Thermocouples by electrical simulation

-210 ºC to 1372 ºC

PRTs by electrical simulation

-200 °C to 800 °C

Capability

PT100

with Calibration and Measurement Capability of -

39 mK from -200 ºC to 0 ºC

54 mK from 0 ºC to 100 ºC

70 mK from 100 ºC to 300 ºC

77 mK from 300 ºC to 400 ºC

93 mK from 400 ºC to 630 ºC

178 mK from 630 ºC to 800 ºC

PT1000

with Calibration and Measurement Capability of -

23 mK from -200 ºC to 0 ºC

31 mK from 0 ºC to 100 ºC

39 mK from 100 ºC to 260 ºC

46 mK from 260 ºC to 300 ºC

54 mK from 300 ºC to 600 ºC

178 mK from 600 ºC to 630 ºC

Type J

with Calibration and Measurement Capability of -

0.25 K from -210 ºC to -100 ºC

0.21 K from -100 ºC to -30 ºC

0.12 K from -30 ºC to 150 ºC

0.14 K from 150 ºC to 760 ºC

0.19 K from 760 ºC to 1200 ºC

Type K

with Calibration and Measurement Capability of -

0.31 K from -200 ºC to -100 ºC

0.25 K from -100 ºC to -25 ºC

0.14 K from -25 ºC to 120 ºC

0.21 K from 120 ºC to 1000 ºC

0.32 K from 1000 ºC to 1372 ºC

Type T

with Calibration and Measurement Capability of -

0.51 K from -250 ºC to -150 ºC

0.2 K from -150 ºC to 0 ºC

0.14 K from 0 ºC to 120 ºC

0.12 K from 120 °C to 400 °C
Temperature metrology - Temperature measuring equipment Base metal thermocouples mV over oC range Direct temperature and electrical measurement against reference standard in-house method MS-0021070

Capability

with Calibration and Measurement Capability of -
0.31 ºC from -30.0 ºC to 0 ºC 
0.3 ºC above 0 ºC to 100 ºC
0.24 ºC above 100 ºC to 400 ºC
Digital temperature measuring systems mV over oC range Direct temperature and electrical measurement against reference standard in-house method MS-0021071

Capability

Thermocouple indicator systems 
with Calibration and Measurement Capability of -
0.49 ºC from -250.0 ºC to -210 ºC 
0.21 ºC above -210.0 ºC to -150 ºC 
0.19 ºC above -150.0 ºC to -100 ºC 
0.12 ºC above -100.0 ºC to -30 ºC 
0.11 ºC above -30.0 ºC to 400 ºC
0.13 ºC above 400 ºC to 760 ºC
0.18 ºC above 760 ºC to 1200 ºC
0.31 ºC above 1200 ºC to 1372 ºC
Resistance over oC range Direct temperature and electrical measurement against reference standard in-house method MS-0021071

Capability

PRT indicator systems
with Calibration and Measurement Capability of -
0.023 ºC from -200.0 ºC to 0 ºC
0.031 ºC above 0 ºC to 100 ºC
0.039 ºC above 100 ºC to 260 ºC
0.046 ºC above 260 ºC to 300 ºC
0.054 ºC above 300 ºC to 600 ºC
0.093 ºC above 600 ºC to 630 ºC
0.18 ºC above 630 ºC to 800 ºC
Metallic resistance thermometers Resistance over oC range Direct temperature and electrical measurement against reference standard in-house method MS-0021070

Capability

with Calibration and Measurement Capability of -
0.2 ºC from -30.0 ºC to 0 ºC 
0.19 ºC above 0 ºC to 100 ºC
0.22 ºC above 100 ºC to 400 ºC
Time and frequency metrology - Frequency, time and waveform measuring equipment Frequency meters Frequency Measurement against reference standard in-house method MS-0020876

Capability

with Calibration and Measurement Capability of -
5.8 mHz from 0.01 Hz to 2 MHz

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.