Back to Withdrawn Sites List


Scope of Accreditation Withdrawn-   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar consistence in-situ
Concrete, grout and mortar;
Slump flow;
Cone; T500;
AS 1012.3.1, AS 1012.3.5, ASTM C1611
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar properties
Concrete, grout and mortar;
Mass per unit volume - Fresh concrete;
In-situ measurement using fixed volume measure;
AS 1012.5


Mass per unit volume - Hardened concrete;
Dimensions; Water displacement;
AS 1012.12.1, AS 1012.12.2


Compressive strength;
Cylinder;
AS 1012.9 (except clause 4.2)


Air content of freshly mixed concrete;
Reduced air pressure;
AS 1012.4.2


Flexural strength;
Modulus of rupture;
AS 1012.11
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar specimen manufacture and curing
Concrete, grout and mortar;
Specimen manufacture and curing;
Curing cylinder specimens in the laboratory; In-situ manufacture and curing of cylindrical specimens; In-situ manufacture and curing of drying shrinkage specimens; In-situ manufacture and curing of flexural strength specimens;
AS 1012.8.1, AS 1012.8.2, AS 1012.8.4
Sample collection
Concrete, grout and mortar;
Not applicable;
Fresh concrete from a mixer; Fresh concrete from deposited concrete;
AS 1012.1