National Association of Testing Authorities, Australia
Scope of Accreditation
Accredited Test Services
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Force metrology - Force measuring and testing equipment | Load cells | Force in compression; Force in tension | Comparison measurement with reference load cell |
From 1 kN to 90 kN |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability With calibration and measurement capability of- 0.5 % of reading From 1 kN to 90 kN |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Pressure transducers | Gauge pressure | By pressure calibrator; Comparison with dead weight tester; Comparison with reference instrument | AS 1349 | 10 kPa to 120 MPa | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with calibration and measurement capability of - 0.06% of reading from 10 kPa to 120 MPa |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Piezoelectric pressure transducer (blast pencils); Pressure transducers | Dynamic pressure | Comparison with a reference transducer | from 3.5 kPa (0.5psi) to 345 kPa (50psi) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with calibration and measurement capability of -1% of reading from 3.5 kPa to 345 kPa |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Vibration metrology - Vibration equipment | Accelerometers; Vibration measuring systems | Acceleration sensitivity | Comparison measurement against reference transducer |
from 9.8 m/s2 to 490 m/s2 (1 to 50 gn) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with calibration and measurement capability of - Calibration of accelerometers of mass less than 100 g 0.8% of sensitivity from 11 Hz to 5000 Hz |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Measurement of sound levels in workplaces and the environment | Electrical machinery; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Road traffic; Weapons | Sound pressure level | Microphone |
QDAL-INST-103, QDAL-INST-105, QDAL-INST-107, QDAL-INST-108, |
|
| Environments impacted by noise or vibration; Occupied spaces | Community noise assessments; Occupational noise exposure level | Microphone |
QDAL-INST-104 |
||
| Vibration analysis - Vibration levels in workplaces and the environment | Electrical machinery; Environments impacted by noise or vibration; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Motor vehicles; Occupied spaces | Vibration exposure; Vibration level | Geophone | QDAL-INST-101, QDAL-INST-102 |
ISO/IEC 17025 (2017)
Manufactured Goods
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Electromagnetic compatibility (EMC) - Emissions - Military | Electrical and electronic products | Conducted emissions | Not applicable | MIL-STD-461 D, E, F, G; Method CE 102 | CE 102 Conducted emissions, power leads, 10 kHz to 10 MHz |
| Radiated emissions | Not applicable | MIL-STD-461 D, E, F, G; Method RE 102 | RE 102 Radiated emissions, electric field at 1 m; 10 kHz to 18 GHz | ||
| Electromagnetic compatibility (EMC) - Immunity - Military | Electrical and electronic products; Power leads | Radiated susceptibility | Not applicable | MIL-STD-461 D, E, F; G; Method RS 101, RS 103 |
RS 101 Radiated susceptibility, magnetic field, 30 Hz to 100 kHz; RS 103 Radiated susceptibility, electric field, 10 Hz to 18 GHz |
| Conducted susceptibility | Not applicable | MIL-STD-461 D, E, F, G: Methods CS 101, CS 114, CS 115, CS 116 |
CS 101 Conducted susceptibility, power leads, 30 Hz to 50 kHz; CS 114 Conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz; CS 116 Conducted susceptibility, bulk cable injection, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz |
||
| Evaluation of consumer and industrial lighting, optical systems and eyewear | Image intensification devices | Resolution | USAF test pattern |
QECL-INST-O01 |
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.
Accreditation No.
502
Site No.
495
Print date
24 Aug 2026