Acoustic Research Labs Pty Ltd

Site

Acoustic Research Labs Pty Ltd

Accreditation No.

14172

Site No.

14165

Date of Accreditation

11 Feb 1999

Address

36/14 Loyalty Road
North Rocks, NSW 2151
Australia

acousticresearch.com.au

Contact

Mr Ken Williams P: +61 (02) 94840800

Availability

Services available to external clients

Scope of Accreditation

Acoustic Research Labs Pty Ltd

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Acoustical metrology - Acoustic equipment Band pass filters Frequency response; Linearity Direct measurement by electrical input IEC-61260-3



Capability

With Calibration and Measurement Capability of -
0.1 dB from -5 dB ≤A ≤ 40 dB
0.2 dB from 40 dB < A ≤ 120 dB
0.10 dB for relative attenuation at midband frequency
0.10 dB for linear operating range
0.10 dB for lower limit of linear operating range
Sound level meters Electrical response; Sound pressure level Direct measurement by electrical input; Direct measurement by reference sound source

AS 1259.1 - 1990 Clauses 8.9, 8.10, 10.1, 10.2.2, 10.2.3, 10.3.2, 10.3.3, 10.3.4, 10.4.2, 10.4.3, 10.4.4, 10.4.5

AS 1259.2 - 1990 Clauses 9.1, 9.2.1, 9.2.2, 9.2.3, 9.3.1, 9.3.2, 9.3.3, 9.3.5

IEC 60651:1979 Amdt 2, IEC 60804:2000; IEC 61672-3

Capability

With Calibration and Measurement Capability of - 

Acoustic tests using a multi function acoustic calibrator
0.14 dB at 31.5 Hz
0.13 dB at 63 Hz to 125 Hz  
0.12 dB at 250 Hz to 500 Hz
0.13 dB at 1 kHz to 2 kHz
0.14 dB at 4 kHz to 8 kHz
0.16 dB at 12.5 kHz
0.22 dB at 16 kHz


Electrical tests
0.1 dB from 10 Hz to 24 kHz


Acoustical metrology - Acoustic standards and reference equipment Acoustic calibrators - Multi frequency Distortion; Frequency; Sound pressure level Direct measurement against reference signal IEC 60942

Capability

With Calibration and Measurement Capability of -
0.10 dB at 250 Hz and 1 kHz for sound pressure level
0.07% for frequency
0.2% for total harmonic distortion and noise

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.