National Association of Testing Authorities, Australia
Scope of Accreditation
A. NOBLE & SON PTY LTD
Site
Adelaide Laboratory
Accreditation No.
332
Site No.
325
Date of Accreditation
15 Nov 1960
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of geometric properties of structures and equipment | Structures and assemblies | Weight | Not applicable | in-house method WT026 | 5 to 1,500 kN |
Evaluation of load generating lifting appliances | Cranes; Jibs and suspension equipment; Serial and lever hoists; Winches | Proof load | Not applicable | AS 1418.2 AS 1418.3 AS 1418.5 AS 4991 in-house method WT029 | 5 to 9,810 kN on-site tests in the range 5 to 1,500 kN |
Evaluation of load handling, rigging and tensioning systems | C-hooks; Eye hooks; Shank hooks | Proof load | Not applicable | AS 3777 in-house method WT029 | 5 to 9 810 kN tests in the range 5 to 1500 kN |
Chain | Breaking load; Proof load | Not applicable | AS 2321 F1 and F2 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Chain slings | Breaking load; Proof load | Not applicable | AS 3775.1 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Containers; Nets (for unloading cargo); Pallets | Proof load | Not applicable | in-house method WT029 | 5 to 1,500 kN | |
Detaching hooks | Breaking load; Extension; Proof load | Not applicable | AS 3637.2 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Eye bolts | Breaking load; Extension; Proof load | Not applicable | AS 2317.1 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Fibre rope slings | Breaking load; Proof load | Not applicable | AS 1380.1 (1998) | Breaking load tests: 20 to 9 810 kN Proof load tests: 6 to 9 810 kN | |
Fittings | Breaking load; Extension; Proof load | Not applicable | AS 3776 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Girder clamps; Lifting and spreader beams; Trolleys | Proof load | Not applicable | AS 1418.2 AS 1418.3 AS 1418.5 AS 4991 in-house methods: WT 029 | 5 to 9,810 kN on site tests in the range 5 to 1500 kN | |
Lifting assemblies | Proof load | Not applicable | in-house method WT029 | 5 to 9,810 kN | |
Lifting clutches for concrete elements | Proof load | Not applicable | AS 3850.1 clause 2.6 | 10 kN to 9810kN on-site tests in the range 10 kN to 300 kN | |
Plate clamps and gripping devices | Breaking load; Extension; Proof load | Not applicable | AS 2076; AS 4991 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Rigging screws and turnbuckles | Breaking load; Extension; Proof load | Not applicable | AS 2319 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Shackles | Breaking load; Extension; Proof load | Not applicable | AS 2741 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Sheave blocks | Breaking load; Extension; Proof load | Not applicable | AS 2089 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Swivels | Breaking load; Extension; Proof load | Not applicable | AS 3637.5 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Synthetic fibre roundslings | Breaking load; Proof load | Not applicable | AS 4497 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Synthetic webbing flat slings | Breaking load; Proof load | Not applicable | AS 1353.1 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Thimbles for wire rope | Breaking load; Extension; Proof load | Not applicable | AS 1138 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Wedge type sockets | Breaking load; Extension; Proof load | Not applicable | AS 2740 | Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN | |
Wire rope | Breaking load; Proof load | Not applicable | AS 3569 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Wire rope slings | Breaking load; Proof load | Not applicable | AS 1666.1 | Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN | |
Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) | Wire rope | Corrosion; Detection of broken wires; Material loss; Mechanical damage and wear | Not applicable | ||
Non-destructive testing (NDT) - Visual testing - During service life | Wire rope | Corrosion; Detection of broken wires; Fretting; Mechanical damage and wear | Visual testing |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
332
Site No.
325
Print date
26 Nov 2024