A. Noble & Son Limited (Nobles)

Site

Adelaide Laboratory

Accreditation No.

332

Site No.

325

Date of Accreditation

15 Nov 1960

Address

24 Kaurna Ave
Edinburgh, SA 5111
Australia

nobles.com.au

Contact

- - Sales P: +61 (08) 81696688

Availability

Services available to external clients

Scope of Accreditation

Adelaide Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of geometric properties of structures and equipment Structures and assemblies Weight Not applicable

in-house method WT026

5 to 1,500 kN

Evaluation of load generating lifting appliances Cranes; Jibs and suspension equipment; Serial and lever hoists; Winches Proof load Not applicable

AS 1418.2

AS 1418.3

AS 1418.5

AS 4991

in-house method WT029

5 to 9,810 kN  

on-site tests in the range 5 to 1,500 kN

Evaluation of load handling, rigging and tensioning systems C-hooks; Eye hooks; Shank hooks Proof load Not applicable

AS 3777

in-house method WT029

5 to 9 810 kN

tests in the range 5 to 1500 kN

Chain Breaking load; Proof load Not applicable

AS 2321 F1 and F2

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Chain slings Breaking load; Proof load Not applicable

AS 3775.1

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Containers; Nets (for unloading cargo); Pallets Proof load Not applicable

in-house method WT029

5 to 1,500 kN

Detaching hooks Breaking load; Extension; Proof load Not applicable

AS 3637.2

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Eye bolts Breaking load; Extension; Proof load Not applicable

AS 2317.1

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Fibre rope slings Breaking load; Proof load Not applicable

AS 1380.1 (1998)

Breaking load tests: 20 to 9 810 kN

Proof load tests: 6 to 9 810 kN

Fittings Breaking load; Extension; Proof load Not applicable

AS 3776

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Girder clamps; Lifting and spreader beams; Trolleys Proof load Not applicable

AS 1418.2

AS 1418.3

AS 1418.5

AS 4991

in-house methods: WT 029

5 to 9,810 kN  

on site tests in the range 5 to 1500 kN

Lifting assemblies Proof load Not applicable

in-house method WT029

5 to 9,810 kN

Lifting clutches for concrete elements Proof load Not applicable

AS 3850.1 clause 2.6

10 kN to 9810kN

on-site tests in the range 10 kN to 300 kN 

Plate clamps and gripping devices Breaking load; Extension; Proof load Not applicable AS 2076; AS 4991

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Rigging screws and turnbuckles Breaking load; Extension; Proof load Not applicable

AS 2319

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Shackles Breaking load; Extension; Proof load Not applicable

AS 2741

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Sheave blocks Breaking load; Extension; Proof load Not applicable

AS 2089

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Swivels Breaking load; Extension; Proof load Not applicable

AS 3637.5

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Synthetic fibre roundslings Breaking load; Proof load Not applicable

AS 4497

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Synthetic webbing flat slings Breaking load; Proof load Not applicable

AS 1353.1

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Thimbles for wire rope Breaking load; Extension; Proof load Not applicable

AS 1138

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Wedge type sockets Breaking load; Extension; Proof load Not applicable

AS 2740

Breaking load tests: 10 to 9,810 kN

Proof load tests: 5 to 9,810 kN

Wire rope Breaking load; Proof load Not applicable

AS 3569

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Wire rope slings Breaking load; Proof load Not applicable

AS 1666.1

Breaking load tests: 20 to 9,810 kN

Proof load tests: 6 to 9,810 kN

Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) Wire rope Corrosion; Detection of broken wires; Material loss; Mechanical damage and wear Not applicable
Non-destructive testing (NDT) - Visual testing - During service life Wire rope Corrosion; Detection of broken wires; Fretting; Mechanical damage and wear Visual testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.