ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of geometric properties of structures and equipment | Structures and assemblies | Weight | Not applicable |
in-house method WT026 |
5 to 1,500 kN |
Evaluation of load generating lifting appliances | Cranes; Jibs and suspension equipment; Serial and lever hoists; Winches | Proof load | Not applicable |
AS 1418.2 AS 1418.3 AS 1418.5 AS 4991 in-house method WT029 |
5 to 9,810 kN on-site tests in the range 5 to 1,500 kN |
Evaluation of load handling, rigging and tensioning systems | C-hooks; Eye hooks; Shank hooks | Proof load | Not applicable |
AS 3777 in-house method WT029 |
5 to 9 810 kN tests in the range 5 to 1500 kN |
Chain | Breaking load; Proof load | Not applicable |
AS 2321 F1 and F2 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Chain slings | Breaking load; Proof load | Not applicable |
AS 3775.1 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Containers; Nets (for unloading cargo); Pallets | Proof load | Not applicable |
in-house method WT029 |
5 to 1,500 kN |
|
Detaching hooks | Breaking load; Extension; Proof load | Not applicable |
AS 3637.2 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Eye bolts | Breaking load; Extension; Proof load | Not applicable |
AS 2317.1 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Fibre rope slings | Breaking load; Proof load | Not applicable |
AS 1380.1 (1998) |
Breaking load tests: 20 to 9 810 kN Proof load tests: 6 to 9 810 kN |
|
Fittings | Breaking load; Extension; Proof load | Not applicable |
AS 3776 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Girder clamps; Lifting and spreader beams; Trolleys | Proof load | Not applicable |
AS 1418.2 AS 1418.3 AS 1418.5 AS 4991 in-house methods: WT 029 |
5 to 9,810 kN on site tests in the range 5 to 1500 kN |
|
Lifting assemblies | Proof load | Not applicable |
in-house method WT029 |
5 to 9,810 kN |
|
Lifting clutches for concrete elements | Proof load | Not applicable |
AS 3850.1 clause 2.6 |
10 kN to 9810kN on-site tests in the range 10 kN to 300 kN |
|
Plate clamps and gripping devices | Breaking load; Extension; Proof load | Not applicable | AS 2076; AS 4991 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Rigging screws and turnbuckles | Breaking load; Extension; Proof load | Not applicable |
AS 2319 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Shackles | Breaking load; Extension; Proof load | Not applicable |
AS 2741 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Sheave blocks | Breaking load; Extension; Proof load | Not applicable |
AS 2089 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Swivels | Breaking load; Extension; Proof load | Not applicable |
AS 3637.5 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Synthetic fibre roundslings | Breaking load; Proof load | Not applicable |
AS 4497 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Synthetic webbing flat slings | Breaking load; Proof load | Not applicable |
AS 1353.1 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Thimbles for wire rope | Breaking load; Extension; Proof load | Not applicable |
AS 1138 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Wedge type sockets | Breaking load; Extension; Proof load | Not applicable |
AS 2740 |
Breaking load tests: 10 to 9,810 kN Proof load tests: 5 to 9,810 kN |
|
Wire rope | Breaking load; Proof load | Not applicable |
AS 3569 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Wire rope slings | Breaking load; Proof load | Not applicable |
AS 1666.1 |
Breaking load tests: 20 to 9,810 kN Proof load tests: 6 to 9,810 kN |
|
Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) | Wire rope | Corrosion; Detection of broken wires; Material loss; Mechanical damage and wear | Not applicable | ||
Non-destructive testing (NDT) - Visual testing - During service life | Wire rope | Corrosion; Detection of broken wires; Fretting; Mechanical damage and wear | Visual testing |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.