Advanced Inspection & NDT Pty Ltd

Site

Advanced Inspection & NDT Pty Ltd

Accreditation No.

20229

Site No.

24037

Date of Accreditation

03 Aug 2017

Address

53A Cambridge Street
Penshurst, NSW 2222
Australia

andt.com.au

Contact

Mr Mike Shun Ma P: +61 0425253761

Availability

Services available to external clients

Scope of Accreditation

Advanced Inspection & NDT Pty Ltd

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Limitations
Non-destructive testing (NDT) - Material properties and internal integrity Bonded metals; Castings - Austenitic stainless steel and duplex metals; Castings - Cast irons, steel and alloy steels; Castings - Non-ferrous metals and alloys; Welded joints - Clad and overlaid steel; Welded joints - Copper and copper-nickel alloys; Welded joints - Ferritic materials; Welded joints - Stainless steel, austenitic and duplex materials; Welded joints - Titanium and titanium alloys Radiographic detection and characterisation of discontinuities Film radiography
Bonded metals; Castings - Cast irons, steel and alloy steels; Rolled or wrought aluminium products; Rolled or wrought steel products; Welded joints - Ferritic materials; Welded joints - Stainless steel, austenitic and duplex materials Ultrasonic detection and characterisation of discontinuities A-scan capability
Non-destructive testing (NDT) - Product profile and corrosion mapping Metallic piping; Metallic plate; Metallic tubes - Ferromagnetic materials; Metallic tubes - Non-ferromagnetic materials Ultrasonic material thickness - Spot or grid measurements A-scan - Manual; Thickness meter
Ultrasonic material profiling and characterisation of material loss A-scan - Manual
Non-destructive testing (NDT) - Surface techniques Coatings Coating thickness High frequency eddy current
Metallic surfaces Dye penetrant detection of discontinuities Solvent removable; Water washable
Visual detection of discontinuities (prior to initial service) - Welded joints Visual examination
Magnetic particle detection of discontinuities AC magnetic flow

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.