National Association of Testing Authorities, Australia
Scope of Accreditation
AmSpec Australia Pty Ltd
Site
AmSpec Technical Services
Accreditation No.
20314
Site No.
9468
Date of Accreditation
03 May 1994
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Volume and density - Industrial volumetric equipment and bulk storageincluding on site calibrations | Bulk storage tanks | Volume | Comparison with a reference meter; Scanning length measurement; Strapping length method | Calibration of upright cylindrical tanks, by an optical reference line method or a laser total station method to ISO 7507-1, ISO 7507-2 and API 653 Calibration of upright cylindrical tanks, by 3D laser scanner Calibration of horizontal and inclined cylindrical steel tanks Calibration of horizontal and inclined cylindrical steel tanks by 3D laser scanner Calibration of vertical, horizontal and inclined cylindrical steel tanks and spherical and spheroid tanks by liquid calibration methods Calibration of spherical and spheroid tanks by strapping or 3D Laser scanner | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations with Calibration and Measurement Capability of - Upright cylindrical tanks by an optical reference line method or a laser total station method Upright cylindrical tanks by 3D laser scanner 0.06% of volume from 5000 kL to 40 ML Horizontal and inclined cylindrical steel tanks 0.32% of volume from 1 kL to 150 kL Vertical, horizontal and inclined cylindrical steel thanks and spherical and spheroid tanks 0.25% of volume from 20 L to 100 kL Calibration of spherical and spheroid tanks by strapping or 3D Laser scanner |
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of low pressure oil and gas pipelines | Low pressure oil and gas pipelines | Hydrostatic pressure | Not applicable | AS/NZS 2566.2 Appendix M except visco-elastic pressure pipelines to Appendix M5, AS 2885.5 | in the range 0 to 3000 kPa |
Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Hydrostatic pressure | Not applicable | AS 2117, AS 2683 (in-service performance tests), OCIMF guidelines | in the range 0 to 3000 kPa |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20314
Site No.
9468
Print date
25 Nov 2024