AMT Group Australasia (Melbourne)

Site

AMT – Melbourne

Accreditation No.

20596

Site No.

24688

Date of Accreditation

07 Feb 2020

Address

Unit 15, 69 Acacia Road
Ferntree Gully, VIC 3156
Australia

amtintlgroup.com.au

Contact

Mr Cameron Welch P: +61 0431237038

Availability

Services available to external clients

Scope of Accreditation

AMT – Melbourne

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Biological safety cabinets Inward air velocity Cold DOP AS 1807 clause 4.8,

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),

Biological safety cabinets; Cytotoxic drug safety cabinets Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1,

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets),

Ultraviolet intensity Not applicable AS 1807 clause 4.10 for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets)
Air barrier containment Cold DOP AS 1807 clause 4.9
for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
 AS 2252.5 (Cytotoxic safety cabinets)
Sound level Not applicable AS 1807 clause 4.7,

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets),

Work zone integrity Cold DOP

AS 1807 clause 4.3

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets)
Integrity of HEPA filter installations Cold DOP AS 1807.7,
AS 1807 clause 4.4,

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets),
AS 4260 clause 5.2,

Illuminance Not applicable AS 1807 clause 4.5,

for compliance with:
AS 2252.1 (2002), AS 2252.2 (Biological safety cabinets),
AS 2252.5 (Cytotoxic safety cabinets),

Clean rooms, pharmaceutical isolators and work stations Work zone integrity Cold DOP AS 1807 clause 4.3 for compliance with:
AS 2252.6 (Clean Workstation),
AS ISO 14644.1 (Clean Room),
AS ISO 14644.3 (Clean Room)
Sound level Not applicable AS 1807 Clause 4.7
AS 1807.16
for compliance with:
AS 2252.6 (Clean Workstation),
AS ISO 14644.1 (Clean Room),
AS ISO 14644.3 (Clean Room)
Integrity of HEPA filter installations Cold DOP AS 1807.7,
AS 1807 clause 4.4,
AS ISO 14644.3 Method B.7
for compliance with:
AS 2252.6 (Clean Workstation),
AS 4260 clause 5.2,
AS 4273 clause 9.3 (Pharmaceutical isolators),
AS ISO 14644.1 (Clean Room),
AS ISO 14644.3 (Clean Room)
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 for compliance with:
AS 2252.6 (Clean Workstation),
AS 4273 clause 9.4 (Pharmaceutical isolators)
Illuminance Not applicable AS 1807 clause 4.5 for compliance with:
AS 2252.6 (Clean Workstation),
AS ISO 14644.1 (Clean Room),
AS ISO 14644.3 (Clean Room)
Fume cupboards and recirculating fume cabinets Extraction performance Face velocity AS/NZS 2243.8 Appendix B,
AS/NZS 2243.9 Appendix B

for compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Extraction performance Smoke visualisation AS/NZS 2243.8 Appendix A,
AS/NZS 2243.9 Appendix A
for compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Sound level Not applicable AS 1807 clause 4.7 for compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Illuminance Not applicable AS 1807 clause 4.5 for compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.