Aquamonix

Site

Aquamonix

Accreditation No.

17094

Site No.

18674

Date of Accreditation

13 Apr 2010

Address

268 Milperra Road
Milperra, NSW 2214
Australia

aquamonix.com.au

Contact

Mr Jefferson Chung P: +61 (02) 86300910

Availability

Services available to external clients

Scope of Accreditation

Aquamonix

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Flow metrology - Water flow measuring devices and systems Liquid meters; Open channel water meters Flow rate; Volume (and nominal flow rate) Gravimetric

Capability

Gravimetric calibration of flow meters with bore diameters of 50 mm to 200 mm

With Calibration and Measurement Capability of -

0.14% of volume over a minimum measured volume of 3000 L

using water as the transfer medium at flow rates from 3.5 L/s up to 150 L/s

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.