Scope of Accreditation

Australian Calibration and Testing Services Pty Ltd

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators AC current; AC voltage; DC current; DC voltage; Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -
DC Voltage
60 μV/V from 10 mV up to 50 mV
20 μV/V above 50 mV up to 100 mV
12 μV/V above 100 mV up to 300 mV
10 μV/V above 300 mV up to 30 V
10 μV/V above 30 V up to 1000 V

AC Voltage
from 0.01 V up to 0.03 V
1.2 mV/V from 50 Hz up to 10 kHz
3.2 mV/V above 10 kHz up to 100 kHz
from 0.03 V up to 0.10 V
0.67 mV/V from 50 Hz up to 10 kHz
0.93 mV/V above 10 kHz up to 100 kHz
from 0.10 mV up to 1 V
0.60 mV/V from 50 Hz up to 10 kHz
2.2 mV/V above 10 kHz up to 100 kHz
from 1 V up to 100 V
2.2 mV/V from 50 Hz up to 10 kHz
4.0 mV/V above 10 kHz up to 100 kHz
from 100 V up to 1000 V
0.32 mV/V from 50 Hz up to 1 kHz
0.51 mV/V above 1 kHz up to 10 kHz
DC Current
0.10 mA/A from 10 μA up to 100 μA
0.25 mA/A above 100 μA up to 100 mA
0.65 mA/A above 100 mA up to 1 A
0.44 mA/A above 1 A up to 10 A
0.33 mA/A above 10 A up to 20 A

AC Current 
from 30 μA to 100 μA 
0.7 mA/A from 50 Hz up to 5 kHz
above 100 μA to 1 mA 
0.6 mA/A from 50 Hz up to 5 kHz
above 1 mA to 100 mA 
0.7 mA/A from 50 Hz up to 10 kHz
above 100 mA to 1 A 
0.41 mA/A from 50 Hz up to 1 kHz
above 1 A to 10 A 
0.92 mA/A from 50 Hz up to 1 kHz
above 10 A to 20 A 
1.5 mA/A from 50 Hz up to 1 kHz

Resistance
16 µΩ/Ω from 1 Ω up to 100 Ω
20 μΩ/Ω above 100 Ω up to 1 kΩ
21 μΩ/Ω above 1 kΩ up to 10 kΩ
13 μΩ/Ω above 10 kΩ up to 100 kΩ
0.11 mΩ/Ω above 100 μΩ up to 1 MΩ
0.18 mΩ/Ω above 1 MΩ up to 10 MΩ
0.75 mΩ/Ω above 10 MΩ up to 100 MΩ
10 mΩ/Ω above 100 MΩ up to 1 GΩ
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Current clamps; Digital multimeters (DMM); Ohm meters; Voltmeters AC current; AC voltage; DC current; DC voltage; Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
DC Voltage 
0.28 mV/V above 0 mV up to 50 mV
0.11 mV/V above 50 mV up to 100 mV
71 μV/V above 100 mV up to 300 mV
50 μV/V above 300mV up to 300 V
44 μV/V above 300 V up to 1000 V
AC Voltage
From 0.01 V to 0.03 V
2.3 mV/V at 50 Hz up to 10 kHz
3.1 mV/V above 10 kHz up to 50 kHz
5.2 mV/V above 50 kHz up to 100 kHz
From 0.03 V to 0.1 V
1.3 mV/V at 50 Hz up to 10 kHz
2.7 mV/V above 10 kHz up to 50 kHz
3.7 mV/V above 50 kHz up to 100 kHz
above 0.1 V to 1 V
0.4 mV/V at 50 Hz up to 10 kHz
1.1 mV/V above 10 kHz up to 50 kHz
3.1 mV/V above 50 kHz up to 100 kHz
above 1 V to 100 V
0.30 mV/V at 50 Hz up to 10 kHz
0.82 mV/V from 10 kHz up to 50 kHz
1.9 mV/V from 50 kHz up to 100 kHz
above 100 V to 300 V
0.42 mV/V at 50 Hz up to 1 kHz
0.99 mV/V above 1 kHz up to 50 kHz
2.5 mV/V above 50 kHz up to 100 kHz
above 300 V to 1000 V
0.43 mV/V at 50 Hz up to 1 kHz
0.73 mV/V above 1 kHz up to 10 kHz

DC Current
1.7 mA/A from 10 μA up to 100 μA
0.27 mA/A above 100 μA up to 1 mA
0.12 mA/A above 1 mA up to 10 mA
97 μA/A above 10 mA up to 100 mA
0.12 mA/A above 100 mA up to 1 A
0.66 mA/A above 1 A up to 10 A
0.80 mA/A above 10 A up to 20 A

AC Current
from 50 μA to 100 μA
0.06 A/A from 45 Hz up to 5 kHz
from 100 μA to 1 mA
3.6 mA/A from 45 Hz up to 5 kHz
from 1 mA to 10 mA
1.8 mA/A from 45 Hz up to 5 kHz
from 10 mA to 100 mA
1.2 mA/A at 45 Hz up to 5 kHz
from 100 mA to 1 A
5.4 mA/A at 45 Hz up to 5 kHz
above 1A to 10 A
5.4 mA/A at 45 Hz to 1 kHz
above 10 A to 20 A
1.6 mA/A from 45 Hz up to 1 kHz    
 
Resistance
7.8 mΩ/Ω from 1 Ω up to 100 Ω
71 µΩ/Ω above 100 Ω up to 100 kΩ
0.12 mΩ/Ω above 100 kΩ up to 1 MΩ
0.46 mΩ/Ω above 1 MΩ up to 10 MΩ
3.8 mΩ/Ω above 10 MΩ up to 100 MΩ
13 mΩ/Ω above 100 MΩ up to 1 GΩ

Multiple Turn Clamp on meters
DC Current
with Calibration and Measurement Capability of -
0.7% from 20 A to 1000 A
AC Current
0.7% from 20 A to 1000 A @ 50Hz
DC and low frequency electrical metrology - Electrical measurement and test equipment Appliance testers; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters AC voltage; DC voltage; Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
Continuity measurement -Resistance
0.10% from 0.5 Ω to 100 Ω  
Insulation resistance testers up to 2.5 kV
3.0% from 1 MΩ to 10 MΩ
3.2% from 10 MΩ to 1 GΩ
Insulation resistance testers from 2.5 kV to 10 kV
3.2% from 50 MΩ to 1 GΩ              
DC voltage
1.1 % from 1 kV to 10 kV
AC voltage(50Hz)
1.0% from 1 kV to 10 kV