National Association of Testing Authorities, Australia
Scope of Accreditation
Australian Calibration and Testing Services Pty Ltd
Site
Australian Calibration and Testing Services Pty Ltd
Accreditation No.
20882
Site No.
25073
Date of Accreditation
01 Dec 2022
Contact
Mr Dinesh Dewappriya P: +61 0433610404
Availability
Services available to external clients
Scope of Accreditation
Australian Calibration and Testing Services Pty Ltd
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical instrument calibrators | Instrument calibrators | AC current; AC voltage; DC current; DC voltage; Resistance | Direct measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration of Measurement Capability of -DC Voltage 94 μV/V from 50mV up to 100 mV 74 μV/V from 100mV up to 300 mV 57 μV/V from 300mV up to 10 V 62 μV/V from 10V up to 1000 V AC Voltage From 0.01 V to 0.03 V 2.3 mV/V at 50 Hz up to 10 kHz 5.3 mV/V from 10 kHz up to 100 kHz From 0.03 V to 0.10 V 0.8 mV/V at 50 Hz up to 10 kHz 5.3 mV/V from 10 kHz up to 100 kHz From 0.1 V to 1 V 0.78 mV/V at 50 Hz up to 10 kHz 5.3 mV/V from 10 kHz up to 100 kHz From 1 V to 100 V 0.71 mV/V at 50 Hz up to 10 kHz 5.4 mV/V from 10 kHz up to 100 kHz From 100 V to 1000 V 0.71 mV/V at 50 Hz up to 1 kHz 0.75 mV/V from 1 kHz up to 10 kHz DC Current 540 μA/A from 1 mA up to 100 mA 0.54 mA/A from 100 mA up to 1 A 2.1 mA/A from 1 A up to 10 A AC Current From 1mA to 100mA 3.5 mA/A at 50 Hz to 10 kHz above 100mA to 1A 2.2 mA/A at 50 Hz to 1 kHz above 1A to 10A 3.4 mA/A at 50 Hz to 1 kHz Resistance 0.23 mΩ/Ω from 100 Ω up to 1 kΩ 0.23 mΩ/Ω from 1 kΩ up to 10 kΩ 0.24 mΩ/Ω from 10 kΩ up to 100 kΩ 0.23 mΩ/Ω from 100 kΩ up to 1 MΩ 0.69 mΩ/Ω from 1 MΩ up to 10 MΩ 7.0 mΩ/Ω from 10 MΩ up to 100 MΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Current clamps; Digital multimeters (DMM); Ohm meters; Voltmeters | AC current; AC voltage; DC current; DC voltage; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -DC Voltage 104 μV/V from 50 mV up to 100 mV 71 μV/V from 100 mV up to 300 mV 50 μV/V from 300mV up to 300 V 44 μV/V from 300 V up to 1000 V AC Voltage From 0.01 V to 0.03 V 2.3 mV/V at 50 Hz up to 10 kHz 3.1 mV/V from 10 kHz up to 50 kHz 5.2 mV/V from 50 kHz up to 100 kHz From 0.03 V to 0.1 V 1.3 mV/V at 50 Hz up to 10 kHz 2.7 mV/V from 10 kHz up to 50 kHz 3.7 mV/V from 50 kHz up to 100 kHz above 0.1 V to 1 V 0.4 mV/V at 50 Hz up to 10 kHz 1.1 mV/V from 10 kHz up to 50 kHz 3.1 mV/V from 50 kHz up to 100 kHz above 1 V to 100 V 0.30 mV/V at 50 Hz up to 10 kHz 0.82 mV/V from 10 kHz up to 50 kHz 1.9 mV/V from 50 kHz up to 100 kHz above 100 V to 300 V 0.42 mV/V at 50 Hz up to 1 kHz 0.99 mV/V from 1 kHz up to 50 kHz 2.5 mV/V from 50 kHz up to 100 kHz above 300 V to 1000 V 0.43 mV/V at 50 Hz up to 1 kHz 0.73 mV/V from 1 kHz up to 10 kHz DC Current 140 μA/A from 1 mA up to 10 mA 97 μA/A from 10 mA up to 100 mA 0.33 mA/A from 100 mA up to 1 A 2.4 mA/A from 1 A up to 10 A AC Current From 1mA to 10mA 1.4mA/A at 45Hz up to 1 kHz 1.7 mA/A from 1 kHz up to 5 kHz above 10mA to 100mA 1.4 mA/A at 45 Hz up to 1 kHz 1.7 mA/A from 1 kHz up to 5 kHz above 100mA to 1A 4.7 mA/A at 45 Hz up to 1 kHz 5.4 mA/A from 1 kHz up to 5 kHz above 1A to 10A 4.7 mA/A at 45Hz to 1 kHz Resistance 71 µΩ/Ω from 100 Ω up to 100 kΩ 120 µΩ/Ω from 100 kΩ up to 1 MΩ 0.46 mΩ/Ω from 1 MΩ up to 10 MΩ 3.8 mΩ/Ω from 10 MΩ up to 100 MΩ Multiple Turn Clamp on meters DC Current with Calibration and Measurement Capability of - 0.7% from 20 A to 100 0A AC Current 0.7% from 20 A to 1000 A @ 50Hz |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20882
Site No.
25073
Print date
24 Nov 2024
END OF SCOPE