National Association of Testing Authorities, Australia
Scope of Accreditation
Department of Defence Air Warfare Centre - AWE SQN Electromagnetic Test Facility
Scope of Accreditation
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Assessment of emissions and immunity - EMC emission standards | Electrical and electronic products; Power leads; Radio equipment | Conducted interference | Not applicable |
MIL-STD-461 (Revisions D, E, F & G) by the methods of- CE 101, CE 102, CE 106 |
CE 101: 30 Hz to 10 kHz; CE 102: 10 kHz to 10 MHz; CE 106: 10 kHz to 40 GHz |
Radiated interference | Not applicable |
MIL-STD-461 (Revisions D, E, F & G) by the methods of- RE 101, RE 102, RE 103 |
RE 101: Magnetic field 30 Hz to 100 kHz; RE 102: Electric field @ 1 meter, 10 kHz to 18 GHz; RE 103: Electric field @ 1m, 10 kHz to 40 GHz |
||
Assessment of emissions and immunity - EMC immunity standards | Electrical and electronic products; Power leads; Radio equipment | Radiated susceptibility | Electric field; Magnetic field |
MIL-STD-461 (Revisions D, E, F & G) by the methods of- RS 101, RS 103 |
RS 101 Magnetic field 30 Hz to 150 kHz; RS 103 Electric field 10 kHz to 40 GHz |
Conducted susceptibility | Bulk cable injection; Damped sinusoidal transients; Impulse excitation |
MIL-STD-461 (Revisions D, E, F & G) by the methods of- CS 101, CS 114, CS 115, CS 116 |
CS 101: 30 Hz to 150 kHz; CS 114: 10 kHz to 400 MHz; CS 116: 10 kHz to 100 MHz |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
15516
Site No.
16470
Print date
14 Aug 2022