Azuma Design Pty Limited

Site

Azuma Test Facility

Accreditation No.

15147

Site No.

15690

Date of Accreditation

04 Nov 2005

Address

38 Redfern Street
Wetherill Park, NSW 2164
Australia

azumadesign.com.au

Contact

Mr Ash Horne P: +61 (02) 96040255

Availability

Services available to external clients

Scope of Accreditation

Azuma Test Facility

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Evaluation of access protection products Edge protection (including guardrails and guardrail posts) Dynamic load; Static load Not applicable

AS/NZS 4994.1 Section 4 Appendix A-E

Including testing of Temporary edge protection
Edge protection (including guardrails and guardrail posts) Load Not applicable

 AS 1657 Appendix B, C & E

Fencing and gates designed for fixed installation Closing and latching performance; Durability; Rigidity; Strength Not applicable

AS 1926.1 Sections 3.1, 3.2, 3.3, 3.3.2, 3.4, 3.5, 3.6, Appendices A, B, C, D, E, F

Including testing of Safety barriers and gate units for swimming pools
Locksets for windows and doors Durability; Durability of mechanism; Ease of operation; Keying security; Physical security - Strength; Strength of return mechanism Not applicable

AS 4145.1; AS 4145.2; AS 4145.3; AS 4145.4; AS 4145.5; EN 1906

excluding salt spray tests

For AS 4145.4 exclude clause 3.1.4 (Corrosion resistance)
Mechanical performance evaluation of components for building envelopes, framing and interior lining Door, window and skylight assemblies Air infiltration; Deflection; Operating force; Strength; Water penetration resistance Not applicable

 AS 2047,AS 4420 Part 1; NZS 4211; AWA ICP 003(excluding Appendices E and F)

Including testing of Aluminium and timber windows
Impact resistance; Knife resistance; Pull-out resistance; Resistance to attack using a shearing device; Resistance to lever forces - Jemmy Not applicable

AS 5039, AS 5041, and ICP002 section 3,

Queensland Government Department of Public Works - Design guidelines for Queensland Public Cyclone Shelters - Appendix I

Including testing of security Screens (hinged and sliding) and security window grilles
Door, window and skylight assemblies Protection of openable windows by falls Not applicable

AS 5203

Including testing of Rollers
General purpose glazing products Strength at ultimate limit state loading Not applicable AS 1288 Appendix H & I
Insulating glass units Moisture penetration index Calculation I.S. EN 1279-2
Polymeric matrix incorporating desiccant Moisture content Gravimetry I.S. EN 1279-4 Annex G
Moisture content Karl-Fischer titration I.S. EN 1279-4 Annex F
Roof, floor and wall framing assemblies Load; Pressure; Resistance to static pressure Not applicable AS 4040.0; AS 4040.1; AS 4040.2; AS 4040.3
Mechanical performance evaluation of ladders, racks, scaffolds and supports Ladders Bending properties; Deflection; Load carrying capacity; Strength Not applicable

AS 1892.1; AS 1892.2

excluding tests on labels and electrical properties

Including testing of Portable ladders
Including testing for Performance and dimensional tests
Scaffolding and scaffolding components Bending properties; Deflection; Load carrying capacity; Strength Not applicable

 AS/NZS 1577

ISO/IEC 17025 (2017)

Materials

Service Product Determinant Technique Procedure Limitations
Material performance evaluation of absorbents Desiccants Available water adsorption capacity (AWAC) Gravimetry I.S. EN 1279-4 Annex E2
Loss on ignition Gravimetry I.S. EN 1279-4 Annex E1

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.