National Association of Testing Authorities, Australia
Scope of Accreditation
Certex Lifting
Site
Bibra Lake Testing
Accreditation No.
15097
Site No.
18291
Date of Accreditation
11 Jun 2009
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of load generating lifting appliances | Cranes | Proof load | Not applicable | AS 1418.1; AS 1418.2; AS 1418.3 clause 12.2.4(a); AS 1418.5 clauses 11.5, 11.6, 11.7, 11.8; AS 1418.17; In-house procedure TRSMNLWI043 | 1 kN to 5000 kN |
Serial and lever hoists | Breaking load; Proof load | Not applicable | AS 1418.2, AS 3777, AS 4991, in-house test method TRSMNLWI035 | Proof load in the range 0.8 kN to 2000 kN Breaking load in the range 4 kN to 1200 kN | |
Evaluation of load handling, rigging and tensioning systems | Anchorages and supports for industrial fall arrest systems | Proof load | Not applicable | in-house test method TRSMNLWI019 | |
Chain | Breaking load; Proof load | Not applicable | AS 2321 | Proof load in the range 0.8 kN to 2000 kN including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN | |
Chain slings | Breaking load; Proof load | Not applicable | AS 3775 | Proof load in the range 0.8 kN to 2000 kN including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN | |
Eye bolts; Plate clamps and gripping devices; Rigging screws and turnbuckles; Shackles; Sheave blocks; Swivels | Breaking load; Proof load | Not applicable | AS 2089, AS 2317, AS 2318, AS 2319, AS 2741, AS 3776, AS 4991, Marine Orders Part 32 | Proof load in the range 0.8 kN to 2000 kN including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN | |
Lifting clutches for concrete elements | Proof load | Not applicable | AS 3850.1 | Proof load in the range 0.8 kN to 2000 kN | |
Lifting components for chain slings; Lifting tynes and attachments | Breaking load; Proof load | Not applicable | AS 4991 | Proof load in the range 0.8 kN to 2000 kN Breaking load in the range 4 kN to 1200 kN | |
Synthetic fibre roundslings | Breaking load; Proof load | Not applicable | AS 4497.1 (1997), AS 4497 | Proof load in the range 0.8 kN to 2000 kN Including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN | |
Synthetic webbing flat slings | Breaking load; Proof load | Not applicable | AS 1353.1 | Proof load in the range 0.8 kN to 2000 kN Including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN | |
Wire rope slings | Breaking load; Proof load | Not applicable | AS 1666.1 | Proof load in the range 0.8 kN to 2000 kN including on-site tests up to 1920 kN Breaking load in the range 4 kN to 1200 kN |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
15097
Site No.
18291
Print date
26 Dec 2024