ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Establishment of annex facilities | Materials defined by all or some for which the site is accredited | Determinations defined by all or some for which the site is accredited | Techniques defined by all or some for which the site is accredited | ||
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar consistence in situ | Concrete, grout and mortar | Slump flow | Cone; J-ring; T500 | AS 1012.3.1; AS1012.3.5 | |
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar permeability | Concrete, grout and mortar | Permeability | Volume change with water absorption - Permeable voids | AS 1012.21 | |
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar properties | Concrete, grout and mortar | Fibre content in fresh concrete | Not applicable | AS 1012.25.1 | |
Flexural strength | Modulus of rupture | AS 1012.11 | |||
Indirect tensile strength | Brazil | AS 1012.10 | |||
Compressive strength | Core; Cylinder | AS 1012.9, AS 1012.14 | |||
Air content of freshly mixed concrete; Mass per unit volume - Fresh concrete | In situ measurement using fixed volume measure | AS 1012.5 | |||
Mass per unit volume - Hardened concrete | Dimensions | AS 1012.12.1 | |||
Air content of freshly mixed concrete | Reduced air pressure | AS 1012.4.2 | |||
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar shrinkage | Concrete, grout and mortar | Drying shrinkage specimen measurement | Not applicable | AS 1012.13 | |
Evaluation of geotechnical and civil construction material - Concrete, grout and mortar specimen manufacture and curing | Concrete, grout and mortar | Specimen conditioning; Specimen manufacture; Specimen manufacture and curing | Curing cylinder specimens in the laboratory; Curing grout and mortar cube specimens in the laboratory; Dry conditioning of hardened concrete core specimens; In situ manufacture and curing of cylindrical specimens; In situ manufacture and curing of flexural strength specimens; Manufacture and curing of cylindrical specimens in the laboratory; Manufacture and curing of drying shrinkage specimens in the laboratory; Manufacture and curing of flexural strength specimens in the laboratory; Mixing concrete in the laboratory; Wet conditioning of hardened concrete core specimens | AS 1012.8.1, AS 1012.8.2, AS 1012.8.3, AS 1012.8.4, AS 1012.14 | |
Sample collection | Concrete, grout and mortar | Not applicable | Fresh concrete from a mixer | AS 1012.1 |
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Annex facility | Materials defined by all or some for which the site is accredited | Determinations defined by all or some for which the site is accredited | Techniques defined by all or some for which the site is accredited | The Bulleen Annex Facility, Site No 26862 is established from 26 August 2024 until 31 January 2030 for SPARK NEL DC JV in relation to NORTH EAST LINK - PRIMARY PACKAGE, Contract Nos. 6400042465, 6400042466, 6400042467, 6400042468, 6400042469, 6400042470, 6400042471, 6400042472, 6400042473, 6400042474. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.