National Association of Testing Authorities, Australia
Scope of Accreditation
C-PRAV Labs Pty Ltd
Site
C-PRAV Labs Pty Ltd
Accreditation No.
21372
Site No.
25752
Date of Accreditation
17 Jul 2024
Contact
Availability
Services available to external clients
Scope of Accreditation
C-PRAV Labs Pty Ltd
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electrical equipment approval and safety evaluation | Audio, video and similar electronic equipment | Electrical safety | Not applicable | AS/NZS 62368.1 IEC/EN 62368-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Touch current test Capacitor discharge test Ball pressure test Abnormal / single fault test Mechanical strength test Dielectric Strength test |
Electrical appliances, coupling devices and accessories | Electrical safety | Not applicable | AS/NZS 60335.1 IEC/EN 60335-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Leakage current test Ball pressure test Abnormal test Mechanical strength test Dielectric Strength test | |
Laboratory and electromedical equipment | Electrical safety | Not applicable | AS 61010-1 IEC/EN 61010-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Touch current test Capacitor discharge test Ball pressure test Abnormal / single faut test Mechanical strength test Dielectric Strength test | |
Electromagnetic compatibility (EMC) - Emissions - Commercial | Adjustable speed electrical power drive systems | Conducted emissions; Radiated emissions | Not applicable | IEC 61800-3; EN 61800-3; AS 61800.3 | |
Audio, video, audio-visual and entertainment lighting control apparatus for professional use | Conducted emissions; Radiated emissions | Not applicable | EN 55103-1 | ||
Electrical and electronic products | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000-3-2; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000-3-3; IEC 61000-3-3; EN 61000-3-3; CISPR 16-2-3; CISPR 16-2-1; | ||
Electrical and electronic products; Power tools - Electric | Conducted emissions; Discontinuous disturbances; Radiated emissions | Not applicable | AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; | ||
Electrical equipment for measurement, control and laboratory use | Conducted emissions; Radiated emissions | Not applicable | IEC 61326-1; EN 61326-1; IEC 61326-2-6; EN 61326-2-6; | ||
Electrical lighting and similar equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 15; CISPR 15; EN 55015 | ||
Electrically powered wheelchairs and motorised scooters | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 3696.21 | ||
Industrial environments | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000.6.4; IEC 61000-6-4; EN 61000-6-4 | ||
Industrial, scientific and medical (ISM) radio-frequency equipment | Conducted emissions; Radiated emissions | Not applicable | AS CISPR 11 ; CISPR 11; EN 55011; | ||
Maritime navigation equipment | Conducted emissions; Radiated emissions | Not applicable | EN 60945; IEC 60945; IEC 60092-504; IACS UR E10; DNVGL-CG-0339 | ||
Medical electrical equipment | Conducted emissions; Radiated emissions | Not applicable | AS IEC 60601.1.2; AS/NZS 3200.1.2; EN 60601-1-2; IEC 60601-1-2 | ||
Multimedia equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 32; CISPR 32; EN 55032; | ||
Radio equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 300 328 v2.2.2; ETSI EN 300 328; ETSI EN 301 893 v2.1.1; ETSI EN 301 893; ETSI EN 302502 v2.1.1; ETSI EN 302 502; ETSI EN 301 908-1/-2/-13; ETSI EN 300 220-1 v3.1.1; ETSI EN 300 220-1; ETSI EN 300 220-2 v3.2.1; ETSI EN 300 220-2; ETSI EN 300 330 v2.1.1; ETSI EN 300 330; ETSI EN 30 440v2.1.1; ETSI EN 330 440 | Bluetooth (BDR/EDR,BLE) Wi-Fi (2.4Ghz) Wi-Fi (5.2Ghz,5.8Ghz) SRD operating at 25Mhz to 1GHz SRD operating at 9kHz to 30Mhz LTE | |
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted emissions; Radiated emissions | Not applicable | EN 50121-3-1; EN 50121-3-2; EN 50155; EN 50121-4; EN 50121-5 | ||
Residential, commercial and light industrial environments | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000.6.3; IEC 61000-6-3; EN 61000-6-3; | ||
Road traffic signal systems and devices | Conducted emissions; Radiated emissions | Not applicable | EN 50293 | ||
Telecommunication network equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 301 489-1/17/3/52/19 ; ETSI EN 300 386; | ||
Electromagnetic compatibility (EMC) - Immunity - Commercial | Components of fire, intruder and social alarm systems | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50130-4 | |
Electrical and electronic products | Voltage short dips and interruptions | Not applicable | AS/NZS 61000.4.11(2005); AS/NZS 61000.4.11; IEC 61000-4-11(2020); IEC 61000-4-11; EN 61000-4-11 (2020); EN 61000-4-11; | ||
Conducted susceptibility; Induced signal susceptibility | Not applicable | AS/NZS 61000.4.6 (2017); AS/NZS 61000.4.6; IEC 61000-4-6 (2013); IEC 61000-4-6; EN 61000-4-6 (2014); EN 61000-4-6; | |||
Power frequency magnetic field | Not applicable | AS/NZS 61000.4.8 (2012); AS/NZS 61000.4.8; IEC 61000-4-8 (2009); IEC 61000-4-8 EN 61000-4-8 (2013); EN 61000.4.8 | |||
Surge immunity | Not applicable | AS/NZS 61000.4.5 (2014); AS/NZS 61000.4.5; IEC 61000-4-5 (2014); IEC 61000-4-5; EN 61000-4-5 (2014); EN 61000-4-5; | |||
Electrostatic discharge | Not applicable | AS/NZS 61000.4.2 (2013); AS/NZS 61000.4.2 EN 61000-4-2 (2009); EN 61000-4-2 IEC 61000-4-2 (2008); IEC 6100-4-2 | |||
Electrical fast transient | Not applicable | AS/NZS 61000.4.4 (2013); AS/NZS 61000.4.4; IEC 61000-4-4 (2012); IEC 61000-4-4; EN 61000-4-4 (2012); EN 61000-4-4 | |||
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS 61800.3 EN 61800-3; IEC 61800-3; | |||
Electrical and electronic products; Power tools - Electric | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZE CISPR 14.2; CISPR 14-2; EN 55014-2 | ||
Electrical equipment for measurement, control and laboratory use | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 61326-1; IEC 61326-1; EN 61326-2-6; IEC 61326-2-6 | ||
Electrical lighting and similar equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61547; IEC 61547 | ||
Industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000.6.2 | ||
Maritime navigation equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | IEC 60092-504; EN 60945; IEC 60945, IACS UR E10; DNVGL-CG-0339; | ||
Medical electrical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS IEC 60601.1.2; EN 60601-1-2; IEC 60601-1-2 | ||
Multimedia equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS CISPR 35; CISPR 35; EN 55035 | ||
Radio equipment; Telecommunication network equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | ETSI EN 301 489-1/3/17/52/19; ETSI EN 300 386; | ||
Railway electronic equipment used on rolling stock; Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50121-3-1; EN 50121-3-2; EN 50155; EN 50121-4; EN 50121-5 | ||
Residential, commercial and light industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS 61000.6.1; IEC 61000-6-1; EN 61000-6-1 | ||
Electromagnetic radiation exposure - Radiofrequency (RF) fields | Hand held and wireless communication devices | RF exposure assessment - Power flux density | Calculation | ARPANSA RPS S-1; AS/NZS 2772.2 2016; ICNIRP Guidelines: 2020; EN 62311 EN 62479 | Products with radio module (Normally used more than 20 centimetres from the human body) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21372
Site No.
25752
Print date
23 Nov 2024
END OF SCOPE