National Association of Testing Authorities, Australia
Scope of Accreditation
C-PRAV Labs Pty Ltd
Site
C-PRAV Labs Pty Ltd
Accreditation No.
21372
Site No.
25752
Date of Accreditation
17 Jul 2024
Contact
Availability
Services available to external clients
Scope of Accreditation
C-PRAV Labs Pty Ltd
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electrical equipment approval and safety evaluation | Audio, video and similar electronic equipment | Electrical safety | Not applicable | AS/NZS 62368.1 IEC/EN 62368-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Touch current test Capacitor discharge test Ball pressure test Abnormal / single fault test Mechanical strength test Dielectric Strength test |
Electrical appliances, coupling devices and accessories | Electrical safety | Not applicable | AS/NZS 60335.1 IEC/EN 60335-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Leakage current test Ball pressure test Abnormal test Mechanical strength test Dielectric Strength test | |
Laboratory and electromedical equipment | Electrical safety | Not applicable | AS 61010-1 IEC/EN 61010-1 | Limitations Only the following tests are applicable Input test Temperature rise test Earthing resistance test Touch current test Capacitor discharge test Ball pressure test Abnormal / single faut test Mechanical strength test Dielectric Strength test | |
Electromagnetic compatibility (EMC) - Emissions - Commercial | Adjustable speed electrical power drive systems | Conducted emissions; Radiated emissions | Not applicable | IEC 61800-3; EN 61800-3; AS 61800.3 | |
Audio, video, audio-visual and entertainment lighting control apparatus for professional use | Conducted emissions; Radiated emissions | Not applicable | EN 55103-1 | ||
Electrical and electronic products | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000-3-2; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000-3-3; IEC 61000-3-3; EN 61000-3-3; CISPR 16-2-3; CISPR 16-2-1; | ||
Electrical and electronic products; Power tools - Electric | Conducted emissions; Discontinuous disturbances; Radiated emissions | Not applicable | AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; | ||
Electrical equipment for measurement, control and laboratory use | Conducted emissions; Radiated emissions | Not applicable | IEC 61326-1; EN 61326-1; IEC 61326-2-6; EN 61326-2-6; | ||
Electrical lighting and similar equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 15; CISPR 15; EN 55015 | ||
Electrically powered wheelchairs and motorized scooters | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 3696.21 | ||
Industrial environments | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000.6.4; IEC 61000-6-4; EN 61000-6-4 | ||
Industrial, scientific and medical (ISM) radio-frequency equipment | Conducted emissions; Radiated emissions | Not applicable | AS CISPR 11 ; CISPR 11; EN 55011; | ||
Maritime navigation equipment | Conducted emissions; Radiated emissions | Not applicable | EN 60945; IEC 60945; IEC 60092-504; IACS UR E10; DNVGL-CG-0339 | ||
Medical electrical equipment | Conducted emissions; Radiated emissions | Not applicable | AS IEC 60601.1.2; AS/NZS 3200.1.2; EN 60601-1-2; IEC 60601-1-2 | ||
Multimedia equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 32; CISPR 32; EN 55032; | ||
Radio equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 300 328 v2.2.2; ETSI EN 300 328; ETSI EN 301 893 v2.1.1; ETSI EN 301 893; ETSI EN 302502 v2.1.1; ETSI EN 302 502; ETSI EN 301 908-1/-2/-13; ETSI EN 300 220-1 v3.1.1; ETSI EN 300 220-1; ETSI EN 300 220-2 v3.2.1; ETSI EN 300 220-2; ETSI EN 300 330 v2.1.1; ETSI EN 300 330; ETSI EN 30 440v2.1.1; ETSI EN 330 440 | Bluetooth (BDR/EDR,BLE) Wi-Fi (2.4Ghz) Wi-Fi (5.2Ghz,5.8Ghz) SRD operating at 25Mhz to 1GHz SRD operating at 9kHz to 30Mhz LTE | |
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted emissions; Radiated emissions | Not applicable | EN 50121-3-1; EN 50121-3-2; EN 50155; EN 50121-4; EN 50121-5 | ||
Residential, commercial and light industrial environments | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 61000.6.3; IEC 61000-6-3; EN 61000-6-3; | ||
Road traffic signal systems and devices | Conducted emissions; Radiated emissions | Not applicable | EN 50293 | ||
Telecommunication network equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 301 489-1/17/3/52/19 ; ETSI EN 300 386; | ||
Electromagnetic compatibility (EMC) - Immunity - Commercial | Components of fire, intruder and social alarm systems | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50130-4 | |
Electrical and electronic products | Voltage short dips and interruptions | Not applicable | AS/NZS 61000.4.11(2005); AS/NZS 61000.4.11; IEC 61000-4-11(2020); IEC 61000-4-11; EN 61000-4-11 (2020); EN 61000-4-11; | ||
Conducted susceptibility; Induced signal susceptibility | Not applicable | AS/NZS 61000.4.6 (2017); AS/NZS 61000.4.6; IEC 61000-4-6 (2013); IEC 61000-4-6; EN 61000-4-6 (2014); EN 61000-4-6; | |||
Power frequency magnetic field | Not applicable | AS/NZS 61000.4.8 (2012); AS/NZS 61000.4.8; IEC 61000-4-8 (2009); IEC 61000-4-8 EN 61000-4-8 (2013); EN 61000.4.8 | |||
Surge immunity | Not applicable | AS/NZS 61000.4.5 (2014); AS/NZS 61000.4.5; IEC 61000-4-5 (2014); IEC 61000-4-5; EN 61000-4-5 (2014); EN 61000-4-5; | |||
Electrostatic discharge | Not applicable | AS/NZS 61000.4.2 (2013); AS/NZS 61000.4.2 EN 61000-4-2 (2009); EN 61000-4-2 IEC 61000-4-2 (2008); IEC 6100-4-2 | |||
Electrical fast transient | Not applicable | AS/NZS 61000.4.4 (2013); AS/NZS 61000.4.4; IEC 61000-4-4 (2012); IEC 61000-4-4; EN 61000-4-4 (2012); EN 61000-4-4 | |||
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS 61800.3 EN 61800-3; IEC 61800-3; | |||
Electrical and electronic products; Power tools - Electric | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZE CISPR 14.2; CISPR 14-2; EN 55014-2 | ||
Electrical equipment for measurement, control and laboratory use | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 61326-1; IEC 61326-1; EN 61326-2-6; IEC 61326-2-6 | ||
Electrical lighting and similar equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61547; IEC 61547 | ||
Industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000.6.2 | ||
Maritime navigation equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | IEC 60092-504; EN 60945; IEC 60945, IACS UR E10; DNVGL-CG-0339; | ||
Medical electrical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS IEC 60601.1.2; EN 60601-1-2; IEC 60601-1-2 | ||
Multimedia equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS CISPR 35; CISPR 35; EN 55035 | ||
Radio equipment; Telecommunication network equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | ETSI EN 301 489-1/3/17/52/19; ETSI EN 300 386; | ||
Railway electronic equipment used on rolling stock; Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50121-3-1; EN 50121-3-2; EN 50155; EN 50121-4; EN 50121-5 | ||
Residential, commercial and light industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS 61000.6.1; IEC 61000-6-1; EN 61000-6-1 | ||
Electromagnetic radiation exposure - Radiofrequency (RF) fields | Hand held and wireless communication devices | RF exposure assessment - Power flux density | Calculation | ARPANSA RPS S-1; AS/NZS 2772.2 2016; ICNIRP Guidelines: 2020; EN 62311 EN 62479 | Products with radio module (Normally used more than 20 centimetres from the human body) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21372
Site No.
25752
Print date
04 Oct 2024