National Association of Testing Authorities, Australia
Scope of Accreditation
Gawler Instrument Company
Site
Calibration Lab
Accreditation No.
20254
Site No.
24104
Date of Accreditation
20 Dec 2017
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Manometers; Mechanical pressure gauges | Gauge pressure | Comparison with dead weight tester; Comparison with reference instrument | Using MSA Test Method 2-2022 Using MSA Test Method 1-2008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrations with Calibration and Measurement Capability of- 0.005 kPa or 0.017% of reading (whichever is greater) from 10 kPa to 4000 kPa 0.5 kPa or 0.017 % of reading (whichever is greater) above 4000 kPa to 100 MPaOn-site calibration 0.13 kPa from -95 kPa to -4 kPa and above 4 kPa to 100 kPa 1.5 Pa or 0.09% of reading (whichever is greater) above -4 kPa to 4 kPa 1.4 kPa or 0.1% of reading (whichever is greater) above 100 kPa to 100 MPa Temperature range for on-site calibrations 10 °C to 30 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure standards | Pressure calibrators - Non-dead weight | Gauge pressure | Comparison with reference instrument | Using MSA Test Method 1-2008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of0.005 kPa or 0.017% of reading (whichever is greater) from 10 kPa to 4000 kPa 0.5 kPa or 0.017 % of reading (whichever is greater) above 4000 kPa to 100 MPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipmentincluding on-site calibrations | Digital temperature measuring systems | Temperature | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of-0.07 ºC at 0 ºC 0.10 ºC from -25 ºC to 150 ºC On-site calibration 0.19 ºC from -25 ºC to 150 ºC |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20254
Site No.
24104
Print date
21 Nov 2024