National Association of Testing Authorities, Australia
Scope of Accreditation
National Measurement Institute - Chemical and Biological Services
Site
Chemical Reference Values
Accreditation No.
198
Site No.
20844
Date of Accreditation
11 Apr 2012
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Agribusiness
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Agricultural certified reference materials | Stockfeeds | Agricultural chemicals; Antibiotics; Pesticides; Trace elements; Veterinary chemicals; Vitamins | ICP-MS - Standard addition; Isotope dilution GC-MS; Isotope dilution GC-MS-MS; Isotope dilution ICP-MS; Isotope dilution LC-MS-MS | Reference Materials Producers Quality Manual | Organic compounds withing the molecular weight range of 70 to 800 g/mol Inorganic compounds within the molecular weight range of 6 to 238 g/mol | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With property value capability of -Minimum concentration of 0.001 mg/kg Range of uncertainty of measurement of 1% to 15% relative Supported by CIPM Key Comparisons CCQM-K5; CCQM-K24; CCQM-K30; CCQM-K43; CCQM-K56; CCQM-K60; CCQM-K81; CCQM-K89; CCQM-K95; CCQM-K100; CCQM-K108; CCQM-K125; CCQM-K141; CCQM-K145 Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS GC-MS-MS; LC-MS-MS and ICP-MS or Standard addition ICP-MS. This includes but is not limited to Agricultural chemicals; Antibiotics; Pesticides; Veterinary chemicals; Vitamins; Trace elements |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Animal Health
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pathology certified reference materials | Blood; Blood products; Urine | Clinical markers and metabolites; Hormones; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids; Steroids and metabolites; Trace elements | Density meter; ICP-MS - Standard addition; Isotope dilution GC-MS-MS; Isotope dilution ICP-MS; Isotope ratio mass spectrometry (IRMS) | Reference Materials Producers Quality Manual | Isotope dilution mass spectrometery and standard addition: Organic compounds within the molecular weight range of 70 to 800 g/mol Inorganic compounds within the molecular weight range of 6 to 238 g/mol Isotope ratio mass spectrometry: Organic compounds combustible at temperatures up to 950ºC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Carbon isotope ratio values (δ13CVPDB/%) -10 to -32 for compounds amenable to Isotope ratio MS with an uncertainty of measurement range of 0.10 to 2.00 Minimum concentration of 0.0001 mg/kg for compounds that are amenable to Isotope dilution mass spectrometry using GC-MS GC-MS-MS, ICP-MS or Standard addition ICP-MS with a relative uncertainty of measurement of 1% to 15% Supported by CIPM Key Comparisons CCQM-K63; CCQM-K69; CCQM-K81; CCQM-K109; CCQM-K132; CCQM-K139; CCQM-K140 and CCQM-K141 Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS GC-MS-MS LC-MS and ICP-MS; Standard Addition ICP-MS and Isotope ratio mass spectrometry. This includes but is not limited to Clinical markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids and metabolites and Trace elements |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pure organic certified reference materials | Sport doping control references | Environmental markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Synthetic cannabinoids; Synthetic steroids and metabolites | Isotope dilution GC-MS; Isotope dilution GC-MS-MS; Isotope dilution LC-MS-MS | Reference Materials Producers Quality Manual | Pure organic compounds in solution within the molecular weight range of 70 to 800 g/mol | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Minimum concentration of 0.01 mg/kg Range of relative measurement uncertainty of 2 - 6% Supported by CIPM Key Comparisons CCQM-K63, CCQM-K69 and CCQM-K132 Covers compounds in solution that are amenable to isotope dilution mass spectrometry using GC-MS, GC-MS-MS and LC-MS-MS. This includes but is not limited to Environmental markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites and Steroids and metabolites | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environmental markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids and metabolites; Synthetic steroids and metabolites | Elemental analysis - Isotope ratio mass spectrometry (EA-IRMS); Gas chromatography - Combustion - Isotope ratio mass spectrometry (GC-C-IRMS) | Reference Materials Producers Quality Manual | Organic compounds combustible at temperatures up to 950ºC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Carbon isotope ratio values (δ13CVPDB/%) -10 to -32 Range of uncertainty of measurement of 0.10 to 2.00 Supported by CIPM Key Comparison CCQM-K140 Covers compounds that are amenable to Combustion isotope ratio mass spectrometry. This includes but is not limited to Environmental markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids and metabolites |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Environment
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Certified reference materials for chemical composition, residues and contaminants | Sediments; Soils | Agricultural chemicals; Hydrocarbons; Pesticides; Polyhalogenated biphenyls; Trace elements | ICP-MS - Standard addition; Isotope dilution GC-MS; Isotope dilution GC-MS-MS; Isotope dilution ICP-MS; Isotope dilution LC-MS-MS | Reference Materials Producers Quality Manual | Organic compounds in the molecular weight range of 70 to 800 g/mol Inorganic compounds in the molecular weight range of 6 to 238 g/mol | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Minimum conentration of 0.001 mg/kg Range of measurement uncertainty of 3 - 20% Supported by CIPM Key Comparisons CCQM-K13; CCQM-K25, CCQM-K28 and CCQM-K102 Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS; GC-MS-MS; LC-MS-MS and ICP-MS and Standard addition ICP-MS. This includes but is not limited to Agricultural chemicals; Hydrocarbons; Pesticides; Polyhalogenated biphenyls and Trace elements | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Waters | Agricultural chemicals; Per- and polyfluoroalkyl substances (PFAS); Pesticides; Trace elements | Density meter; ICP-MS - Standard addition; Isotope dilution GC-MS; Isotope dilution ICP-MS; Isotope dilution LC-MS-MS | Reference Materials Producers Quality Manual | Organic contaminants in the molecular weight range of 70 to 800 g/mol Inorganic compounds in the molecular weight range of 6 to 238 g/mol | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Minimum concentration of 0.00005 mg/kg Range of measurement uncertainty of 0.3 to 20% relative Supported by CIPM Key Comparisions CCQM-K70; CCQM-K87 and CCQM-K124 Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS; GC-MS-MS; LC-MS-MS and ICP-MS and Standard addition ICP-MS. This includes but is not limited to Agricultural chemicals; Pesticides; Per- and polyfluroalkyl substances (PFAS); and Trace elements |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Food and Beverage
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Food certified reference materials | Foods; Potable waters | Agricultural chemicals; Antibiotics; Per- and polyfluoroalkyl substances (PFAS); Pesticides; Trace elements; Veterinary chemicals; Vitamins | Density meter; ICP-MS - Standard addition; Isotope dilution GC-MS; Isotope dilution GC-MS-MS; Isotope dilution ICP-MS; Isotope dilution LC-MS-MS | Reference Materials Producers Quality Manual | Organic compounds within the molecular weight range of 70 to 800 g/mol Inorganic compounds within the molecular weight range of 6 to 238 g/mol | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Minimum concentration of 0.00005 mg/kg With a measurement uncertainty of 0.35 to 15% relative Supported by CIPM Key Comparisons CCQM-K5; CCQM-K24; CCQM-K30; CCQM-K43; CCQM-K56; CCQM-K60; CCQM-K81; CCQM-K89; CCQM-K95; CCQM-K100; CCQM-K108; CCQM-K125; CCQM-K141; CCQM-K145; Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS; GC-MS-MS; LC-MS-MS or ICP-MS; Standard addition ICP-MS. This includes but is not limited to Agricultural chemicals; Antibiotics; Pesticides; Per- and polyfluroalkyl substances (PFAS); Veterinary chemicals; Vitamins; Trace elements |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Human Pathology
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pathology certified reference materials | Blood; Blood products; Urine | Clinical markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids; Steroids and metabolites; Trace elements | Density meter; ICP-MS - Standard addition; Isotope dilution GC-MS-MS; Isotope dilution ICP-MS; Isotope dilution LC-MS-MS; Isotope ratio mass spectrometry (IRMS) | Reference Materials Producers Quality Manual | Isotope dilution mas spectrometry and standard addition: Organic compounds within the molecular weight range of 70 to 800 g/mol Inorganic compounds within the molecular weight range of 6 to 238 g/mol Isotope ratio mass spectrometry: Organic compounds combustible at temperatures up to 950ºC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Carbon isotope ratio values (δ13CVPDB/%) -10 to -32 for compounds amenable to Isotope ratio MS with an uncertainty range of 0.10 to 2.00 Minimum concentration of 0.001 mg/kg for compounds that are amenable to Isotope dilution mass spectrometry using GC-MS and LC-MS with relative uncertainty of measurement of 1% to 15% Minimum concentration of 0.001 mg/kg for compounds that are amenable to Isotope dilution mass spectrometry and standard addition using ICP-MS with relative uncertainty of measurement of 1% to 15% Supported by CIPM Key Comparisons CCQM-K63; CCQM-K69; CCQM-K81; CCQM-K109; CCQM-K132; CCQM-K139; CCQM-K140 CCQM-K141 Covers compounds that are amenable to Isotope dilution mass spectrometry using GC-MS, GC-MS-MS LC-MS and ICP-MS, Standard addition using ICP-MS and Isotope ratio mass spectrometry. This includes but is not limited to Clinical markers and metabolites; Hormones and metabolites; Pharmaceutical drugs and metabolites; Steroids and metabolites and Trace elements |
ISO 17034 (2016)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Legal
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Forensic certified reference materials | Ethanol reference standards | Aqueous ethanol standard | Density meter; Isotope dilution GC-MS; Isotope dilution GC-MS-MS | Reference Materials Producers Quality Manual | Minimum concentration of 0.6 g/kg | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With a property value capability of -Minimum concentration of 0.6 g/kg Range of uncertainty of measurement of 0.5% to 2% relative Supported by CCQM-K27 and CCQM-K79 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
198
Site No.
20844
Print date
26 Dec 2024