Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Dynamic gas blenders | Dynamic gas blenders | Mass flow | Absolute method | in-house method CAL-001 | 5 to 200 cm3/min (at STP) and 500 to 10,000 cm3/min (at STP) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of gas diluters (mass flow controllers) by in-house method CAL-001 in the ranges 5 to 200 cm3/min (at STP) and 500 to 10,000 cm3/min (at STP) with calibration and measurement capability of - 0.3 % of full scale | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chemical metrology - Gas analysers | Gas analysers | Concentration | Direct measurement by certified reference material | AS 3580 6.1 and in-house methods CAL 004 | 20 ppb to 520 ppb (nmol/mol and part per 109). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With calibration and measurement capability of- 1.4 ppb + 0.4 % of the reading in the range of 20 ppb to 520 ppb (nmol/mol (part per 109).for ozone | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow metrology - Flow measuring devices and systems | Orifice meters | Flow rate | Direct measurement by critical flow venturi nozzle | in-house methods CAL-002 and CAL-006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with calibration and measurement capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow metrology - Environmental flow measuring devices and systems | Air sampling pumps and meters | Flow rate | Comparison with a reference meter; Volumetric transfer | in-house method CAL-003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of piston meters with calibration and measurement capability of - 0.7 % of reading from 1 L/min to 20 L/min |
ISO/IEC 17025 (2017)
Environment
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis for physical and chemical characteristics | Air - Ambient | Nitrogen - Oxidised | Calculation; Chemiluminescence | AS 3580 5.1 |
Carbon monoxide | Direct reading instrument | AS 3580 7.1 | ||
Sulfur dioxide | Direct reading instrument | AS 3580 4.1 | ||
Light scattering | Nephelometry | AS/NZS 3580 12.1 | ||
Particulate matter - PM10; Particulate matter - PM2.5 | Tapered element oscillating microbalance (TEOM) | AS/NZS 3580.9.13 (Dichot TEOM with FDMS) | ||
Particulate matter - PM2.5 | Beta attenuation monitors | AS/NZS 3580 9.12 | ||
Ozone | Direct reading instrument | AS 3580 6.1 | ||
Particulate matter - PM10 | Tapered element oscillating microbalance (TEOM) | AS 3580 9.8 | ||
Particulate matter - PM10 | Beta attenuation monitors | AS/NZS 3580 9.11 | ||
Particulate matter - PM10 | Tapered element oscillating microbalance (TEOM) | AS/NZS 3580.9.16 (TEOM with FDMS) | ||
Meteorological monitoring | Atmosphere | Pressure | Direct reading instrument | AS/NZS 3580 14 (Section 6) |
Precipitation | Direct reading instrument | AS/NZS 3580 14 (Section 7) | ||
Relative humidity (RH) | Direct reading instrument | AS/NZS 3580 14 (Section 4) | ||
Solar radiation | Direct reading instrument | AS/NZS 3580 14 (Section 5) | ||
Temperature | Direct reading instrument | AS/NZS 3580 14 (Section 3) | ||
Wind direction; Wind speed - Horizontal | Ultrasonic anemometer | AS/NZS 3580 14 (Section 2) | ||
Sample collection | Air - Ambient | Not applicable | High volume air sampler (HVAS) | Total suspended particulates (TSP) using AS/NZS 3580.9.3 |
Not applicable | Filter paper; Low volume air sampler (LVAS) | AS 3580 9.10 (Particulates PM2.5); AS/NZS 3580 1.1 (Site selection for ambient station) |