National Association of Testing Authorities, Australia
Scope of Accreditation
Arpels Pty Ltd
Site
CMM Technology and Breathalyser Compliance Testing
Accreditation No.
18743
Site No.
20821
Date of Accreditation
27 Jun 2013
Contact
Availability
Services available to external clients
Scope of Accreditation
Withdrawn 17 Jun 2025
Voluntary
CMM Technology and Breathalyser Compliance Testing
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Breath alcohol instruments | Alcosense precision; Alert J5; BTA-30-DAS; Breath alcohol instruments; Drager 3820; Drager 5510; Drager 5820; Drager 6510; Drager 6810; Drager 6820; Drager 7510; Lifeguard breathalyser; Lifeloc FC10; Lifeloc FC10 Plus; Lifeloc FC20; Lifeloc FC5; Lion Alcoblow; Lion SD400; Lion SD500 | Alcohol content | Direct measurement against a reference standard | 0.000-0.100g/210L of simulated blood alcohol content; 0.000-0.100g/230L of simulated blood alcohol content | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.009g/210L above 0.000 up to 0.100g/210L 0.009g/230L above 0.000 up to 0.100g/230L | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Breath alcohol instruments | Alcohol content | Direct measurement against a reference standardWet gas/Dry gas simulation | AS3547:1997 sections 3 and 4; Appendices B, C and D; supplementary in-house method Testing to AS3547:1997 - Type 2 Devices and Testing to AS3547:1997 - Type 3 Devices; By methods based on NMI R126 | 0.000-0.100g/210L of simulated blood alcohol content; 0.000-0.100g/230L of simulated blood alcohol content | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.009g/210L above 0.000 up to 0.100g/210L; 0.009g/230L above 0.000 up to 0.100g/230L |
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Pattern approval and physical performance evaluation of metering and trade measurement equipment | Breath alcohol instruments | Performance tests | Wet gas simulation | AS 3547:1997 Appendices B, C, D | Type 2 and Type 3 devices |
Breathalyser Compliance Testing
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Pattern approval and physical performance evaluation of metering and trade measurement equipment | Breath alcohol instruments | Performance tests | Wet gas simulation | AS 3547:1997 Appendices B, C, D | Type 2 and Type 3 devices |
CMM Technology
ISO/IEC 17025 (2017)
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Breath alcohol instruments | Breath analysers | Alcohol content | Direct measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.0041 g/210 L from 0.000 up to 0.050 g/210 L 0.008 g/210 L above 0.050 up to 0.100 g/210 L 0.009 g/230 L from 0.000 up to 0.100 g/230 L |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
18743
Site No.
20821
Print date
18 Jun 2025
END OF SCOPE