Coops Drainage and Civil Pty Ltd

Site

Coops Drainage and Civil

Accreditation No.

15304

Site No.

15937

Date of Accreditation

15 Dec 2005

Address

243A Burnside Road
Stapylton, QLD 4207
Australia

coops.com.au

Contact

Ms Penny Intaraphim P: +61 (07) 32871844

Availability

Services available to external clients

Scope of Accreditation

Coops Drainage and Civil

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of water and sewer pipelines Sewer maintenance chamber structures; Sewer pipelines Pneumatic pressure; Vacuum pressure Not applicable AS 2419.1 Appendix S.4.2 Test 2, S.5.1 Test 3, S.5.2 Test 4,
AS/NZS 3500.2 clause 15.3 & 15.4,
WSA 02 clause 21.4.2.1, 21.4.2.2,
WSA 02-SEQ Edition- cl 21.4.5.2,
WSA 06 Section 41.4
Vacuum testing: 0  to -100 kPa
Pneumatic testing: 0 to 100kPa
Sewer pipelines Ovality Not applicable WSA 02- SEQ Edition - clause 21.6, Up to 300 mm
Sewer pipelines; Water pipelines Hydrostatic pressure; Leakage Not applicable AS/NZS 2566.2 Section 6.3.4.1 Method M4,
AS/NZS 2566.2 Section 6.3.4.2 Method M5,
AS/NZS 3500.1 Section 17.3.1
Leakage testing in the range:
444L/h - 4500L/h up to 2500 kPa
For determining compliance with:
Water Services Association of Australia WSA 03 Section 19.4

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.