Cameron Services International Pty Ltd

Site

Darwin Facility

Accreditation No.

14340

Site No.

22097

Date of Accreditation

16 May 2014

Address

23 Dawson Street
East Arm, NT 822
Australia

cameron.slb.com

Contact

Mr Mark Fraser P: +61 0411224670

Availability

Services available to external clients

Scope of Accreditation

Darwin Facility

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Hydrostatic pressure Not applicable ISO 1402, Clauses 7 and 8.1 Up to 150 MPa;
Including on-site testing
Piping Pneumatic pressure Not applicable ASME B31.1, Chapter VI, Section 137.5;
ASME B31.3, Chapter VI, Section 345;
AS 4041, Subclauses 6.6, 6.8.1, 6.9
Up to 150 MPa;
Including on-site testing
Hydrostatic pressure Not applicable ASME B31.1, Chapter VI, para. 137.4;
ASME B31.3, Chapter VI, para. 345;
AS 4041, Subclauses 6.6, 6.7 and 6.9
Up to 150 MPa;
Including on-site testing
Pressure fittings Pneumatic pressure Not applicable API STD 6DX, Subsection 12.2 Up to 150 MPa;
Including on-site testing
Pressure vessels Pneumatic pressure Not applicable AS 1210, Subclause 5.11;
AS 4037, Clause 18
Up to 150 MPa;
Including on-site testing
Hydrostatic pressure Not applicable AS 1210, Subclause 5.10;
AS 4037, Clause 17;
ASME BPVC Section VIII Division 1, para. UG-99;
ASME BPVC Section I, para. PG-99
Up to 150 MPa;
Including on-site testing
Valves Hydrostatic pressure Not applicable ANSI/FCI 70-2;
API SPEC 6A, Subsections 11.1 and 11.2;
ANSI/ISA-75.19.01;
API SPEC 6D, Section 10, Subsections I.5 and I.7;
API SPEC 6DSS, Subsections 10.1, 10.2, 10.3, 10.5, 10.6 and L.3;
API STD 526, Section 9;
API STD 527, Section 4,
API RP 576, Subsections 6.4.4.7, 6.4.4.8, 6.4.4.13, 6.4.4.14 and A.3;
API STD 598, Sections 5 and 6;
AS 1271, Subclauses 2.6 and 3.4;
ASME B16.34 Section 7,
ASME BPVC Section I, para. PG-73.5;
BS EN 12266-1;
ISO 4126-4, Subclause 6.3;
ISO 5208, Clause 4;
MSS SP-61
Up to 150 MPa;
Including on-site testing
Pneumatic pressure Not applicable ANSI/FCI 70-2;
API SPEC 6A, Subsections 11.1 and 11.3;
API SPEC 6D, Subsections I.8 and I.9;
API SPEC 6DSS, Subsections 10.1, 10.2, 10.8, 10.9,10.10, 10.11,10.14 and L.3;
API STD 526, Section 9;
API STD 527, Sections 2 and 5;
API RP 576, Subsections 6.4.3.2, 6.4.4.7, 6.4.4.8, 6.4.4.13, 6.4.4.14 and A.2;
API STD 598, Sections 5 and 6;
API STD 2000, Subsection 5.4;
AS 1271, Subclause 3.4;
ASME BPVC Section I, para. PG-73.5;
BS EN 12266-1;
ISO 4126-4, Subclauses 6.4 and 6.6;
ISO 5208, Clause 4;
ISO 28300, Subclause 6.4;
MSS SP-61
Up to 150 MPa;
Including on-site testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.