Dynaflow Pty Ltd

Site

Dynaflow SA

Accreditation No.

2910

Site No.

15131

Date of Accreditation

22 Jan 2003

Address

Unit 2 No 8 William Street
Norwood, SA 5067
Australia

dynaflow.com.au

Contact

Availability

Services available to external clients

Scope of Accreditation

Dynaflow SA

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Biological safety cabinets Inward air velocity Cold DOP AS 1807.21 (2000)
AS 1807 Clause 4.8
For compliance with
 AS 2252.1 (2002)
Illuminance Not applicable AS 1807.15 (2000)
AS 1807 Clause 4.5
For compliance with
AS 2252.1 (2002)
AS 2252. 2
Ultraviolet intensity Not applicable AS 1807.23 (2000)
AS 1807 Clause 4.10
For compliance with
 AS 2252.1 (2002)
Integrity of HEPA filter installations Cold DOP AS 1807.6 (2000)
AS 1807 Clause 4.4
For compliance with
 AS 2252.1 (2002)
 AS 2252.2
Sound level Face velocity AS 1807.20 (2000)
AS 1807 Clause 4.7
For compliance with
 AS 2252.1 (2002)
Air velocity and uniformity of air velocity Cold DOP AS 1807.1 (2000)
AS 1807 Clause 4.1
For compliance with
AS 2252.1 (2002)
AS 2252.2
Air barrier containment Cold DOP AS 1807.22 (2000)
AS 1807 Clause 4.9
For compliance with
AS 2252. 2
Clean workstations Integrity of HEPA filter installations Cold DOP AS 1807.6 (2000)
AS 1807 Clause 4.4
For compliance with
 AS 2252. 6
Work zone integrity Cold DOP AS 1807.5 (2000)
AS 1807 Clause 4.3
For compliance with
 AS 2252. 6
Sound level Not applicable AS 1807.20 (2000)
AS 1807 Clause 4.7
For compliance with
 AS 2252.6
Ultraviolet intensity Not applicable AS 1807.23 (2000)
AS 1807 Clause 4.10
For compliance with
 AS 2252.6 
Work zone integrity Not applicable

AS 1807.20 (2000)

AS 1807 Clause 4.3

For compliance with 
AS 2252. 6 
Illuminance Not applicable AS 1807.15 (2000)
AS 1807 Clause 4.5
For compliance with
AS 2252. 6
Air velocity and uniformity of air velocity Cold DOP AS 1807.1 (2000)
AS 1807 Clause 4.1
For compliance with
 AS 2252.6
Fume cupboards and recirculating fume cabinets Sound level Not applicable AS 1807.20 (2000)
AS 1807 Clause 4.7
For compliance with
 AS/NZS 2243.8
AS/NZS 2243.9
Extraction performance Face velocity

AS/NZS 2243.8 Appendix B

AS/NZS 2243.9 Appendix B

For compliance with
AS/NZS 2243.8
AS/NZS 2243.9
Extraction performance Smoke visualisation AS/NZS 2243.8 Appendix A
AS/NZS 2243.9 Appendix A
For compliance with
AS/NZS 2243.8
AS/NZS 2243.9
Illuminance Not applicable AS 1807.15 (2000)
AS 1807 Clause 4.5
For compliance with
AS/NZS 2243.8
AS/NZS 2243.9

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.