National Association of Testing Authorities, Australia
Scope of Accreditation
EMC Bayswater Pty Ltd
Site
EMC Bayswater Pty Ltd
Accreditation No.
18553
Site No.
20485
Date of Accreditation
09 May 2011
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Assessment of emissions and immunity - EMC emission standards | Aerospace and military grade equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | MIL-STD-461D, E and F methods CE101, CE102, RE101 and RE102 | |
Audio, video, audio-visual and entertainment lighting control apparatus for professional use | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable | EN 55103-1 | Excluding testing of harmonics and flicker with products >16 Amps mains supply | |
Electrical and electronic products | Mains harmonics and flicker | Not applicable |
AS/NZS 61000.3.2 ; EN 61000-3-2 ; AS/NZS 61000.3.3 ; EN 61000-3-3 |
||
Electrical and electronic products; Information technology equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
ANSI C63.4: 2014 for unintentional emitters ; ANSI C63.10: 2013 for intentional radiators ; Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; Intentional radiators described in FCC part 15, Subpart C using ANSI C63.4-2014 and ANSI C63.10-2013 ; KDB Guidelines : KDB 789033 D02, KDB 558074 D01, and KDB 905462 ; KDB 447498D01 ICES-003 ; RSS-210 ; RSS-247 ; RSS-GEN |
Radiated Measurements conducted at 3 metre iOATS Semi Anechoic Chamber at Croydon South, Victoria Frequency range of 9 kHz to 40 GHz |
|
Electrical and electronic products; Power tools - Electric | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS CISPR 14-1, CISPR 14-1 and EN 55014-1 | ||
Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable | EN 50270 | ||
Electrical equipment for measurement, control and laboratory use | Conducted emissions; Conducted interference | Not applicable | AS/NZS CISPR 11;CISPR 11; EN 55011 | excluding measurements below 9 kHz | |
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable | IEC 61326-1; EN 61326-1 | |||
Electrical lighting and similar equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS CISPR 15, CISPR 15 and EN 55015 | ||
In-vitro diagnostic (IVD) medical equipment | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable | IEC 61326-2-6; EN 61326-2-6 | ||
Industrial environments | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable |
AS/NZS 4251.1 ; AS/NZS 4251.2 ; AS/NZS 61000.6.4 ; EN 61000-6-4 ; IEC 61000-6-4 |
||
Industrial, scientific and medical (ISM) radio-frequency equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
AS/NZSCISPR 11 ; CISPR 11 ; EN 55011 ; ICES-001 ; CAN/CSA-CEI/IEC CISPR 11 |
excluding measurements below 9 kHz | |
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS CISPR 25 and CISPR 25 | |||
Information technology equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
AS/NZS CISPR 22 ; CISPR 22 ; EN 55022 ; ICES-003 ; CAN/CSA-CEI/IEC CISPR 22 |
||
Information technology equipment; Multimedia equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS CISPR 32, CISPR 32 and EN 55032 | ||
Machine tools | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
AS/NZS CISPR 11, CISPR 11, EN 55011 |
excluding measurements below 9 kHz | |
Medical electrical equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
IEC 60601-1-2 ; EN 60601-1-2 |
||
Radio equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS 4268 | ||
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS 4268 | in the frequency range 9 kHz to 40 GHz | ||
Conducted and radiated emissions; Conducted emissions; Radiated emissions; Radiated interference | Not applicable |
ETSI EN 300 328 |
all tests applicable to transmitters with output power of less than and including 10 dBm EIRP | ||
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable |
ETSI EN 301 489-1 |
|||
Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
EN 50121-3-2 EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8] |
||
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable | EN 50121-4 | ||
Residential, commercial and light industrial environments | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable |
AS/NZS 61000.6.3 ; EN 61000-6-3 ; IEC 61000-6-3 ; BS EN 50491-5-2 ; |
||
Road traffic signal systems and devices | Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference | Not applicable |
EN 50293 EN 50556 clause 6.7 |
||
Shielded enclosures | Attenuation performance | Not applicable |
MIL-STD-285 IEEE Std 299 |
||
Sound and television broadcast receivers and associated equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable | AS/NZS CISPR 13, CISPR 13 and EN 55013 | ||
Vehicles, boats and internal combustion engine driven equipment | Conducted emissions; Conducted interference; Radiated emissions; Radiated interference | Not applicable |
AS/NZS CISPR 12 ; CISPR 12 ; EN 55012 ; EN 55025 ; UN Regulation No. 10 (E/ECE/324/Add.9) : Clauses 6.5, 6.6, 6.7, 6.8 (free field testing method and bulk current injection - BCI method only) and clause 6.9 only. |
excluding insertion loss of ignition noise suppressors | |
Assessment of emissions and immunity - EMC immunity standards | Aerospace and military grade equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | MIL-STD-461 D, E and F methods CS 101, CS 106, CS 109, CS 114, RS 101 and RS 103 | |
Audio, video, audio-visual and entertainment lighting control apparatus for professional use | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 55103-2 | ||
Automotive components and modulesRoad vehicles - component test method for electrical disturbances from narrowband radiated electromagnetic energy | Radiated susceptibility | Not applicable | ISO 11452-2 | ||
Conducted susceptibility | Bulk cable injection | ISO 11452-4 | |||
Components of fire, intruder and social alarm systems | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50130-4 | ||
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity | Not applicable | EN 50130-4 [excluding testing using EN 61000-4-20 methodology] | Excluding testing using EN 61000-4-20 methodology | ||
Electrical and electronic products | Radiated radio-frequency | Not applicable |
IEC 61000-4-3 ; EN 61000-4-3 ; AS/NZS 61000.4.3 |
||
Voltage fluctuations; Voltage short dips and interruptions | Not applicable |
EN 61000-4-11 ; IEC 61000-4-11 ; AS/NZS 61000.4.11 ; IEC 60335-1 Section 19.11.4.6 |
For appliances having a rated current not exceeding 16 A | ||
Surge immunity | Not applicable |
EN 61000-4-5 ; IEC 61000-4-5 ; AS/NZS 61000.4.5 ; IEC 60335-1 Section 19.11.4.4 |
|||
Electrostatic discharge | Not applicable |
EN 61000-4-2 ; IEC 61000-4-2 ; AS/NZS 61000.4.2 ; IEC 60335-1 Section 19.11.4.1 |
|||
Electrical fast transient | Not applicable |
EN 61000-4-4 ; IEC 61000-4-4 ; AS/NZS 61000.4.4 ; IEC 60335-1 Section 19.11.4.3 |
|||
Conducted disturbance; Induced signal susceptibility | Not applicable |
EN 61000-4-6 ; IEC 61000-4-6 ; AS/NZS 61000.4.6 ; IEC 60335-1 Section 19.11.4.5 |
|||
Power frequency magnetic field | Not applicable |
EN 61000-4-8 ; IEC 61000-4-8 ; AS/NZS 61000.4.8 |
|||
Pulsed magnetic field | Not applicable |
EN 61000-4-9 ; IEC 61000-4-9 ; AS/NZS 61000.4.9 ; |
|||
Electrical and electronic products; Information technology equipment; Radio equipment; Telecommunication network equipment | Radiated radio-frequency | Not applicable |
IEC 61000-4-3; EN 61000-4-3 ; AS/NZS 61000.4.3 ; IEC 60335-1 Section 19.11.4.2 |
||
Electrical and electronic products; Power tools - Electric | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 55014-2; AS/NZS CISPR 14-2, CISPR 14-2 | ||
Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50270 | ||
Electrical equipment for measurement, control and laboratory use | Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50270 | ||
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61326-1; IEC 61326-1 | |||
Electrical lighting and similar equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61547 | ||
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity | Not applicable | EN 55103-2 | |||
Electrical relays; Measuring relays and protection equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | IEC 60225-22-6 | ||
Gaming machines | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | AS/NZS GMNS clauses 2.3.52 to 2.3.59 | ||
In-vitro diagnostic (IVD) medical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61326-2-6; EN 61326-2-6 | ||
Industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 61000-6-2, AS/NZS 61000.6.2, IEC 61000-6-2 | ||
Information technology equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | AS/NZS CISPR 24; CISPR 24; EN 55024 | ||
Information technology equipment; Multimedia equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | CISPR 35; EN 55035 |
Excluding Broadband impulsive conducted disturbances test |
|
Machine tools | Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity | Not applicable | EN 50370-2 | ||
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50370-2 | |||
Medical electrical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | IEC 60601-1-2, EN 60601-1-2 | ||
Radio equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | ETSI EN 301 489-1 | ||
Railway electronic equipment used on rolling stock | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50155 Clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8] | ||
Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50121-3-2 | ||
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable | EN 50121-4 | ||
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Radiated susceptibility | Not applicable |
EN 50121-3-2 EN 50121-4 EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 & 12.2.8] |
|||
Residential, commercial and light industrial environments | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions | Not applicable |
EN 61000-6-1 ; AS/NZS 61000.6.1 ; IEC 61000-6-1 ; EN 50491-5-2 |
||
Road traffic signal systems and devices | Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity | Not applicable |
EN 50293 EN 50556 clause 6.7 |
||
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage short dips and interruptions; Voltage spikes | Not applicable |
EN 50293 EN 50556 clause 6.7 |
|||
Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessment | Antennas; Broadcast and telecommunication equipment installations; Hand held and wireless communication devices | Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields; Radiated field strength measurements | Not applicable |
Canadian Standard RSS-102 (RF Exp) MEAS, RSS-102 (NS) MEAS (for external fields only and excluding SAR Measurements) |
(for external fields only and excluding SAR Measurements) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
18553
Site No.
20485
Print date