HRL Technology Group Pty Ltd

Site

Engineering Audits

Accreditation No.

561

Site No.

16028

Date of Accreditation

01 Jul 2005

Address

Unit 4, 677 Springvale Road
Mulgrave, VIC 3170
Australia

hrlt.com.au

Contact

Mr Richard Odgers P: +61 (03) 95659930

Availability

Type A Inspection Body

Scope of Accreditation

Engineering Audits

ISO/IEC 17020 (2012)

Infrastructure and Asset Integrity

Service Product Determinant Procedure Limitations
Pressure plant, pipelines and equipment - Design verification Boilers; Fired pressure vessels; Gas cylinders; Pressure piping; Unfired pressure vessels Design verification Covering standards, codes and specifications addressing the service, including AS 2030, AS 3920, AS 4041, AS 4343, AS/NZS 1200 (also covers relevant ASME Codes), EN 12953 (excluding CE mark provisions), EN 13445 (excluding CE mark provisions), EN 286.1, EN 286.2, EN 286.3, EN 286.4 and NZ Code of Practice

Hazard levels: A, B, C, D, E

Modelling using AS 1210 for finite element analysis of pressure equipment designs

Covering the Churchill (Vic), Mulgrave (Vic) and Coopers Plains (Qld) offices
Pressure plant, pipelines and equipment - Fabrication inspection Boilers; Fired pressure vessels; Pressure piping; Unfired pressure vessels Fabrication inspection Covering standards, codes and specifications addressing the service, including AS 1210, AS 3920, AS 4037, AS 4041, AS 4458, AS 1228, EN 286.1, EN 286.2, EN 286.3, EN 286.4

Hazard levels: A, B, C, D, E

Covering the Churchill (Vic), Mulgrave (Vic) and Coopers Plains (Qld) offices
Pressure plant, pipelines and equipment - In-service inspection Auxiliary vessels; Boilers; Buried or mounded pressure equipment; Compressed air containing vessels; Fired heaters or convection banks; Pressure piping; Pressure relief devices; Process vessels; Static low temperature vessels - Below -10°C; Static storage vessels; Steam pressure vessels; Vessels with quick actuating closures; Water heaters In-service inspection Covering standards, codes and specifications addressing the service, including AS/NZS 3788 Covering the Churchill (Vic), Mulgrave (Vic) and Coopers Plains (Qld) offices
Boilers; Pressure piping In-service inspection Assessed for operation to WTIA Guidance Note 15 (GN - 15 Replication and in-situ Metallography) Covering the Churchill (Vic), Mulgrave (Vic) and Coopers Plains (Qld) offices
Pressure plant, pipelines and equipment - Inspection Pipes and hoses; Pressure equipment Witnessing of hydrostatic tests Covering standards, codes and specifications addressing the service, including AS 4037 Section 17 Covering the Churchill (Vic), Mulgrave (Vic) and Coopers Plains (Qld) offices

Capability

Including Witnessing of Leak tests

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.