Fastlab Calibration Laboratory

Accreditation No.

5473

Site No.

5466

Date of Accreditation

07 Nov 1994

Address

26 Business Park Drive
Notting Hill, VIC 3168
Australia

ecefast.com.au

Contact

Mr Phong Nguyen P: +61 (03) 95388169

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Temperature metrology - Ancillary temperature measuring equipment Process calibrators Resistance to temperature conversion; Volt to temperature conversion Direct measurement by electrical input

Capability

In the range -196°C to 1300°C
Including on site calibrations
With Calibration and Measurement Capability of-
 0.2°C + 0.01% of reading from -196°C to 1300°C
Type J extension wire; Type K extension wire; Type N extension wire; Type R extension wire; Type S extension wire; Type T extension wire Volt to temperature conversion Direct measurement by electrical input

0ºC to 50ºC

Capability

With Calibration and Measurement Capability of-

0.2°C + 0.1% T in the range from 0°C to 50°C
Temperature metrology - Humidity measuring equipment Hygrometers; Psychrometers; Relative humidity sensors Relative humidity (RH) Comparison with a reference standard

Capability

With Calibration and Measurement Capability of-
 In the range from 10%RH to 95%RH from 20°C to 90°C

2.0%RH from 20°C to 50°C
2.8%RH above 50°C to 90°C

Temperature metrology - Non-contact temperature measuring equipment Radiation pyrometers; Thermal imaging systems Temperature Comparison with a reference standard; Direct measurement against a black body source

Capability

With Calibration and Measurement Capability of-
In the range from -30°C to 1200°C

1.5°C from -30°C to 300°C
2.5°C above 300°C to 500°C
3.5°C above 500°C to 1200°C

Temperature metrology - Temperature measuring equipment Base metal thermocouples Temperature Measurement against reference standard


 

Capability

With Calibration and Measurement Capability of-
In the range from -196°C to 1300°C

0.5°C + 0.1% T from -196°C to below -40°C
0.2°C + 0.1% T from-40°C to 650°C
0.2°C + 0.2% T above 650°C to 1300°C

Bimetallic systems Temperature Measurement against reference standard

Capability

With Calibration and Measurement Capability of-
0.5°C in the range from 0°C to 250 °C

Digital temperature measuring systems; Temperature loggers - Single and multi-channel Resistance over oC range; mV over oC range Direct temperature and electrical measurement against reference standard

Capability

In the range -196°C to 1300°C
Including on site calibrations
With Calibration and Measurement Capability of-
 0.2°C + 0.01% of reading from -196°C to 1300°C
Temperature Measurement against reference standard

Capability

With Calibration and Measurement Capability of-
In the range from -196°C to 1300°C
Including on site calibrations

0.25°C from -196°C to below -40°C
0.005°C at 0°C (using RTD sensors)
0.05°C from -40°C to 300°C
0.25°C above 300°C to 650°C
3°C above 650°C to 1300°C

Liquid in glass (LIG) thermometers Temperature Measurement against reference standard

Capability

With Calibration and Measurement Capability of-

0.01°C at 0°C (Icepoint only)

Metallic resistance thermometers Temperature Measurement against reference standard

Capability

With Calibration and Measurement Capability of-
In the range from -80°C to 650°C

0.20°C from -80°C to below -20°C
0.05°C from -20°C to 0°C
0.01°C at 0°C
0.05°C above 0°C to 300°C
0.25°C above 300°C to 650°C 

Surface probes Temperature Measurement against reference standard

Capability

With Calibration and Measurement Capability of-
2.9°C in the range from 0°C to 650°C

Temperature metrology - Temperature standards and reference equipment Dry block calibrators Temperature Direct measurement using a reference standard

Including the methods of -
EA 10/13

Capability

With Calibration and Measurement Capability of-
In the range from -90°C to 1200°C

0.25°C from -90°C to -30°C
0.5°C above -30°C to 650°C
2.5°C above 650°C to 1200°C

Rare metal thermocouples mV per oC Direct measurement using a reference standard

Capability

With Calibration and Measurement Capability of-
In the range from 0°C to 1300°C
 0.2°C + 0.1% T in the range from 0°C to 1300°C
Temperature metrology - Verification of controlled enclosuresincluding on site calibrations Autoclaves and sterilising ovens; Baths; Environmental chambers - Temperature; Freezers; Furnaces; Incubators; Ovens Spatial uniformity; Temperature; Temporal uniformity Direct temperature measurement AS 2853 - 1986

Capability

Including on site calibrations

With Calibration and Measurement Capability of-

In the range from -196°C to 1300°C

0.5°C from -196°C to -40°C
0.25°C above -40°C to 0°C
0.5°C above 0°C to 500°C
2.5°C above 500°C to 1300°C

Environmental chambers - Humidity Humidity By temperature and humidity measurement

Capability

Including on site calibrations

With Calibration and Measurement Capability of-

In the range from 10%RH to 95%RH from 10°C to 90°C

2.5%RH from 10%RH to 95%RH from 10°C to 90°C

Medical refrigeration equipment Spatial uniformity; Temperature; Temporal uniformity Direct temperature measurement AS 3864.2 (excluding clause 3.6.4)

Capability

Including on site calibrations

For the following enclosure types
Blood fridges (upright, single & multi-door, under bench and walk-in rooms) ;
Plasma freezers (ultra-low, upright, chest and walk-in rooms)

With Calibration and Measurement Capability of-

In the range from -196°C to 20°C

0.5°C from -196°C to -40°C
0.25°C above -40°C to 0°C
0.5°C above 0°C to 20°C

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.