Endress + Hauser Australia Pty Ltd

Site

Gas Analyser Calibration Laboratory

Accreditation No.

2246

Site No.

2239

Date of Accreditation

01 Jun 2017

Address

50 Broughton Road,
Artarmon, NSW 2064
Australia

endress.com

Contact

Mr Michael Wagner P: +61 0439437910

Availability

Services conditionally available to external clients

Scope of Accreditation

Withdrawn 28 Oct 2025

Voluntary

Gas Analyser Calibration Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
Chemical metrology - Gas analysers Gas analysers; Mine safety and confined space equipment Concentration Direct measurement by certified reference material in-house method WOS0001

Capability

Calibration in the laboratory or at a customer site (above ground)
With Calibration and Measurement Capability of-
Carbon monoxide - CO (Infra-red): 2.3% of reading over the range 20-5000 part per 106 (ppm)
Carbon monoxide - CO (Electrochemical): 2.3% of reading over the range 1-1000 part per 106 (ppm)
Carbon dioxide - CO2 (Infra-red): 2.3% of reading over the range 0.001-100 %vol/vol
Methane - CH4 (Infra-red): 2.3% of reading over the range 0.01-100 %vol/vol
Nitric oxide - NO (Infra-red): 2.3% of reading over the range 0.0075-100 %vol/vol
Oxygen - O(Paramagnetic): 2.3% of reading over the range 0.01-100 %vol/vol
Oxygen - O2 (Electrochemical): 2.3% of reading over the range 0.01-25 %vol/vol
Sulfur dioxide - SO2 (Infra-red): 2.3% of reading over the range 0.004-100 %vol/vol
Propane - C3H8 (infra-red): 2.3% of reading over the range 0.01-100 %vol/vol 

ISO/IEC 17025 (2017)

Manufactured Goods

Withdrawn
Service Product Determinant Technique Procedure Limitations
Performance evaluation of personnel protection equipment and general ballistic measurements Gas analysers and respirator equipment Carbon dioxide (CO2); Carbon monoxide; Methane; Oxygen; Sulfur dioxide Electrochemical; Infrared (IR); Paramagnetic cell

In-house WOS0001

Calibrated as % V/V or ppm V/V

ISO/IEC 17025 (2017)

Materials

Withdrawn
Service Product Determinant Technique Procedure Limitations
Analysis for chemical composition of gas and aerosols Industrial gas supplies excluding fuels and calibration mixtures Carbon dioxide (CO2); Carbon monoxide; Dinitrogen monoxide (nitrous oxide); Methane; Oxygen; Sulfur dioxide Classical; Electrochemical detector; Infrared (IR); Paramagnetic cell

In-house WOS0001

CO (Infra Red) 0-100%
CO (Electrochemical) 0-100ppm, 0-300ppm, 0-500ppm
CO2 (Infra red) 0-100%
CH4 (Infra red) 0-100%
NO (Infra red) 0-100%
O2 (Paramagnetic) 0-100%
O2 (Electrochemical) 0-100%
SO2 (Infra red) 0-100%





The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.