National Association of Testing Authorities, Australia
Scope of Accreditation
Woodside Energy Ltd
Site
Gas Metering Station
Accreditation No.
2268
Site No.
2261
Date of Accreditation
02 Dec 1987
Address
Withnell Bay, Burrup Peninsula
Karratha, WA 6714
Australia
Contact
Mr Josh Foleti P: +61 (08) 91588637
Availability
Type C Inspection Body
Scope of Accreditation
Gas Metering Station
ISO/IEC 17020 (2012)
Infrastructure and Asset Integrity
Service | Product | Determinant | Procedure | Limitations | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Metering systems - Inspection | Metering systems | Audit; Spot audit; Verification | Determination of flow of mass and energy of natural gas including calibration of instrumentation for measurement of gas pressure, temperature, density and gas composition in accordance with ISO 6976, AGA Report 8 and Woodside Energy Ltd Gas Metering Station Manual as applied to gas delivered to the Dampier to Bunbury Natural Gas Pipeline and the Burrup Extension Pipeline | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Periodic assessment, verification and spot audit of metering systems including -- Metering records and log books; - Procedures; - Personnel; - Metering monitoring systems; - Meters, transmitters and associated computers; - Flow calculations; - Valve operation and integrity; - Gas chromatograph balancing and performance (repeatability, reproducibility and linearity); - Gas pressure, temperature, flow, density and composition measurement; - Sample probes; - Diagnostic and troubleshooting. Considering parameters of: Installation, pressure, temperature, flow, density, composition |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
2268
Site No.
2261
Print date
26 Dec 2024
END OF SCOPE