National Association of Testing Authorities, Australia
Scope of Accreditation
SRG Global Asset Care Pty Ltd
Site
Gladstone NDT Laboratory
Accreditation No.
218
Site No.
1122
Date of Accreditation
17 Jul 1974
Contact
Mr Willie Smuts
P: +61 (07) 48394800
Availability
Services available to external clients
Scope of Accreditation
Gladstone NDT Laboratory
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Limitations |
---|---|---|---|---|
Non-destructive testing (NDT) - Material properties and internal integrity | Bonded metals | Ultrasonic detection and characterisation of discontinuities | A-scan capability; Phased array capability (PAUT) - Manual | |
Castings - Cast irons, steel and alloy steels; Castings - Non-ferrous metals and alloys | Ultrasonic detection and characterisation of discontinuities | A-scan capability; Phased array capability (PAUT) - Manual | ||
Rolled or wrought steel products | Ultrasonic detection and characterisation of discontinuities | A-scan capability; Phased array capability (PAUT) - Manual | ||
Welded joints - Aluminium alloys; Welded joints - Clad and overlaid steel; Welded joints - Copper and copper-nickel alloys; Welded joints - Ferritic materials; Welded joints - Stainless steel, austenitic and duplex materials; Welded joints - Titanium and titanium alloys | Radiographic detection and characterisation of discontinuities | Film radiography | ||
Welded joints - Ferritic materials | Ultrasonic detection and characterisation of discontinuities | A-scan capability; Phased array capability (PAUT) - Manual | ||
Non-destructive testing (NDT) - Product profile and corrosion mapping | Metallic piping; Metallic plate | Ultrasonic material thickness - Spot or grid measurements | Thickness meter | |
Ultrasonic material profiling and characterisation of material loss | A-scan - Manual; Phased array capability (PAUT) - Manual | |||
Non-destructive testing (NDT) - Surface techniques | Metallic surfaces | Magnetic particle detection of discontinuities | AC magnetic flow | |
Dye penetrant detection of discontinuities | Solvent removable; Water washable | |||
Visual detection of discontinuities (prior to initial service) - Rolled products; Visual detection of discontinuities (prior to initial service) - Welded joints | Visual examination |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
218
Site No.
1122
Print date
08 Dec 2023