National Association of Testing Authorities, Australia
Scope of Accreditation
HK Calibration Technologies Pty Ltd
Site
HK Calibration Technologies Pty Ltd-Cheltenham
Accreditation No.
20820
Site No.
25803
Date of Accreditation
06 Jul 2026
Contact
Mr Ayaz Sheik
P: +61 (03) 85130755
Availability
Services available to external clients
Scope of Accreditation
HK Calibration Technologies Pty Ltd-Cheltenham
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Digital multimeters (DMM) | AC current; DC current | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability DC Currentwith a Calibration and Measurement Capability of – 1.1 µA from 0.19 mA to below 3.3 mA 11 µA from 3.3 mA to below 33 mA 0.11 mA from 33 mA to below 330 mA 1.4 mA from 330 mA to below 2.2 A 9.1 mA from 2.2 A to 11 A AC Current 500 Hz to 1 kHz with a Calibration and Measurement Capability of - 45 mA from 2.2 A to 11 A 1 kHz to below 5 kHz with a Calibration and Measurement Capability of - 1.7 µA from 33 µA to below 330 µA 8.0 µA from 330 µA to below 3.3 mA 0.084 mA from 3.3 mA to below 33 mA 0.89 mA from 33 mA to below 330 mA 20 mA from 0.33 A to 2.2 A 5 kHz to below 10 kHz with a Calibration and Measurement Capability of - 5.0 µA from 33 µA to below 330 µA 24 µA from 330 µA to below 3.3 mA 0.24 mA from 3.3 mA to below 33 mA 2.4 mA from 33 mA to 330 mA |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Digital multimeters (DMM); Ohm meters | Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability With Calibration and Measurement Capability of -0.011 Ω from 2 Ω to below 11 Ω 0.021 Ω from 11 Ω to below 33 Ω 0.029 Ω from 33 Ω to below 110 Ω 0.049 Ω from 110 Ω to below 330 Ω 0.20 Ω from 330 Ω to below 1.1 kΩ 0.40 Ω from 1.1 kΩ to below 3.3 kΩ[MN1] 1.8 Ω from 3.3 kΩ to below 11 kΩ 3.9 Ω from 11 kΩ to below 33 kΩ 21 Ω from 33 kΩ to below 100 kΩ 49 Ω from 100 kΩ to below 330 kΩ 0.26 kΩ from 330 kΩ to below 1.1 MΩ 0.60 kΩ from 1.1 MΩ to below 3.3 MΩ 8.2 kΩ from 3.3 MΩ to below 11 MΩ 47 kΩ from 11 MΩ to below 33 MΩ 0.65 MΩ from 33 MΩ to below 110 MΩ 1.7 MΩ from 110 MΩ to 290 MΩ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Digital multimeters (DMM); Voltmeters | AC voltage; DC voltage | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability AC voltage10 Hz to below 45 Hz with a Calibration and Measurement Capability of - 0.15 mV at 30 mV 0.93 mV from 33 mV to below 330 mV 6.0 mV from 330 mV to below 3.3 V 56 mV from 3.3 V to 33 V 45 Hz to below 1 kHz with a Calibration and Measurement Capability of - 0.078 mV at 30 mV 0.21 mV from 33 mV to below 330 mV 2.0 mV from 330 mV to below 3.3 V 18 mV from 3.3 V to below 33 V 0.20 V from 33 V to below 330 V 0.70 V from 330 V to 1000 V 1 kHz to below 10 kHz with a Calibration and Measurement Capability of - 0.078 mV at 30 mV 0.21 mV from 33 mV to below 330 mV 2.0 mV from 330 mV to below 3.3 V 18 mV from 3.3 V to below 33 V 0.31 V from 33 V to below 330 V 1 kHz to below 8 kHz with a Calibration and Measurement Capability of - 2.9 V from 330 V to 1000 V 10 kHz to below 20 kHz with a Calibration and Measurement Capability of - 0.097 mV at 30 mV 0.40 mV from 33 mV to below 330 mV 22 mV from 330 mV to below 3.3 V 34 mV from 3.3 V to below 33 V 20 kHz to below 100 kHz with a Calibration and Measurement Capability of - 0.17 mV at 30 mV 1.1 mV from 33 mV to below 330 mV 19 mV from 330 mV to below 3.3 V 20 kHz to below 90 kHz with a Calibration and Measurement Capability of - 0.11 V from 3.3 V to below 33 V 10 kHz to below 180 kHz with a Calibration and Measurement Capability of - 0.35 V from 33 V to below 330 V 100 kHz to below 450 kHz with a Calibration and Measurement Capability of - 26 mV from 330 mV to 3.3 V DC voltage with a Calibration and Measurement Capability of - 27 µV from 0 mV to below 330 mV 0.20 mV from 0.33 V to below 3.3 V 2.0 mV from 3.3 V to below 33 V 22 mV from 33 V to below 330 V 67 mV from 330 V to 1000 V |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20820
Site No.
25803
Print date
14 Jul 2026