HK Calibration Technologies Pty Ltd

Site

HK Calibration Technologies Pty Ltd- North Parramatta

Accreditation No.

20820

Site No.

24986

Date of Accreditation

06 Jul 2026

Address

3/27 Daking Street
North Parramatta, NSW 2151
Australia

hkcalibrations.com.au

Contact

Mr Marcus Hanif Khan P: +61 1300309881

Availability

Services available to external clients

Scope of Accreditation

HK Calibration Technologies Pty Ltd- North Parramatta

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Digital multimeters (DMM) AC current; DC current Comparison with a reference standard

Capability

DC Current 
with a Calibration and Measurement Capability of –
1.1 µA from 0.19 mA to below 3.3 mA
11 µA from 3.3 mA to below 33 mA
0.11 mA from 33 mA to below 330 mA
1.4 mA from 330 mA to below 2.2 A
10 mA from 2.2 A to 11 A

AC Current
1kHz to below 5 kHz
with a Calibration and Measurement Capability of
1.7 µA from 33 µA to below 330 µA
8.0 µA from 330 µA to below 3.3 mA
0.080 mA from 3.3 mA to below 33 mA
0.89 mA from 33 mA to below 330 mA
20 mA from 0.33 A to 2.2 A
500 Hz to 1 kHz
45 mA from 2.2 A to 11 A
5kHz to below 10 kHz
with a Calibration and Measurement Capability of
5.0 µA from 33 µA to below 330 µA
24 µA from 330 µA to below 3.3 mA
0.23 mA from 3.3 mA to below 33 mA
 2.4 mA from 33 mA to 330 mA
DC and low frequency electrical metrology - Electrical measurement and test equipment Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard

Capability

With Calibration and Measurement Capability of -
0.011 Ω from 2 Ω to below 11 Ω
0.021 Ω from 11 Ω to below 33 Ω
0.029 Ω from 33 Ω to below 110 Ω
0.049 Ω from 110 Ω to below 330 Ω
0.20 Ω from 330 Ω to below 1.1 kΩ
0.40 Ω from 1.1 kΩ to below 3.3 kΩ[MN1]
1.8 Ω from 3.3 kΩ to below 11 kΩ
3.9 Ω from 11 kΩ to below 33 kΩ
21 Ω from 33 kΩ to below 100 kΩ
49 Ω from 100 kΩ to below 330 kΩ
0.30 kΩ from 330 kΩ to below 1.1 MΩ
0.60 kΩ from 1.1 MΩ to below 3.3 MΩ
8.2 kΩ from 3.3 MΩ to below 11 MΩ
47 kΩ from 11 MΩ to below 33 MΩ
0.66 MΩ from 33 MΩ to below 110 MΩ
 1.7 MΩ from 110 MΩ to 290 MΩ  
DC and low frequency electrical metrology - Electrical measurement and test equipment Digital multimeters (DMM); Voltmeters AC voltage; DC voltage Comparison with a reference standard

Capability

AC voltage
10 Hz to below 45 Hz
with a Calibration and Measurement Capability of
0.15 mV from 30 mV to below 33 mV
0.93 mV from 33 mV to below 330 mV6.0 mV from 330 mV to below 3.3 V
56 mV from 3.3 V to 33 V
45 Hz to below 1 kHz
with a Calibration and Measurement Capability of
0.078 mV at 30 mV
0.21 mV from 33 mV to below 330 mV
2.0 mV from 330 mV to below 3.3 V
18 mV from 3.3 V to below 33 V
0.20 V from 33 V to below 330 V
0.70 V from 330 V to 1000 V
1kHz to below 10 kHz
with a Calibration and Measurement Capability of
0.078 mV at 30 mV
0.21 mV from 33 mV to below 330 mV
2.0 mV from 330 mV to below 3.3 V
18 mV from 3.3 V to below 33 V
0.31 V from 33 V to below 330 V
1kHz to below 8 kHz
with a Calibration and Measurement Capability of
3.0 V from 330 V to 1000 V
10 kHz to below 20 kHz
with a Calibration and Measurement Capability of
0.097 mV at 30 mV
0.40 mV from 33 mV to below 330 mV
22 mV from 330 mV to below 3.3 V
34 V from 3.3 V to below 33 V
20 kHz to below 100 kHz 
with a Calibration and Measurement Capability of
0.17 mV at 30 mV
1.1 mV from 33.00 mV to below 330 mV
19 mV from 330 mV to below 3.3 V
20 kHz to below 90 kHz
with a Calibration and Measurement Capability of
0.11 V from 3.3 V to below 33 V
10 kHz to below 180 kHz
with a Calibration and Measurement Capability of
0.35 V from 33 V to below 330 V
100 kHz to below 450 kHz
with a Calibration and Measurement Capability of
26 mV from 330 mV to 3.3 V

DC voltage
with a Calibration and Measurement Capability of -
27 µV from 0 mV to below 330 mV
0.20 mV  from 0.33 V to below 3.3 V
2.0  mV from 3.3 V to below 33 V
22 mV from 33 V to below 330 V
67 mV from 330 V to 1000 V

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.