IKM Measurement Services Australia Pty Ltd

Site

IKM Measurement Services Australia Pty Ltd

Accreditation No.

18795

Site No.

20920

Date of Accreditation

06 Jun 2013

Address

33 Kewdale Road
Welshpool, WA 6106
Australia

ikm.com

Contact

Mr Sean Bourke P: +61 (08) 94526100

Availability

Services available to external clients

Scope of Accreditation

IKM Measurement Services Australia Pty Ltd

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Pressure metrology - Pressure and vacuum measuring equipmentincluding on site calibrations Manometers; Pressure gauges; Pressure recorders; Pressure transducers Gauge pressure Comparison with dead weight tester; Comparison with reference instrument By in-house procedure BL06.08.01 and BL06.05.01

Capability

including on-site calibration

with Calibration and Measurement Capability of -

130 Pa + 0.03% of reading from 0.07 MPa to 260 MPa

Pressure metrology - Pressure standards Pressure calibrators - Non-dead weight Gauge pressure Comparison with dead weight tester By in-house procedure BL06.08.01

Capability

with Calibration and Measurement Capability of -

130 Pa + 0.03% of reading from 0.07 MPa to 260 MPa

Temperature metrology - Ancillary temperature measuring equipmentincluding on site calibrations Transmitters Resistance to temperature conversion; Volt to temperature conversion Direct measurement by electrical input

By in-house procedure BL07.05.01

Capability

including on-site calibration

with Calibration and Measurement Capability of -

0.09 ºC + (0.06 ºC/100 ºC) from -40 ºC to 300 ºC 

Temperature metrology - Temperature measuring equipmentincluding on site calibrations Bimetallic systems; Filled metal systems Temperature Measurement against reference standard

Capability

including on site calibrations
with Calibration and Measurement Capability of -
0.5 ºC from -20 ºC to 120 ºC (bimetallic thermometers)
1.0 ºC from 0 ºC to 100 ºC (filled metal systems)
Digital temperature measuring systems; Temperature loggers - Single and multi-channel Temperature Measurement against reference standard

By in-house procedure BL07.06.01

Capability

including on-site calibration

with Calibration and Measurement Capability of -

0.045 ºC + (0.01 ºC/100 ºC) from -40 ºC to 300 ºC

Torque - Torque measuring and testing equipmentincluding on site calibrations Torque wrenches Torque Comparison with a reference standard

By  in-house procedure BL14.08.02

Capability

including on-site calibration

with Calibration and Measurement Capability of -

0.012 Nm +1% of reading from 1.25 Nm to 25 Nm.
0.6 Nm + 1% of reading from 30 Nm to 1500 Nm.

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Valves Leakage; Pneumatic pressure Not applicable API 527, NS-EN ISO 4126-1, in-house test method BL 06.08.03 including on-site testing
Pressure relief valves/safety valves up to 100 MPa
Hydrostatic pressure; Leakage Not applicable API 527, NS-EN ISO 4126-1, in-house test method BL 06.08.03 including on-site testing
Pressure relief valves/safety valves up to 200 MPa

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.