National Association of Testing Authorities, Australia
Scope of Accreditation
IKM Testing Australia Pty Ltd
Site
IKM Testing Australia Pty Ltd
Accreditation No.
16751
Site No.
18085
Date of Accreditation
30 Jun 2009
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Evaluation of mechanical performance of high pressure oil and gas pipelines | High pressure oil and gas pipelines | Strength, leak and combined pressure evaluation | Not applicable | API RP 17B, Clause 9.5; API SPEC 17J, Section 9; AS 2885.4; DNVGL-ST-F101, Clause 10.10 | Up to 120 MPa |
| Evaluation of mechanical performance of low pressure oil and gas pipelines | Low pressure oil and gas pipelines | Strength, leak and combined pressure evaluation | Not applicable | API RP 17B, Clause 9.5; API SPEC 17J, Section 9; AS 2885.4; AS/NZS 4645.3 Section 6; DNV-ST-F101, Clause 10.10; ISO 13628-11:2007, Clause 11.5 | Up to 120 MPa AS/NZS 4645.3 Section 6 to determine compliance with AS/NZS 2566.2 Section 6.3 and Appendix M |
| Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Electrical continuity | Not applicable | AS 1180.13C-1983 | including on-site testing |
| Hydrostatic pressure | Not applicable | AS 1180.5-1999, Clause 7.1; ISO 1402, Clause 8.1; ISO 10380, Clause 5.3 | up to 300 MPa for workshop testing and up to 150 MPa for on-site testing. | ||
| Electrical resistance | Not applicable | AS 1180.13A-1983; AS 1180.13B-1987 | including on-site testing | ||
| Piping | Pneumatic pressure | Not applicable | AS 4041 Section 6.8; AS 4037 Section 18; ASME B31.3 Section 345 | Up to 69Mpa; including on-site testing | |
| Hydrostatic pressure | Not applicable | AS 4041, Section 6.7; AS 4037, Section 17; ASME B16.5, Section 8; ASME B31.3, Section 345 | Up to 100Mpa; including on-site testing | ||
| Pressure vessels | Pneumatic pressure | Not applicable | AS 4037, Section 18 | Up to 69Mpa; including on-site testing | |
| Hydrostatic pressure | Not applicable | AS 4037, Section 17 | Up to 100Mpa; including on-site testing |
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.
Accreditation No.
16751
Site No.
18085
Print date
23 Sep 2026