SGS Australia Pty Ltd

Site

Industries & Environment (Perth OCM Laboratory)

Accreditation No.

15506

Site No.

15529

Date of Accreditation

17 Feb 2005

Address

28 Reid Road
Perth Airport, WA 6105
Australia

sgs.com

Contact

Mr John Rossi P: +61 (08) 93733500

Availability

Services available to external clients

Scope of Accreditation

Industries & Environment (Perth OCM Laboratory)

ISO/IEC 17025 (2017)

Materials

Service Product Determinant Technique Procedure Limitations
Analysis of biofuels, hydrocarbon fuels and related fuel products Fuel oil Estimated heat of combustion Calculation

ASTM D4868

Fuel oil; Liquid fuels Particle count Particle analyser

ISO 4406

Contaminants Gravimetric

ASTM D5452

Liquid fuels Cloud point Temperature

ASTM IP D2500 219

Pour point Temperature

ASTM IP D97 15

Viscosity - Kinematic Capillary viscometer

ASTM IP D445/71 and ISO 3104

Flash point Pensky-Martens closed cup

ASTM IP D93 34

Analysis of lubricants, oils and related products Base oils Estimated heat of combustion Calculation

ASTM D4868

Electrical insulating oils and compounds Sediment and sludge Gravimetric

AS 1883 appendixA (1992)

Acidity - Total Titration

ASTM D974

Carbon dioxide (CO2); Carbon monoxide; Ethane; Ethene (ethylene); Ethyne (acetylene); Hydrogen; Methane; Nitrogen; Oxygen GC-FID; GC-TCD

ASTM D3612 and IEC 60567

Interfacial tension Tensiometry

ASTM D971 

Polychlorinated biphenyls (PCBs) GC-ECD

ASTM D4059

Sulfur - Corrosive Visual examination

ASTM D1275B

Dielectric breakdown Electrometric

IEC 60156 and AS 1767 2 1

Moisture - Coulometric Calculation; Titration

IEC 60814 and WP 222

2-Acetylfuran; 2-Furaldehyde; 2-Furfalalcohol; 5-Hydroxymethyl-2-furaldehyde; 5-Methyl-2-furaldehyde HPLC

IEC 61198 and in house WI-AU-OGCDWS-PAP-AN-130

Dielectric dissipation factor at 90oC and 50 Hz; Resistivity of transformer insulating oils Electrometric

IEC 60247 

Neutralisation value (acidity) Titration

ASTM D974

Electrical insulating oils and compounds; Greases; Lubricating oils Colour ASTM colour scale; Visual examination

ASTM D1500

Aluminium; Barium; Boron; Calcium; Chromium; Copper; Ferrous wear metal particles - PQ index; Iron; Lead; Magnesium; Manganese; Molybdenum; Nickel; Phosphorus; Potassium; Silicon; Silver; Sodium; Tin; Titanium; Vanadium; Zinc ICP-AES

ASTM D 5185

Density; Viscosity - Kinematic Density meter

ASTM D4052 and ASTM D445

Electrical insulating oils and compounds; Lubricating oils Density; Viscosity - Dynamic; Viscosity - Kinematic Stabinger viscometer ASTM D7042
Greases; Lubricating oils Flash point Pensky-Martens closed cup

ASTM D93

Oxidation stability Rotating pressure vessel oxidation test (RPVOT)

ASTM D2272

Copper corrosion Visual examination

ASTM D130

Viscosity - Dynamic; Viscosity - Kinematic; Viscosity index Calculation

ASTM D445 and ASTM D2270

Water content Karl-Fischer titration

ASTM D4928 and ASTM D6304C

Insolubles Gravimetric

ASTM D4898

Base number Titration

ASTM D2896

Water separation characteristics Visual examination

ASTM D1401

Acid number Titration

ASTM D974; ASTM D664 (Procedure A)

Cloud point Temperature

ASTM D2500

Ash content Gravimetric

ASTM D482

Pour point Temperature

ASTM D97

Foaming Visual examination

ASTM D892

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.